Common Control Equipment Installation
32
identifies the acceptable card types for the slots in each cardcage.
Table 3: Model 4048 Card Type/Slot Association
* When installing two channel cages initially, the Aux I/O card(s) should be inserted in
positions 7-12 to provide maximum radio channel capacity and avoid having to rearrange
Aux I/O programming and terminal connections at a later date.
Model 4048 Power Supply
The Model 4048 Power Supply (Part # 950-9693) can operate from either a Universal AC
input or a 12 V
DC
input. The 12 V
DC
source (13.5 V
DC
nominal) has an input range of
11.5 to 15.0 V
DC
. The supply arrives from the factory set to Universal AC operation. To
operate from 12 V
DC
or as a backup supply source, make the jumper selections identified
in
. These jumpers are located on the front panel circuit board, which is accessed
by removing the top cover of the power supply.
Power Supply Connections
The two following tables give the pinouts for the two different types of output cable on a
Model 4048 power supply. The connector part numbers listed in each figure are Zetron
part numbers and are listed for reference only.
950-9867
Dual Channel T/R Control Card (EDACS/Orion)
950-9862
Dual Channel T/R Control Card (iDEN)
950-1091
Dual Channel T/R Control Card (iSpace)
950-0015
Dual Channel T/R Control Card (MAP27)
702-9105
Auxiliary Input/Output Card (AUX I/O)
Cage
Slot
Card Type
Console
1-2
STC only
Console
3-17
CIC only (Positions 1 – 15)
Console
18
CIC (Position 16) or Patch
Channel #1
1-18
Dual Channel (Channels 1 – 36) or AUX I/O
Channel #2
1-6
Dual Channel (Channels 37 – 48)
Channel #2
7-12
AUX I/O only*
Channel #2
13-18
Not Used
Part Number
Card Name
Note
The front panel fault LEDs will not reflect the correct status unless
the jumpers are in the correct position.
Summary of Contents for 4000 Series
Page 1: ...Series 4000 Communication Control System Installation and Configuration 025 9533Y...
Page 6: ...6 025 9533Y...
Page 28: ...Introduction 28 025 9533Y...
Page 88: ...Common Control Equipment Installation 88 025 9533Y Figure 22 Console Duplex Wall Jacks...
Page 110: ...Common Control Equipment Installation 110 025 9533Y...
Page 172: ...Console Installation 172 025 9533Y...
Page 192: ...Audio Level Adjustments 192 025 9533Y...
Page 230: ...Accessory Installation 230 025 9533Y...
Page 236: ...Console ANI Programming 236 025 9533Y...
Page 339: ...339 RSMP Operation Figure 99 Main Screen...
Page 350: ...Radio System Management Program 350 025 9533Y...
Page 362: ...Appendix B Troubleshooting 362 025 9533Y...
Page 418: ...Index 418 025 9533Y...