             inBOX 24 / inBOX 20

 

http://www.zennio.com

 

              

Technical Support:

 

http://support.zennio.com

 

 

connection by means of the on-board screws. 

 

Inputs (4)

: input ports for the insertion of the stripped cables of external 

elements such as switches / motion detectors / temperature probes, etc. One 

of the two cables of each element needs to be connected to one of the slots 

labelled  “1” to “4”, while the other cable should be connected to the slot 

labelled as “C”. Note that all the external input devices share the “C” slot for 

one of the two cables. Please secure the connection by means of the on-

board screws. 

To get detailed information about the technical features of this device, as well as on the 

installation and security procedures, please refer to the corresponding 

Datasheet

bundled with the original package of the device and also available at 

www.zennio.com

.  

1.3

 

START-UP AND POWER LOSS 

During the start-up of the device, the Test/Prog. LED will blink in blue colour for a few 

seconds before the device  is ready. External orders will not be executed  during this 

time, but afterwards.  

Depending on the configuration, some  specific  actions  will also be performed during 

the start-up. For example, the integrator can set whether the output channels should 

switch to a particular state and whether the device should send certain objects to the 

bus after the power recovery. Please consult the next sections of this document for 

further details. 

On the other hand, when a bus power failure takes place, the device will interrupt any 

pending actions, and will save its state so it can be recovered once the power supply is 

restored. For safety reasons, the 

shutter channel

 will be stopped (i.e., the relays will 

open) if a power loss takes place, while the individual outputs will switch to the specific 

state configured in ETS (if any). 

Summary of Contents for ZIO-IB24

Page 1: ...inBOX 24 inBOX 20 Multifunction Actuator for Flush Mounting ZIO IB24 USER MANUAL ZIO IB20 Application program version 1 0 User manual edition 1 0 _a www zennio com...

Page 2: ...nstallation 4 1 3 Start Up and Power Loss 5 2 Configuration 6 2 1 General 6 2 2 Inputs Only inBOX 24 8 2 2 1 Binary Input 8 2 2 2 Temperature Probe 9 2 2 3 Motion Detector 9 2 3 Outputs 10 2 3 1 Manua...

Page 3: ...e 2 relay outputs configurable as 1 shutter channel with or without slats or Up to 2 individual ON OFF outputs 4 multi purpose inputs configurable as Temperature probes Binary inputs i e pushbuttons s...

Page 4: ...ly analogous for inBOX 20 although the inputs are not available The main elements of the device are described next Test Prog Pushbutton 3 a short press on this button sets the device into the programm...

Page 5: ...ce and also available at www zennio com 1 3 START UP AND POWER LOSS During the start up of the device the Test Prog LED will blink in blue colour for a few seconds before the device is ready External...

Page 6: ...ate deactivate all the required functionality Figure 2 Default screen Once activated Inputs only in inBOX 24 Outputs Logic Functions Thermostats only in inBOX 24 Master Light Scene Temporisation and M...

Page 7: ...It is possible to parameterise a certain delay to this sending 0 to 255 seconds Figure 3 Sending of Indication objects on bus voltage recovery Heartbeat Periodical Alive Notification this parameter l...

Page 8: ...IO DETEC X from Zennio Important older models of the Zennio motion detector e g ZN1IO DETEC and ZN1IO DETEC N will not work properly with inBOX 24 ETS PARAMETERISATION When Inputs has been activated i...

Page 9: ...r available in the inBOX 24 product section at the Zennio website www zennio com Notes The ZN1IO DETEC P motion detector is compatible with a variety of Zennio devices However depending on the device...

Page 10: ...re available per output Manual operation can be done in two different ways named as Test On Mode for testing purposes during the configuration of the device and Test Off Mode for a normal use anytime...

Page 11: ...he device will act over the output according to the length of the button press and to the current state A long press makes the shutter start moving upwards or downwards depending on the button being p...

Page 12: ...position of the shutter and the parameterised times Note after leaving the Test On mode the status objects will recover the values they had prior to entering Test On As the device is never aware of t...

Page 13: ...ecial action while switching to the Test On mode does require long pressing the Prog Test button Lock Manual Control unless the above parameter has been Disabled the Lock Manual Control parameter prov...

Page 14: ...ution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after execu...

Page 15: ...implements four Zennio thermostats which can be enabled and configured independently Please refer to the specific Zennio Thermostat user manual available in the inBOX 24 product section at the Zennio...

Page 16: ...to the KNX bus in both cases a shutter order a thermostat setpoint or mode switch order a constant value a scene Only the trigger object and the twelve status objects are required to be binary on off...

Page 17: ...takes off Scene if checked object ML General Switch off Scene will be enabled which will send a scene run save order configurable in Action and Scene Number whenever the general switch off takes off...

Page 18: ...tp support zennio com 18 when the courtesy switch on takes place in contrast to object ML General Switch Off Binary Object which sends the value 0 during the general switch off as explained above Figu...

Page 19: ...ing for that output or that channel such temporisation will be interrupted and only the delay and the action of the new scene will be executed ETS PARAMETERISATION Prior to setting the scene temporisa...

Page 20: ...e scene temporisation Therefore parameter Scene m Z Delay defines the delay that will be applied to the action defined in Z for the execution of scene m where Z may be a specific individual output shu...

Page 21: ...ta Entry x 1 byte Data Entry 0 255 53 68 2 Byte I C W DPT_Value_2_Ucount 0 65535 LF 2 bytes Data Entry x 2 bytes Data Entry DPT_Value_2_Count 32768 32767 DPT_Value_Temp 273 00 670760 00 69 76 4 Byte I...

Page 22: ...105 1 Bit I C W DPT_UpDown 0 1 CA Move 0 Raise 1 Lower 106 1 Bit I C W DPT_Step 0 1 CA Stop Step 0 Stop StepUp 1 Stop StepDown 1 Bit I C W DPT_Trigger 0 1 CA Stop 0 Stop 1 Stop 107 1 Bit I C W DPT_Ena...

Page 23: ...Door 0 1 Tx Window Status input 0 Closed 1 Open 132 162 192 222 1 Bit I C W DPT_Trigger 0 1 Tx Comfort Prolongation 0 Nothing 1 Timed Comfort 133 163 193 223 1 Byte O C T R DPT_HVACMode 1 Comfort 2 St...

Page 24: ...us Object 5 Binary Status 249 1 Bit I C W DPT_Switch 0 1 ML Status Object 6 Binary Status 250 1 Bit I C W DPT_Switch 0 1 ML Status Object 7 Binary Status 251 1 Bit I C W DPT_Switch 0 1 ML Status Objec...

Page 25: ...C T DPT_UpDown 0 1 Ix Short Press Move Up Down Shutter Switching 0 1 Up Down 1 Bit C T DPT_Step 0 1 Ix Short Press Stop Step Up Shutter Sending of 0 Stop Step Up 1 Bit C T DPT_Step 0 1 Ix Short Press...

Page 26: ...rt Press Dimming Status Input 0 100 284 290 296 302 1 Bit C T DPT_Switch 0 1 Ix Long Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 Ix Long Press 1 Sending of 1 1 Bit I C T W DPT_Switch 0 1 Ix Long Pre...

Page 27: ...1 Bit O C T R DPT_Alarm 0 1 Ix Open Circuit Error 0 No Error 1 Open Circuit Error 309 338 367 396 1 Bit O C T R DPT_Alarm 0 1 Ix Short Circuit Error 0 No Error 1 Short Circuit Error 310 339 368 397 1...

Page 28: ...dby Economy Building Protection 328 357 386 415 1 Bit O C T R DPT_Switch 0 1 Ix C2 Detection State Binary Binary Value 329 358 387 416 1 Bit I C W DPT_Switch 0 1 Ix C2 Enable Channel According to para...

Page 29: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: