background image

Use, Care, and Installation Guide

Model number: 

Serial Number: 

www.zephyronline.com

Roma Wall

ZRO-E30CS
ZRO-M90CS

APR14.0201 © Zephyr Corporation 

Summary of Contents for Roma Wall ZRO-E30CS

Page 1: ...Use Care and Installation Guide Model number Serial Number www zephyronline com Roma Wall ZRO E30CS ZRO M90CS APR14 0201 Zephyr Corporation...

Page 2: ...www zephyronline com...

Page 3: ...nce 6 Ducting Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Hood 9 Ductless Recirculating 10 FEATURES CONTROLS ICON Touch Controls 11 12 MAINTENANCE Hood and Filter Cleaning 13 Light Bulbs 14 TROUBLESHOO...

Page 4: ...are and utensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK...

Page 5: ...WULFDO LQVWDOOHU To assure that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code...

Page 6: ...ccessory Z1C 00RO Recirculating kit accessory ZRC 01RO HARDWARE PACKAGE CONTENTS 1 Light Bulb Removal Suction Cup PARTS SUPPLIED MODELS ZRO E30CS ZRO M90CS 1 Hood with internal blower 1 Duct cover wal...

Page 7: ...ent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round ro...

Page 8: ...ll ORRVH SHUIRUPDQFH DQG HI FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any d...

Page 9: ...de unless using the recirculating option Use single wall rigid metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Opt...

Page 10: ...w zephyronline com Installation RRG 6SHFL FDWLRQ 4 6 CL 29 15 16 35 7 16 14 1 8 3 15 16 22 1 16 STANDARD min ducted 27 min recirc 31 max 50 Z1C 00RO EXTENSION min ducted 42 min recirc 46 max 80 11 10...

Page 11: ...ith aluminum duct tape 10 Power up hood and check for leaks around duct tape 3ODFH WHOHVFRSLF GXFW FRYHUV RQWR KRRG DQG H WHQG LQQHU WRS GXFW FRYHU XSZDUGV DQG VHFXUH WR GXFW FRYHU EUDFNHW XVLQJ 0 VFU...

Page 12: ...LQJ DQG WKH RSWLRQDO FKDUFRDO OWHUV KHOS WR SXULI IXPHV H KDXVWHG IURP FRRNLQJ IRU UHFLUFXODWLRQ RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED LW LQFOXGHV FKDUFRDO OWHUV DQG DLU GLYHUWHU SODWH Hood...

Page 13: ...ction is enabled will turn the hood off and cancel the Delay Off Function ACT Verification Airflow Control Technology ACT allows the installer to set the maximum fan CFM to align with local codes and...

Page 14: ...bled if recirculating hood To enable Charcoal Filter Replacement Reminder With hood off hold button and button simultaneously for two seconds All LED indicators will illuminate for three seconds confi...

Page 15: ...cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters 7KH DOXPLQXP PHVK OWHUV LQVWDOOHG E WKH IDFWRU DUH LQWHQGHG WR OWHU RXW UHV...

Page 16: ...not hot 5HPRYH E WXUQLQJ EXOE FRXQWHU FORFNZLVH 1RWH XOE GRHV QRW XQVFUHZ LW WXUQV GHJUHHV stops and falls out I EXOEV DUH GLI FXOW WR WXUQ GXH WR SURORQJHG XVH UPO DWWDFK WKH LQFOXGHG JODVV VXFWLRQ F...

Page 17: ...r in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood The blower is working but the lights are not 1 Defective halogen bulb 1 C...

Page 18: ...ms VOLTS HZ MAX AMPS 120 60 5 USE ONLY TYPE MR16 GU10 50 W MAX HALOGEN LIGHT BULBS ZRO E30CS ZRO M90CS CIRCUIT DIAGRAM ACT 390 CFM Fan Max 320W 2 6A ACT 290 CFM Fan Max 303W 2 5A 3RZHU FRQVXPSWLRQ VKR...

Page 19: ...KH XVDJH RI 7 PD QRW EH necessary for your installation Please check your local codes for CFM restrictions By default the maximum blower CFM is set to 600 7R YHULI LI RXU LQVWDOOHU HQDEOHG 7 LWK KRRG...

Page 20: ...18 www zephyronline com Fan Curve Diagrams...

Page 21: ...HU HDFK Optional Accessories Recirculating Kit ZRC 01RO 5HSODFHPHQW KDUFRDO LOWHU HDFK Extension Duct Cover Z1C 00RO Universal Make Up Air Damper MUA006A To order parts visit us online at http store z...

Page 22: ...rst year from the date of your original purchase you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SH...

Page 23: ...Guide d utilisation d entretien et d installation www zephyronline com Num ro de mod le Num ro de s rie APR14 0201 2014 Zephyr Corporation Roma Wall ZRO E30CS ZRO M90CS...

Page 24: ...www zephyronline com...

Page 25: ...nstallation pour le conduit 7 6SpFL FDWLRQV GH OD KRWWH 8 Montage de la hotte 9 Reprise d air sans conduit 10 COMMANDES ICON Commandes lectroniques 11 12 ENTRETIEN 1HWWR DJH GHV OWUHV HW GH OD KRWWH 1...

Page 26: ...pas la hotte sans surveillance lorsque vous cuisinez h Utilisez toujours une batterie de cuisine et des ustensiles convenant au type et la quantit de nourriture que vous pr parez AVERTISSEMENT POUR R...

Page 27: ...QLTXHU DYHF XQ LQVWDOODWHXU pOHFWULFLHQ TXDOL p S assurer que l installation lectrique est ad quate et qu elle respecte le Code national de l lectricit la plus r cente dition du ANSI NFPA 70 ou des no...

Page 28: ...Liste du mat riel 4 www zephyronline com ZRO E30CS ZRO M90CS ZRC 01RO...

Page 29: ...pi x pi embout mural circ registre 30 pi x pi 7 or 10 circ coude 90 15 pi x pi 7 or 10 7 or 10 circ coude 45 9 pi x pi pi pi pi 6 chapeau de toiture circ 30 pi x pi 7 or 10 circ chapeau de toiture 30...

Page 30: ...senter des risques d incendie plus lev s tandis que les hottes LQVWDOOpHV WURS KDXWHV VHURQW GLI FLOHV j DWWHLQGUH HW YHUURQW OHXU HI FDFLWp HW OHXU UHQGHPHQW UpGXLWV Si elles sont disponibles consult...

Page 31: ...ements doivent tre dirig s l ext rieur de la maison moins que l option de reprise d air ne soit utilis e N utilisez que des conduits en m tal pour cloison simple Fixez toutes les pi ces du conduit ave...

Page 32: ...phyronline com Installation 6SpFL FDWLRQV GH OD KRWWH 4 6 CL 29 15 16 35 7 16 14 1 8 3 15 16 22 1 16 STANDARD min ducted 27 min recirc 31 max 50 Z1C 00RO EXTENSION min ducted 42 min recirc 46 max 80 1...

Page 33: ...es renforcements de bois pourraient derri re la cloison s che si aucune poutre n est pr sente Des GLVSRVLWLIV G DQFUDJH DX PXU SHXYHQW pJDOHPHQW rWUH XWLOLVpV PDLV YpUL H d abord les r glementations l...

Page 34: ...QQHOV DLGHQW j OD SXUL FDWLRQ des vapeurs et fum es de la cuisson lors de la reprise d air ENSEMBLE DE REPRISE D AIR REQUIS SI AUCUN CONDUIT N EST UTILIS HQVHPEOH FRPSUHQG GHV OWUHV j FKDUERQ HW XQ Gp...

Page 35: ...d utilisation pour teindre la hotte et annuler la fonction d arr t retardement V rification de la ACT La technologie de contr le du d bit d air permet l installeur d ajuster la quantit maximale d vacu...

Page 36: ...ar d faut doit tre activ lors de l utilisation du mode de recirculation d air Pour activer le rappel de remplacement des filtres charbon Lorsque la hotte est teinte tenez les touches et enfonc es simu...

Page 37: ...e et dans le sens du grain N utilisez pas de produits blanchir au chlore ou d agents nettoyants orange Filtres tamis en aluminium HV OWUHV j WDPLV HQ DOXPLQLXP LQVWDOOpV SDU OH IDEULFDQW RQW SRXU IRQF...

Page 38: ...es d vissant dans le sens contraire des aiguilles d une montre Note les ampoules ne se d vissent pas apr s une rotation de 60 degr s elles s arr tent et tombent de la douille RUVTX LO HVW GLI FLOH GH...

Page 39: ...use L appareil vibre H PRWHXU Q HVW SDV ELHQ p HQ SODFH 1 Fixez solidement le moteur en place 2 La roue du ventilateur est endommag e 2 Remplacez le ventilateur D KRWWH Q HVW SDV ELHQ pH HQ SODFH 9pUL...

Page 40: ...90CS SCHEMA DE CIRCUIT ROUGE ROUGE JUANE JUANE JUANE GRIS BRUN BRUN ROUGE BLEU BLEU VERT VERT BLANC BLANC BLANC BLANC NOIR NOIR NOIR NOIR BLANC Sch ma de c blage RQVRPPDWLRQ pQHUJpWLTXH DYHF OD FRQ JX...

Page 41: ...QDvWUH OHV UHVWULFWLRQV HQ PDWLqUH GH SLHGV FXEHV SDU PLQXWH Par d faut le nombre maximal de pi3 min du ventilateur est de 600 3RXU YpUL HU VL YRWUH LQVWDOODWHXU D DFWLYp OD 7 DSSX H VXU OD WRXFKH GH...

Page 42: ...18 www zephyronline com Diagrammes des courbes caract ristiques des ventilateurs...

Page 43: ...ssoires optionnels Ensemble de reprise d air ZRC 01RO Filtres charbon de remplacement chaque Z0F C002 Ensemble de prolongement de recouvrement de conduit Z1C 00RO Pour commander des pi ces visitez nou...

Page 44: ...responsable de tous les frais de main d uvre associ s la pr sente garantie Restrictions de la garantie NOTRE OBLIGATION DE R PARER OU DE REMPLACER NOTRE GR LE PRODUIT CONSTITUE VOTRE SEUL ET UNIQUE R...

Reviews: