DT5811 Operator’s Manual 

 
 
 
1.   INTRODUCTION 

This AUTOMOTIVE TESTER is a compact precision, battery operated, LCD 
display 3-½ digits Digital Instrument.. 
Superiority:

 

 

9

 High 

accuracy 

9

 

Digital height 22mm 

9

  Single 30 position rotary switch for FUNCTION and RANGE 

selection, allows fast and convenient operation. 

9

 

Curvilinear mode soft case. 

9

 

Colored indication jack with fully protection test leads. 

9

 

Lower overage power Auto-Power Off 

 

2. GENERAL 

SPECIFICATION 

1)  Display: 3-½ digits LCD with a maximum reading of 1999.   
2)  Measurement rate: updates 2-3/sec. 
3)  Over range indication: “1” figure only in the display 
4)  Automatic negative polarity indication. 
5) The 

” is displayed when the battery voltage drops below the 

operating voltage. 

6)  Full range over load protection. 
7)  Auto Power Off: It will be automatically cut off in about 15 minutes after 

the power is turned on. It needs to be turned off and turned on again to 
continue the power. 

8)  Operating temperature: 0°C~40°C, 0~75% R.H. 

Storage temperature: -10°C~50°C, 0~75% R.H. 

9)  Power: Single standard 9V battery IEC 6F22,NEDA 1604, JIS 006P. 
10) Dimensions: 176L*88W*38Hmm. 
11)  Weight: approx 310g (including battery) 
12)  Accessories: test leads (pair), spare fuse 0.5A piece in case, operator’s 

manual. 

 

3. ELECTRICAL 

SPECIFICATIONS 

Accuracy is given as ± (% of r number of least significant digits) for 
one year, at 23°C±5°C RH<75% 
1) DCV 

R ange

R esolution

A ccuracy

2V

1m V

20V

10m V

200V

0.1V

1000V

1V

±(1.0% +2)

±(0.8% +2)

 

Input impedance: 10M

 on all range 

 
2) ACV 

R ange

R esolution

A ccuracy

2V

1m V

20V

10m V

200V

0.1V

750V

1V

±(1.2% +3)

±(0.8% +3)

 

Input impedance: 10M

                  Frequency range: 40 ~ 400Hz 

 
3) DCA 

R ange

R esolution

A ccuracy

20m A

10uA

±(1.8% +2) 

200m A

0.1m A

±(2.0% +2)

20A

10m A

±(2.0% +10)

 

Measuring voltage drop: 200mV 
 
4) ACA 

R ange

R esolution

A ccuracy

20m A

10uA

±(2.0% +3) 

200m A

0.1m A

±(2.0% +5) 

20A

10m A

±(2.5% +10) 

 

Measuring voltage drop: 200mV          Frequency range: 40 ~ 400Hz 
 
5) OHM 

R ange

R esolution

A ccuracy

200

0.1

±(1.0% ±10)

20K

10

200K

100

20M

10K

±(1.0% ±10)

±(1.0% ±4)

 

6) TEMPERATURE 

 

R ange

R esolution

A ccuracy

-40

 ~  400

±(1.0% +4)

400

 ~ 1000

±(1.5% +15)

1

 

With K-type thermocouple wire 
 
7) DWELL 

 

ANGEL 

R ange

S cope(°)

R esolution

Accuracy

3 C YL

0 ~  120

4 C YL

0 ~  90

5 C YL

0 ~  72

6 C YL

0 ~  60

8 C YL

0 ~  45

0.1°

±(2.0% ±5)

 

 
8) TACHO 

R ange

S cope

R esolution

Accuracy

3 C YL

4 C YL
5 C YL
6 C YL
8 C YL

10 x R P M

±(1.5% ±5)

20000P R M

 

 
4. 

PRECAUTIONS AND PREPARATIONS FOR MEASUREMENT

 

1)  Be sure that battery is correctly placed in the battery case and 

connected to the battery snap. 

2)  Don’t exceed the input limit shown below: 

Function Range

Input terminals

Maximum input

DCV 2~1000V

1000VDC

ACV 2~750V

750VAC

OHM

Diode

DCA 200mA
ACA 200mA

DCA 20A

20A    DC/AC

ACA 20A

20A    DC/AC

A     COM

V

   COM

V

   COM

250V DC/AC

mA       COM

200mA DC/AC

 

3)  Inspect the test leads for damaged insulation or exposed metal. Check 

Test lead continuity. Damaged leads should be replaced. 

4)  Select the proper function and range for your measurement. 
5)  Check the input terminal position for red test lead depends on 

measurement ranges. 

6)  Either one of the test leads should be taken off from the circuit under test 

when changing the test ranges. 

7)  To avoid electrical shock or damage to the meter; Do not apply more 

then 500V between any terminal and earth ground. 

8)  To avoid electronic shock, use caution when working above 60VDC or 

25VAC rms, such voltage pose a shock hazard. 

9)  When finished the measurement, switch off the power. Be sure to 

remove the battery when it is not used for a long time to avoid leakage 
problem. 

10)  Do not tamper with the circuitry to avoid damage. 
11)  Do not use or store the instrument in a place of direct sunlight, high 

temperature and high humidity.

 

 
5. 

METHOD OF MEASUREMENT 

5.1 DCV & ACV MASUREMENT 

1)  Set the Function range switch at the required position. 
2)  Connect black test lead to “COM” terminal and red test lead to the “V

” 

input terminal. 

3)  Connect test leads to measuring point and read the display value the 

polarity of the red lead connection will be indicated at the same time as the 
voltage. 

Note: 

a)  If the voltage to be tested is unknown beforehand, set the Function 

range switch to the highest range and work down. 

b)  When only the figure “1” is displayed over range is being indicated 

and the function range switch has be set to a higher range. 

c)  Never try to measure the voltage above 1000V! Although the 

indication is possible to show, there is danger of damaging the 
internal circuitry. 

 

5.2 DCA & ACA MEASUREMENT 

1)  Connect the black test lead to the “COM” terminal and the red test lead 

to “mA” terminal for a maximum of 0.2A. 

2)  Set the function range switch at the required position. 
3)  Connect test leads to measuring points and read the display value. The 

polarity at the red test lead connection will be indicated at the same time as 
the current. 

Note: 

a)  If the current range is unknown beforehand, set the function range 

Reviews: