background image

 

 

 

 

HOUSEHOLD INSTANT GAS WATER HEATER 

 

(Flue Exhaust Type) 

 

INSTRUCTION MANUAL 

 

8l, 12l, 16l, 20l 

 

 

 

 

 

 

                    

 

 

 

 

 

Certified to ISO9001  

LPGSASA Permit No 1008-26/1-RSA-12-A

 

Indoor & Outdoor Use 

  

 

Please read the manual carefully and understand the operation prior to installation and use.  

 

The registered LPGSASA gas practitioner must commission the gas water heater before you sign the certificate of 

compliance. 

 

Retain this manual for future reference.  

Summary of Contents for JSD 24-LN1

Page 1: ...PGSASA Permit No 1008 26 1 RSA 12 A Indoor Outdoor Use Please read the manual carefully and understand the operation prior to installation and use The registered LPGSASA gas practitioner must commissi...

Page 2: ...y a SANS 1237 Approved 2 8kPa regulator must be fitted NB This appliance must be installed in accordance with SANS 10087 part 1 NB This appliance must ONLY be installed by a LPGSASA installer For Your...

Page 3: ...ance of the installation and be provided with a completion certificate You should only sign for acceptance of the installation when the installation is completed to your satisfaction Note that your in...

Page 4: ...cupboard neither should it be behind or above the gas water heater We DO NOT recommend using hose for the gas connection This will restrict the gas flow and volume and will underperform as a result W...

Page 5: ...reparation The gas water heater ignition function is powered by two large 1 5V DC Type D torch batteries Please insert the correct way as indicated on the battery housing Batteries are NOT included Ig...

Page 6: ...Installation of Flue...

Page 7: ...roperly sealed to prevent exhaust fumes entering to the inside The bend to the outside will not be less than 250mm from the centre of the flue to the gas water heater connection Precautions As a preca...

Page 8: ...the cold water inlet slightly Shut Off The gas water heater will shut off automatically when you close the warm water supply It will also shut off if you close the cold water supply to the gas water h...

Page 9: ...rd the Battery Power is too Low to Open the Solenoid Valve Change to New Quality Batteries Over Heat Protection Water Heater Automatically Shuts Off when Water Temperature is Above 77 C Restart Water...

Page 10: ...er heater and close the valve on the cylinder Remove the batteries from the gas water heater Contact your installer or your local qualified gas dealer Do NOT use the gas water heater for any other pur...

Page 11: ...ndings Gas Valve is Half Opened Open Gas Valve Completely Inadequate Supply of Gas Gas Feed Hose is too Long Check for Correct Hose Size and Length Diameter of Joints too Small Check for Restrictions...

Page 12: ...ressure This gas water heater operates on gas pressure 2 8 kPa ONLY Do not increase pressure If Installed Inside ensure that The installer abides by SANS 10087 1 specifications of cross ventilation NB...