D2O VCP Product Manual - 19
COMMAND SYNTAX
DETAILS
time -g
Displays the verbose system time in GMT
Time Parameters
COMMAND SYNTAX
DETAILS
gps -g
Displays the last acquired GPS position as Latitude and Longitude with GMT time acquired
gps -v
Displays if the GPS Fix is Valid
Global Positions System (GPS) Parameters
COMMAND SYNTAX
DETAILS
sys -c
Displays the Network Module Registration Code
sys -d
Displays the Receiver’s background noise level or RSSI (Received Signal Strength Indicator)
in dBm
sys -q
Displays the remaining storage space in the transmission queue in bytes
sys -L
Displays an estimate of the remaining power in the battery as a percentage (0% to 100%)
sys -P
<password> <password>
Sets a new administrator password. The new password parameter must be entered twice,
separated by a space. Passwords must not contain whitespace. This is an
Admin Restricted
command
sys SC
<1000 to 50000> <pw>
Resets the battery capacity after replacement. Requires battery pack capacity to be entered
as well as a special password provided by Zepiro. Please contact your dealer for assistance
D2O Unit System Parameters
The full list of available commands is shown below. The Commands are
shown in
Bold
text and available Parameters are shown in
Regular
text
within brackets
< >
. Detailed information about each command can be
found in the
7.3 COMMAND LIST
COMMAND SYNTAX
DETAILS
help
Displays a list of all available commands
help
<cmd>
Provides information about a particular command, where
<cmd>
is the command of
interest.
admin
<password>
Allows administrator access to modify the
Admin Restricted
editable parameters of the
device. All
Admin Restricted
parameters will be unavailable until this command is applied.
The default password is
password
apply
<A or D or F>
Accepts (
A
) or Discards (
D
) changes made to
Admin Restricted
settings of
acq
and
inp
commands when administrator access has been enabled. Parameter
F
restores all
modified parameters to their factory defaults.
report
Displays a Commissioning Report of all key parameters currently set on the D2O.
Admin Parameters