Configuring Station Transponder Units
60
Serial Port Programming
The Station Transponder Unit will have default settings in it as it comes from the factory.
In many cases these will be sufficient; however, if you intend to use the sense inputs to
trigger relay functions (or need to alter several timer settings), you will need to access the
serial programming mode for setting up the Station Transponder Unit.
In order to carry out serial programming on the Station Transponder Unit, you will need
the following:
• A laptop or desktop computer with a free COM port
• A compatible serial cable (see
• A terminal emulation program, such as Hyper-Terminal
♦
Accessing the Serial Settings of an Station Transponder Unit
1. Connect a compatible serial cable (see
on page 153) between
your computer and socket J1 on the transponder board.
2. Set switch SW1-8 to the ON position.
3. Using a serial terminal emulation program (such as HyperTerminal), set up a
connection for the COM port to which the cable is connected. The settings should
be: 9600 baud, 8-bit words, 1 stop-bit, no parity checking.
4. Hit the
SPACE
bar three times to open the Model 620x configuration main menu.
5. Enter a “
1
” to open the Station Configuration menu. Press “
1
” to toggle between
the station types.
6. Enter a “
2
” to enable the correct number of units (fire station resources, like trucks)
supported by this transponder. After selecting the number of units, press “e” to
return to the Station Configuration menu.
Summary of Contents for 025-9581M
Page 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Page 6: ...6 025 9581M ...
Page 40: ...Creating Console Positions 40 025 9581M ...
Page 45: ...45 Installing the VoIP Gateway Server ...
Page 78: ...Configuring Station Transponder Units 78 025 9581M ...
Page 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Page 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Page 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Page 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...