Page 1: ...Operating Instruction 200A AC Mini Clamp on Meter ZI 9941 ...
Page 2: ... on the LCD Display rate 2 readings second nominal Battery Two 1 5V AAA batteries Low Battery indication BATT displayed on the LCD Auto OFF Approx 7 minutes Operating conditions 32º F to 86º F 0º C to 30º C 90 RH 86º F to 104º F 30º C to 40º C 75 RH 104º F to 122º F 40º C to 50º C 45 RH Storage conditions 14º F to 140º F 30º C to 60º C 90 Relative Humidity Altitude Operate at less than 3000 meters...
Page 3: ... 0 8 digits 200A 100mA Non Contact AC Voltage 100VAC to 600VAC 50 60Hz Meter Description 1 Current sense jaw 2 Flashlight button 3 Rotary function switch 4 Data HOLD key 5 LCD display 6 Clamp trigger 7 MAX HOLD key 8 Non contact AC voltage indicator light 9 Non contact AC voltage detector probe tip ...
Page 4: ...w should be carefully followed for safe operation 1 NEVER apply voltage or current to the meter that exceeds the specified maximum 2 USE EXTREME CAUTION when working with voltages greater than 25VAC rms These voltages are considerd a shock hazard 3 NEVER operate the meter unless the back cover and the battery fuse door are in place and fastened securely Input Limits Function Maximum Input AC Curre...
Page 5: ...ch to the ACA range 2 Press the jaw trigger and clamp around fully enclosing a single conductor Do not allow a gap between the two halves of the jaw Refer to the diagram at right for the correct way to enclose a single conductor 3 Read the ACA value on the LCD ...
Page 6: ...ty Static electricity or other sources of energy may randomly trip the sensor This is normal operation Flashlight Press and hold the top button to turn the flashlight on Release the button to turn the flashlight off Data Hold To freeze the current reading on the LCD press the Hold Backlight key The word HOLD will appear on the LCD while the meter is in the Data Hold mode To release the Data Hold f...
Page 7: ...MAX hold button was pressed Press the MAX hold button again to return to normal operation Auto Power OFF The auto off feature will turn the meter off after 7 minutes Battery Replacement 1 When the low battery symbol appears on the LCD the batteries must be replaced 2 Power down and remove the rear battery compartment Phillips screw 3 Lift off the battery compartment cover and replace the two 1 5V ...