Use, Care, and Installation Guide

www.zephyronline.com

Model number: 
Serial Number: 

SEP15.0301 © 2015 Zephyr Ventilation LLC.

Siena

ZSI-E30AS

ZSI-E36AS

ZSI-E30AS-ES

ZSI-E36AS-ES

ZSI-E30AS-ES
ZSI-E36AS-ES

Summary of Contents for Siena ZSI-E36AS

Page 1: ...Use Care and Installation Guide www zephyronline com Model number Serial Number SEP15 0301 2015 Zephyr Ventilation LLC Siena ZSI E30AS ZSI E36AS ZSI E30AS ES ZSI E36AS ES ZSI E30AS ES ZSI E36AS ES...

Page 2: ...www zephyronline com...

Page 3: ...ting Options 7 Hood Specifications 8 Mounting the Range Hood 9 Ductless Recirculating 10 FEATURES CONTROLS ICON Touch Controls 11 12 MAINTENANCE Cleaning and Filter Care 13 Light Bulbs 14 TROUBLESHOOT...

Page 4: ...the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie s...

Page 5: ...C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified elec...

Page 6: ...ARDWARE PACKAGE CONTENTS MODELS ZSI E30AS ZSI E36AS ZSI E30AS ES ZSI E36AS ES PARTS SUPPLIED 1 Hood with internal blower 2 Baffle filters 1 Duct cover assembly top and bottom 1 Duct cover wall bracket...

Page 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Page 8: ...efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover...

Page 9: ...the outside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Som...

Page 10: ...Specifications Top of Hood Side of Hood Front of Hood AC In C L 10 1 2 29 15 16 35 7 8 12 3 8 STANDARD min ducted 27 1 2 min recirc 32 max 42 Z1C 00SI min ducted 46 1 2 min recirc 50 1 2 max 79 8 7 1...

Page 11: ...s 11 Position electrical outlet within the space covered by the telescopic duct covers and where it will not interfere with the round duct FIG B 12 Install duct work and duct tape 13 Power up hood and...

Page 12: ...ture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filter...

Page 13: ...ction is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan CFM to align with local codes and...

Page 14: ...icator disabled by default must be enabled if recirculating hood To enable Charcoal Filter Replacement Reminder With hood off hold button and button simultaneously for two seconds All LED indicators w...

Page 15: ...taining chlorine bleach Do not use orange cleaners Baffle Filters The baffle filters installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a...

Page 16: ...bs are not hot ZSI E30AS ES ZSI E36AS ES Access light bulb by removing light bulb lens cover by 1 screw FIG B Remove by turning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees st...

Page 17: ...osition 1 Adjust the filters until the whistling stops 2 The duct pipe connections are not sealed or connected properly 2 Check the duct pipe connections to be sure all connections are sealed properly...

Page 18: ...AS ES CIRCUIT DIAGRAM USE ONLY 13W GU24 FLUORESCENT LIGHT BULBS MODEL SPS T3 13GUS Power consumption shown for default 400 CFM blower configuration ACT 290 CFM Fan Max 82W 0 74A VOLTS HZ MAX AMPS 120...

Page 19: ...tension Kit Z1C 00SI To order parts visit us online at http store zephyronline com or call us at 1 888 880 8368 ZSI E30AS ZSI E36AS DESCRIPTION PART Replacement Parts Baffle Filter each 50200050 Halog...

Page 20: ...ter the first year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR...

Page 21: ...19...

Page 22: ...our new range hood at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps in more ways than one IT S IMPORTANT Ensures w...