- Level relay 
 

 

 

 
 

   

 

 

 

Summary of Contents for MINIPAN NS43V

Page 1: ...s and Controls Measuring Transducers Grid and Plant Protection Operating Manual NS43V updated 2023 07 11 dr For more information and help about this product please scan the QR Code or choose the follo...

Page 2: ...is mandatory to ensure the functionality and safety of the product If the following instructions given especially but not limited for general safety transport storage mounting operating conditions co...

Page 3: ...vels For adaptation to the conductivity of the liquid the switching threshold can be set in the range of 5k 250k Thus for example it is possible to distinguish between the liquid itself and foam above...

Page 4: ...run The level is regulated between the electrodes E2 and E3 In the case of outflow control the valve is controlled by relay K2 In the case of inflow control the valve is controlled by relay K3 The re...

Page 5: ...the inflow quantity is greater than the outflow quantity the level around the electrode E3 will be adjusted If the inflow quantity is smaller than the outflow quantity the level around the electrode...

Page 6: ...nd reports the overflow The level is regulated between the electrodes E1 E2 and E3 The outflow valve is controlled by relay K1 between the electrodes E1 and E2 The inflow valve is controlled by relay...

Page 7: ...has elapsed The adjustable time d relay delays the relays when energizing and when de energizing connection plan Function Pr 5 Four times single level monitoring relay ON when electrode is immersed R...

Page 8: ...11880 0703 00 Page 8 12 www ziehl de Pr 6 Swimming pool controller for overflow pool connection plan Function a Filter release b Filter forced shutdown c Hydraulic shut off valve EIN d Fresh water inf...

Page 9: ...y or the responsible representative In order to maintain this status you must observe the safety regulations entitled caution in this operating manual Failures to follow the safety regulations can res...

Page 10: ...sually be corrected in both cases by selecting a less sensitive setting turn Poti Rliquid to the left When the device is switched on or when the program is changed the following is displayed by rapid...

Page 11: ...L Mechanical contact life 3 x 107 operations Electrical contact life 1 x 105 operations at 240 V 6 A Factor of reduction at cos cos 0 3 0 5 Testing conditions EN 50178 Rated impulse voltage 4000 V Ove...

Page 12: ...r snap mounting 7 for fixing to wall with screws 4 2 mm 4 latch for sealing 12 Disposal Disposal should be carried out properly and in an environmentally friendly manner in accordance with legal provi...