S1 adjustable 

11800-0702-01

 

Page

 

2 / 6 

www.ziehl.de 

  

General Notes 

 
Compliance with the following instructions is mandatory to ensure the functionality and safety of the 
product.  If  the  following  instructions  given  especially  but  not  limited  for  general  safety,  transport, 
storage, mounting, operating conditions, commissioning and disposal / recycling are not observed, 
the product may not operate safely and may cause a hazard to the life and limb of users and third 
parties.  
 
Deviations  from  the  following  requirements  may  therefore  lead  both  to  the  loss  of  the  statutory 
material defect liability rights and to the liability of the buyer for the product that has become unsafe 
due to the deviation from the specifications. 
 

 
 

Display and controls 

 
                                                   LED yellow, switching state 
                                                     I 
 
 
                                                                             Limit adjusts 
 
 
 
 

Application and short description 

Recording of welding currents (mounting at ground wire) for controlling dedusting plants in combination with 
ZIEHL-controls type STW.  
Recording the state of a consumer of electricity (on or off or defective). 
In general, the current-sensor S1 is used where the current-flow is to be detected, with the exact value of the 
current either known from the power consumption of the connected consumer or does not matter for the 
evaluation.  
For evaluation of measuring data in more than 1 cable, these outputs of several current-sensors can be 
connected in parallel (OR-evaluation).

 

 
 
 
 

Overview of functions 

  switching point app. 5 A (option: adjustable 5-30 A) 

  monitoring of AC and DC currents 

  LED for current flow 

  mounting without disconnection of cable possible 

  2 transistor-outputs, swi and -, direct connection to a PLC possible 

  connection to current-relays ZIEHL type STW 

  robust, sealed execution 

  overload capacity: unlimited 

 
 

 

Summary of Contents for S1 adjustable

Page 1: ...t Protection Operating Manual S1 adjustable updated 2019 08 08 Fu S1 adjustable 11800 0702 01 Page 1 6 www ziehl de Detection of current flow in a conductor Table of contents 1 General Notes 2 2 Display and controls 2 3 Application and short description 2 4 Overview of functions 2 5 Connecting diagram 3 6 Detailed Description 3 7 Important Information 3 8 Installation 4 9 Commissioning 4 10 Error ...

Page 2: ...ate I Limit adjusts 3 Application and short description Recording of welding currents mounting at ground wire for controlling dedusting plants in combination with ZIEHL controls type STW Recording the state of a consumer of electricity on or off or defective In general the current sensor S1 is used where the current flow is to be detected with the exact value of the current either known from the p...

Page 3: ...all power supplying this device before working on this device To use the equipment flawless and safe transport and store properly install and start professionally and operate as directed Only let persons work with the equipment who are familiar with installation start and use and who have appropriate qualification corresponding to their function They must observe the contents of the instructions m...

Page 4: ...om monitored cable is too high no current trough monitored cable or current too low supply voltage 24 V DC is missing Sensor misplaced put on the cable and in parallel Output does not switch off Check adjusted limit crosstalk from a current is a neighbouring conductor sensor is in a magnetic field output has internal short circuit defective 11 Technical data Rated supply voltage Us DC 24 V Toleran...

Page 5: ...ature range operation 0 C 50 C transport 25 C 55 C storage 25 C 55 C 70 C max 24 h Altitude Up to 2000 m NN climatic conditions environmental Class EN60721 3 3 3K3 Humidity Damp heat IEC60068 2 30 55 C and 93 r H Vibration Operation IEC 60255 21 1 IEC 60068 2 6 Class 2 Transport IEC 60255 21 1 IEC 60068 2 6 Class 1 Seismic IEC 60255 21 3 Class 1 Shock Operation IEC 60255 21 2 Class 2 Transport IEC...

Page 6: ...0702 01 Page 6 6 www ziehl de 1 5 11 82 92 102 16 5 3 2 12 Disposal Disposal should be carried out properly and in an environmentally friendly manner in accordance with legal provisions 13 Housing Type S1 Dimensions in mm ...

Reviews: