 IMPORTANT SAFETY INSTRUCTIONS

 

FOR RESIDENTIAL USE ONLY

 

READ AND SAVE THESE INSTRUCTIONS

 PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

 

IMPORTANT

: Save these Instructions for the Local Electrical Inspectors use.

 

INSTALLER

: Please leave these Instructions with this unit for the owner.

 OWNER

: Please retain these instructions for future reference.

 Take care when using cleaning agents or detergents.
 Suitable for use in household cooking area

 WARNING

 - To reduce the risk of fi re or electric shock, do not use this fan 

with any Solid-State Speed Control Device.

 CAUTION

 - To reduce risk of fi re and to properly exhaust air, be sure to duct 

air outside – Do not vent exhaust air into spaces within walls or ceilings or into 
attics, crawl spaces, or garages.

 CAUTION

 - For general ventilating use only. Do not use to exhaust hazardous 

or explosive materials and vapors.

 

CAUTION

 - To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off  power unit.

 CAUTION

 - Please read specifi cation label on product for further information 

and requirements.

 WARNING

 – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 

PERSONS, OBSERVE THE FOLLOWING:

A. 

Use this unit only in the manner intended by the manufacturer. If you have 

ques        tions, contact the manufacturer.

B.

 Before servicing or cleaning unit, switch power off  at service panel and lock   

the service disconnecting means to prevent power from being switched on ac-
cidentally. When the service disconnecting means cannot be locked, securely    
fasten a prominent warning device, such as a tag, to the service panel.

 WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.

 Never leave surface units unattended at high settings. Boilovers cause smo-

king and greasy spillovers that may ignite. Heat oils slowly on low or medium 

S

a

fe

ty instruc

tions

- 4 - 

Summary of Contents for Range Hood APN-M90AWX

Page 1: ...www zephyronline com Plane APN M90ABX APN M90AWX RANGE HOOD Installation instructions...

Page 2: ...www zephyronline com HOTTE PER CUISINE Notice d utilisation Pag 21 CAMPANA EXTRACTORA Manual de utilizaci n Pag 41 CAPPA ASPIRANTE istruzioni per l uso Pag 61 2...

Page 3: ...LCULATION SHEETS pag 8 HOOD SPECIFICATION pag 9 INSTALLATION INTERNAL BLOWER pag 10 EXTERNAL IN LINE BLOWER PREPARATION pag 12 DUCTING OPTIONS pag 14 POWER SUPPLY CONNECTION pag 16 MOUNTING THE RANGE...

Page 4: ...to exhaust hazardous or explosive materials and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Plea...

Page 5: ...AREFUL TO PREVENT BURNS If the flames do not go out mmediately EVACUATE AND CALL THE FIRE DEPARTMENT B NEVER PICK UP A FLAMING PAN You may be burned C DO NOT USE WATER including wet dishcloths or towe...

Page 6: ...This unit must be grounded WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS A Do not check filters with hood working...

Page 7: ...1 1 M4 12 1 4 Duct Covers Control Electrical Junction Box Duct Cover Bracket Glass Light Bulbs Decorative Mesh Filters Range Hood Body List of Materials 7...

Page 8: ...www zephyronline com Ducting Calculation Sheet Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 8...

Page 9: ...Hood Specifi cations front of hood side of hood top of hood 9...

Page 10: ...by using a flat head screwdriver See Fig 1 2 Remove the 6 screws securing the blower plate to the blower housing and remove blower plate See Fig 2 3 Place the 6 metallic flange provided on the blower...

Page 11: ...and blower plate into blower housing by following the reverse instructions from step 2 See Fig 7 8 Connect 9 pin male molex connector from blower wire to 9 pin female molex connector on the capacitor...

Page 12: ...te to the blower housing and remove blower plate See Fig 1 2 Detach rectangular metal plate from blower plate See Fig 2A Flip blower plate 90 degrees and attach rectangular plate to blower plate side...

Page 13: ...nnection in accordance with the national electric code ANSI NFPA 70 1999 8 Secure cover to junction box using 2 screws Note1 A cable lock not included may be required by local codes Please review loca...

Page 14: ...spaces ceiling attics or garages All exhaust must be ducted to the outside unless using the recirculating op tion Use single wall rigid Metal ductwork only Fasten all connections with sheet metal scr...

Page 15: ...ce the paper template included with your hood on the wall to determine where to add the screws for mounting the hood Make sure the bottom of the template aligns with the bottom of where the hood will...

Page 16: ...t to the cover 5 Connect the wires of the hood to those of the power supply as described Fig 18 BLACK L line WHITE N neutral GREEN YELLOW G ground A double pole switch properly rated must be installed...

Page 17: ...over support bra cket so that it fits inside the top of the chimney and observing the distance shown in Fig 10 4 Secure duct cover bracket to top of wall just below the ceiling using 2 screws A provid...

Page 18: ...vent a fire hazard it is recommended to clean the filter a minimum of every 2 months or when instructed by the Metal Filter Clean indicator on the range hood controls Clean the range hood by carrying...

Page 19: ...PARTS Light Bulb GU4 20W each APN Z0B0030 OPTIONAL ACCESSORIES Recirculating Kit APN ZRC 00PN Replacement Charcoal Filters APN Z0F 00AC Duct Cover Extension APN Z1C 00PN To order parts visit us online...

Page 20: ...www zephyronline com 20...

Reviews: