System features
zNID 24xx Series Configuration Guide
39
System log
The zNID 24xx supports the system log feature as defined in RFC 5424. The
zNID 24xx supports all 8 message severities:
The parameter,
Log Level
, determines what messages will be stored in the
system log. Any message equal to or greater in priority to the log level setting
will be stored in the syslog. The parameter,
Display Level
, determines what
messages are displayed on the web or the CLI. The parameter,
Mode
,
determines where the messages will be stored. The local messages can be
stored in RAM, or they can be stored in a file for later review, or they can be
sent to a remote syslog server. Only one remote server is allowed. The priority
of the messages is selected by a separate parameter.
Figure 17: Configuring the system log
Table 4: System log message severity levels
Message severity
Description
0
Emergency: system is unusable
1
Alert: action must be taken immediately
2
Critical: critical conditions
3
Error: error conditions
4
Warning: warning conditions
5
Notice: normal but significant condition
6
Informational: informational messages
7
Debug: debug-level messages
Summary of Contents for zNID-GE-2402
Page 12: ...About This Guide 12 zNID 24xx Series Configuration Guide ...
Page 18: ...zNID 24xx Series 18 zNID 24xx Series Configuration Guide ...
Page 84: ...Management 84 zNID 24xx Series Configuration Guide Figure 57 View audit log ...
Page 199: ...VLANS zNID 24xx Series Configuration Guide 199 Figure 157 Configuration of VLAN settings ...
Page 208: ...Configuration 208 zNID 24xx Series Configuration Guide ...
Page 220: ...Troubleshooting tests 220 zNID 24xx Series Configuration Guide ...
Page 223: ...Voice zNID 24xx Series Configuration Guide 223 Voice Figure 175 ...
Page 226: ...Index 226 zNID 24xx Series Configuration Guide ...