background image

    

  

Z70 v2 

http://www.zennio.com

                                                                     Tecnical Support: 

http://support.zennio.com

 

 

85 

which of all the five extended modes will be included into the sequential  scrolling 

implemented by the buttons. 

 

Figure 79 

Climate Control - Extended Mode

 

  Depending on the mode selected by the user, the control object will be sent to the bus 

a certain value (see Table 7. 

HVAC Mode vs. Object Value

 

). The box will display the icon that corresponds to the new mode. Additionally, if the 

status object receives from the bus a value that represents any of the modes, the box 

will adopt the corresponding icon, while if an unrecognised value is received, no icon 

will be shown. 

Mode 

Value sent 

Auto 

0 (0x00) 

Heat 

1 (0x01) 

Cool 

3 (0x03) 

Fan 

9 (0x09) 

Dry 

14 (0x0E) 

Table 7. 

HVAC Mode vs. Object Value

 

 

Indicator Type

 [

Icon

 / Text

]: allows selecting whether the status indicator which each 

value

 

is represented will be text type or icon type.

 

As many drop-down lists of icons or 

text boxes will be displayed as modes have been enabled. 

2.2.2.1.4.3

 

Fan Control 

This  function  implements  a  2-button  (increase  /  decrease)  fan  control,  as  well  as  an  icon 

indicator.  

Summary of Contents for Z70 v2

Page 1: ...Z70 v2 KNX Full Color Capacitive Touch Panel with 7 display ZVIZ70V2 Application Program Version 3 0 User Manual Version 3 0 _b www zennio com USER MANUAL...

Page 2: ...1 Configuration 11 2 1 2 Locale 16 2 1 3 Backlight 20 2 1 4 Security 20 2 1 5 Internal Temperture Sensor 23 2 1 6 Ambient Luminosity Sensor 23 2 1 7 Touch Locking 23 2 1 8 Sounds 24 2 1 9 Update Sett...

Page 3: ...o Intercom Operation 98 Incoming Call 98 Ongoing Call 99 Previewing images from the camera 100 Call Log 101 ANNEX II Internal Call Operation 103 Outcoming Call 103 Incoming Call 105 Ongoing Call 106 C...

Page 4: ...zennio com 4 DOCUMENT UPDATES Version Changes Page s 3 0 _b Changes in the document Reference to the specific document Firmware Update is included 26 3 0 _a Changes in the application program Date ti...

Page 5: ...ed The most outstanding features of Z70 v2 are 7 inch backlit capacitive touch panel with 16 million colour LCD Display and screen resolution of 1280 x 800 pixels Multiple direct action functions full...

Page 6: ...hrenheit scales for the on screen temperature indicators being possible to select them in parameters or through communication object 4 customisable analogue digital inputs Heartbeat or periodic still...

Page 7: ...ton Controls o Switch o Two Object Short Press Long Press o Hold Release o Enumeration o Scene o Constant Counter Scaling Float o Room State 2 Button Controls o Switch o Switch Indicator Counter Scali...

Page 8: ...nical Support http support zennio com 8 1 Configuration Page optional which contains the time date settings the calibration of the built in temperature probe and the brightness and doorbell volume and...

Page 9: ...on program group addresses etc A short press on the Prog Test button 5 will make the device enter the programming mode The Prog Test LED 6 will then light in red On the contrary if this button is held...

Page 10: ...onditions of use described in EULA must be accepted by the end user before using the screen so during the installation must be postponed Once postponed the EULA dialog will be displayed again after tw...

Page 11: ...Parameters tab of the device 2 1 GENERAL This tab is divided into multiple screens all of which contain a set of global parameters regarding the general functionality of the device and therefore not...

Page 12: ...s place with a delay of up to 255 seconds to prevent bus overload The following sendings match the period set Default Theme After Download Light Dark allows choosing the device theme after download Sh...

Page 13: ...wing parameter is displayed Date and Time Update Request Delay disabled enabled allows selecting a delay 1 65535 s min h for the date and time request to the bus These requests will be made after upda...

Page 14: ...ation about the functionality and the configuration of the related parameters Note After programming or resetting the device 1 minute is required to carry out the sensors calibration To achieve a corr...

Page 15: ...iration Time 60 120 3600 sets the time that pairing code will be valid Advanced Configuration disabled enabled enables or disables the Advanced tab in the tree on the left see section 2 1 12 The proje...

Page 16: ...er sounds of device will be emitted C001 Switch Indicator object associated with Control 1 enabled by default Profile Display Brightness 1 byte percentage object to change the display brightness level...

Page 17: ...ocale en US The locale configuration can be selected through three types of communication objects A 1 byte object Enumerated to select the locale and the language from any of the configured in ETS A 2...

Page 18: ...ETS The expected values in this object are fixed from 0 to 4 When one of these values is received the texts of the file text_language region xlf corresponding to the regional configuration associated...

Page 19: ...es AR Locale 3 fr FR 1 byte object 1 Language text_es AR xlf Region Argentina 1 byte object 2 Language dflt xlf ETS texts Region Great Britain 1 byte object 4 Language dflt xlf ETS texts Region Great...

Page 20: ...to the specific manual Brightness available in the Z70 v2 product section at the Zennio website www zennio com for detailed information about the functionality and the configuration of the related pa...

Page 21: ...security is reactivated when the time for considering inactivity expires ETS PARAMETERISATION This screen permits selecting how many security levels one or two will be available for the configuration...

Page 22: ...new password typed afterwards will be anyway stored as the new password for level 1 Security Pad Labels parameter consisting in six additional textboxes intended for the customisation of the messages...

Page 23: ...ording to the current luminosity of the room Please refer to the specific manual Luminosity and Proximity Sensor available in the Z70 v2 product section at the Zennio homepage www zennio com for detai...

Page 24: ...e Number 0 Disabled 0 1 64 scene number that unlocks the touch Message Notification Touch Locked textbox to enter the desired message 2 1 8 SOUNDS Z70 v2 emits 3 types of sounds depending on the actio...

Page 25: ...abled enabled enables or disables acoustic signals when actions derived from button presses are executed If enabled the following parameter will be displayed Default Volume after Programming No Sound...

Page 26: ...DATE Z70 v2 incorporates two separate microcontrollers One of them is focused on interfacing with the KNX bus and on running the application program itself while the second one is dedicated to running...

Page 27: ...ible to re enable it unless the application program is reverted to the version that corresponds to the current firmware version In other words the device does not apply any further parameter changes i...

Page 28: ...ain language and it will be overwritten Other languages files will have to be generated externally and afterwards uploaded to the Z70 v2 For this purpose it will be possible to export and import langu...

Page 29: ...follow the nomenclature text_language region xlf Notes The finalization of the import and export of the translation files will be notified by a message on the Z70 v2 screen The USB memories must be fo...

Page 30: ...ntiated between those generated for the light theme folder light and those generated for the dark theme folder dark The structure of the folders must be as follows Figure 16 Custom icons light and dar...

Page 31: ...ndations to generate customised icons When designing and generating custom icons it is recommended to take into account the following indications to ensure their correct display in Z70 v2 The viewbox...

Page 32: ...nicate with other devices Note the characters included in this field must comply RFC 2396 standard IP Address 192 168 1 101 is used to uniquely identify the Z70 v2 for VoIP functionality This is the I...

Page 33: ...The same GetFace IP outdoor unit can call more than one Z70 v2 at the same time For that purpose the different Z70 v2 must be synchronized and connected to the same network The synchronization will al...

Page 34: ...rb Mode 1 bit object that enables and disables the do not disturb mode of the Z70 v2 VoIP functionality While this mode is active Z70 v2 will not receive any incoming calls but the calls will be recor...

Page 35: ...s responsible for controlling the doors locks Meanwhile each GetFace IP can call to a maximum of 10 Z70 v2 in parallel In addition in ANNEX I Video Intercom Operation the functions and controls of the...

Page 36: ...video intercom used can be of two types private or community The main difference between them is that community video intercom does not enable the camera image to be viewed if there is no incoming or...

Page 37: ...fferent networks IP Address 192 168 1 201 of GetFace IP must be set in addition to Specifying Gateway in IP Configuration tab see section 0 Opening Settings HTTP Command Secure Opening disabled enable...

Page 38: ...oor is possible Important For safety reasons it is recommended not to use this communication object or to use it under the responsibility of the integrator Door n disabled enabled enables or disables...

Page 39: ...eated Figure 22 Generic Outdoor Unit This tab is analogous to Outdoor unit n but the video intercom identification fields Outdoor unit ID and Set Static IP are excluded For more information on the con...

Page 40: ...0 v2 related to the internal calls functionalities ETS PARAMETERISATION After enabling Internal Calls in VoIP Calls tab section 2 1 11 a new tab will be incorporated into the tab tree Figure 23 Intern...

Page 41: ...r to the Webserver Tools manual available in the product section of Z70 v2 in Zennio web portal www zennio com 2 1 11 2 1Contact n ETS will enable to configure a list of up to 8 contacts for each Z70...

Page 42: ...risation of some advanced functions These functions are explained next ETS PARAMETERISATION After enabling the Advanced Configuration from Configuration screen see section Error No se encuentra el ori...

Page 43: ...time and then stops This function is intended to let the user clean the touch area with the certainty of not triggering unwanted actions A message is shown during the cleaning state When the timeout...

Page 44: ...e cleaning function The General Cleaning Function one bit object triggers the cleaning function when it receives a 1 from the KNX bus 2 1 12 2 POP UPS This function permits showing the user a pop up m...

Page 45: ...new tab will be incorporated into the tree on the left Figure 29 Pop ups tab Pop Up n disabled enabled allows to enable disable each pop up After enabling each pop up a new tab will be incorporated i...

Page 46: ...ects General Pop Up n Line x Line 1 4 Fixed Text Text Received from Object sets whether the corresponding text line will be pre defined or object dependent If Fixed Text is selected the following para...

Page 47: ...er a touch in the screen or when the proximity sensor detects presence Additional Condition No Additional Condition Do Not Send Unless All Additional Conditions are 0 Do Not Send Unless All Additional...

Page 48: ...8 Welcome Back Object Scene disabled enabled checkbox to enable the sending of a scene run request through General Scene send when the welcome back function is triggered and the condition if any evalu...

Page 49: ...f the integrator who may include up to twelve controls with different functionalities per page The remaining Configuration page is specific purpose as it is provided for user customisation of the devi...

Page 50: ...ne shown after the inactivity time elapsed Menu Page disabled enabled enables o disables a page with direct access to available general purpose pages Home Button in the Navigation Bar disabled enabled...

Page 51: ...ifferent controls or indicators Figure 35 Menu Page ETS PARAMETERISATION The Menu tab allows defining generic options regarding the enabled control pages which can be accessed from this screen Figure...

Page 52: ...ibuted Yes depending on the number of pages configured or be displayed as a static 3x4 grid No 2 2 1 2 CONFIGURATION PAGE The Configuration page lets the user to know or adjust certain technical value...

Page 53: ...d as the page title in the device Automatic Page Shaping No Yes allows choosing whether the boxes in the Configuration Page should be automatically distributed depending on the number of boxes configu...

Page 54: ...e Profile tab in the left menu For more information see section 2 2 1 2 2 Probe Calibration disabled enabled enables or disables the box to configure the offset of the internal temperature probe Alarm...

Page 55: ...n see section 2 2 1 2 3 Device Pairing enabled License required button to access to the pairing function which must be executed with each device desired to control the Z70 remotely For more details pl...

Page 56: ...Figure 41 Device ETS PARAMETERISATION After enabling the Device from Configuration Page screen see section 2 2 1 2 a new tab will be incorporated into the tree on the left Figure 42 Configuration Page...

Page 57: ...with no data loss Parameters Reset and Application Reboot the above two combined KNX disabled enabled indicator that shows the individual address of the device Program Version disabled enabled indica...

Page 58: ...ontrol the volume of pulsation and sending sound There are three volume levels in addition to the mute option Doorbell Volume disabled enabled box to control the volume of doorbell There are five volu...

Page 59: ...screen see section 2 2 1 2 a new tab will be incorporated into the tree on the left Figure 46 Configuration page VoIP calls Video Intercom Ringtone disabled enabled box to change the melody to be play...

Page 60: ...the mode will be activated when the call finishes Do Not Disturb Mode Timing disabled enabled this box set the time that the do not disturb mode will be active A time 0 will activate this mode indefin...

Page 61: ...ab in ETS left menu as shown in the Figure 49 Use this Text in the Device disabled enabled allows the text to be used as the page title in the device Icon Kitchen sets the icon that will represent the...

Page 62: ...No Yes sets whether the page is password protected at level 1 or without a password Two Levels No Level 1 Level 2 sets the level of security to access the page Objects to Show Hide Box disabled enabl...

Page 63: ...button will be displayed in the upper right of the box The control will be only executed when the button area is clicked Figure 51 Touch zone in box vs in button 2 2 2 1 CONTROL i This screen contain...

Page 64: ...indicator s and or button s of the box At the end of the list the custom icons Cx that must have been previously imported in Z70 v2 can be selected see section 2 1 9 4 Note a list with all icons avai...

Page 65: ...l be text type or icon type 2 2 2 1 1 2 Enumeration The box will behave analogously to the case of the Binary Indicator however it will be possible to distinguish up to 6 states When this function is...

Page 66: ...ollowing table Function Size Sign Range Related Object Integer 1 Byte Unsigned 0 255 Ci 1 Byte Unsigned Int Indicator Signed 128 127 Ci 1 Byte Signed Int Indicator 2 Bytes Unsigned 0 65535 Ci 2 Byte U...

Page 67: ...list of available ones will be mandatory This will be placed before or after the indicator according to the active locale see section 2 1 2 2 2 2 1 2 1 BUTTON CONTROL The box configured with this con...

Page 68: ...type or icon type 2 2 2 1 2 2 Two Objects Short Press Long Press The button in the box will react differently to a short press and to a long press setting a time threshold to distinguish both types of...

Page 69: ...consider it a long press 2 2 2 1 2 3 Hold Release This control function allows the user to configure sending a binary value on pressing and a different binary value on releasing the button In additio...

Page 70: ...ject Individual Box Scene Object specifies whether the scene value will be sent through the object General Scenes Send or through the individual object Ci Scene Send 2 2 2 1 2 5 Constant Numerical Con...

Page 71: ...ntrols Units permits specifying the measuring units of the displayed value For percentage indicators the symbol always will be displayed as unit 2 2 2 1 2 6 Room State Configuring with this function t...

Page 72: ...unication objects control object Ci Enumeration Control and the status Ci Enumeration Indicator will be 1 byte Up to six discrete states can be distinguished depending on the value that the status obj...

Page 73: ...user touches the buttons in the box a binary value will be sent through the Ci Switch object while the status object Ci Binary Indicator will determine the icon or text shown in the box The indicator...

Page 74: ...tor Type Counter Scaling Float Temperature sets the indicator type According to the selected indicator the objects The range of values allowed in each case and the name of the corresponding object are...

Page 75: ...changed from the box itself Figure 68 Temperature 2 Buttons Control Box Include Plus Sign before Positive Numbers disabled enabled shows the sign before positive temperature values 2 2 2 1 3 3 Two Obj...

Page 76: ...text type or icon type 2 2 2 1 3 4 Numerical Controls If any of the functions Counter Scaling or Float is assigned to the control user touches over the buttons will trigger the sending of a certain nu...

Page 77: ...ontrol Float 2 Byte 671088 64 670433 28 671088 64 670433 28 0 1 0 5 670433 28 0 1 1 670433 28 Ci 2 Byte Float Indicator Ci 2 Byte Float Control Table 6 Numerical Control 2 Button Units permits specify...

Page 78: ...case there will be two buttons in the box each of which can be configured independently Figure 72 2 Button Control Two Scenes Top Bottom Scene 1 64 value of the scene that will be sent to the bus afte...

Page 79: ...r Type set the desired behaviour for the buttons Standard a long press will make the device send to the KNX bus an order to start moving the shutter upwards or downwards with the top or bottom button...

Page 80: ...t Dimming from the dimmer with each long press on the top or bottom button respectively After a short press on the top button the value 1 will be sent through the Ci Light On Off binary object while a...

Page 81: ...om button the state will be switch between normal and Do Not Disturb Figure 75 2 Buttons Control Room State Show Pop Up When Activating Normal State No Pop Up 1 Pop Up 6 allows to select the pop up to...

Page 82: ...Ci Climate Real Temperature Indicator The box itself will permanently reflect the value in C o F of the status object whose value gets automatically updated after sending control orders that is after...

Page 83: ...wo temperatures at the same time The setpoint temperature will be displayed below the real temperature in a smaller font size and accompanied by a thermometer icon Figure 77 Setpoint Temperature with...

Page 84: ...the Heat mode while the other one will activate the Cool mode A centered indicator will reflect as an icon the currently active mode Figure 78 Climate Control Heat Cool Mode When the user activates t...

Page 85: ...the status object receives from the bus a value that represents any of the modes the box will adopt the corresponding icon while if an unrecognised value is received no icon will be shown Mode Value s...

Page 86: ...ed increase decrease are sent through the one bit object Ci Climate Fan Control 1 Bit Scaling scaling values are sent through the one byte object Ci Climate Fan Control scaling Enumeration integer val...

Page 87: ...equent parameter Value to Set the Auto Mode Send 0 Send 1 Figure 82 Fan Control Dedicated Object for Auto Mode However in this case the Auto mode can be activated in two ways and mutually exclusive By...

Page 88: ...pect or another depending on the currently active special mode Figure 83 Climate Control Special Mode When this function is assigned to the box two 1 byte objects Ci Climate Special Mode Control as th...

Page 89: ...represented will be text type or icon type If Text is selected as many text boxes will be displayed as modes have been enabled 2 2 2 1 5 OTHER 2 2 2 1 5 1 RGB Control This function is intended for se...

Page 90: ...rrent light level This indicator gets updated automatically as the user interacts with the box but is also conditioned by the values received from the bus through the already described objects Figure...

Page 91: ...the light level of the RGBW channels RGB and White Objects Separated DPT 232 600 and DPT 5 001 two objects will be enabled one 3 byte object analogous to RGB Pn Bi RGB Color and a 1 byte object for de...

Page 92: ...splay Pressing the Home button it will silence the sound notification and end the flashing but it will not confirm the alarm The alarm box icon will continue blinking Press the OK button in the alarm...

Page 93: ...that when received through Ci Alarm Trigger should be interpreted by Z70 v2 as an alarm situation Implicitly this parameter also defines the inverse no alarm value Periodic Monitoring No Yes activates...

Page 94: ...configured by default will be opened and it will be possible to navigate between the different parameterised video intercoms showing the image from the external unit s camera The call log will be com...

Page 95: ...er keypad in order to start a call top button and to the internal calls log bottom button Figure 93 Internal Call Box When the function is assigned to the box the following parameter come up Figure 94...

Page 96: ...n 2 1 11 2 is not enabled and the contact list is configured in ETS Numeric Keypad shows a keypad to enter the code number associated with the contact intended to call Figure 96 Numeric Keypad For mor...

Page 97: ...E Please refer to the specific user manual Temperature Probe available in the Z70 v2 product section at the Zennio website www zennio com 2 3 3 MOTION DETECTOR It is possible to connect motion detecto...

Page 98: ...Incoming call During an incoming call besides displaying the camera image the following functions will be available Accept Call opens the ongoing call dialog Figure 100 and notifies others synchronize...

Page 99: ...ssible see section 2 1 11 1 1 and 2 1 11 1 2 Exit the incoming call dialog is closed but no notification is sent to the bus so the call will continue on the rest of the synchronized screens Mute Call...

Page 100: ...5 5 When accessing the preview of the images the interface of Figure 101 will be shown Figure 101 Preview panel The interface will have the following elements Arrows will appear in case of having sev...

Page 101: ...ll Whether the call has been attended considering attended calls the accepted and the rejected calls and those where the door has been opened from the incoming call dialog or not attended Moreover if...

Page 102: ...hich the call was made First image captured at the start of the call Note if the video intercom does not have a camera or has not been possible to save the image the image area will be empty On the ri...

Page 103: ...is necessary as setting through the internal call box see section 2 2 2 1 5 6 Figure 104 Contact list The communication with the selected contact will be carried out after clicking on the accept call...

Page 104: ...nded Note Call will be cancelled if there is no answer within one minute When the contact has an ongoing call the outgoing call will be cancelled by displaying a message informing that the destination...

Page 105: ...eceiving a call from another screen the following dialogue will be showed Figure 109 Incoming call The following items are available during an incoming internal call Name assigned to the contact from...

Page 106: ...call dialog The other Z70 v2 shows the message informing that the call has ended Exit has the same effect as the reject call button Microphone Mute switches between mute and enable the Z70 v2 microph...

Page 107: ...ed calls not attended or outgoing Moreover if there is a not attended call since the last time the call log was accessed the indicative icon appears the internal call box and on the page where the box...

Page 108: ...through the Internet inside the Configuration tab see section Error No se encuentra el origen de la referencia Also before being able to control the device remotely it is necessary to make a previous...

Page 109: ...Z70 v2 to multiple remote applications PAIRING PROCEDURE Once Z70 v2 has been configured as described pressing on the Device Pairing box will bring up a pop up window similar to Figure 114 Figure 114...

Page 110: ...f the remote control application has been started or not about alarm events Alarm activation a box that has been assigned the Alarm function has either received the alarm trigger value from the KNX bu...

Page 111: ...SO 3166 1 Four Letters Code 8 2 Bytes I C W DPT_LanguageCodeAlpha2_ASCII General Translations Select Language Selection Through ISO 639 1 Two Letters Code 9 1 Bit I C W T U DPT_Enable 0 1 General Touc...

Page 112: ...ingtone 1 Play Ringtone 65 1 Bit I O C R W T DPT_Enable 0 1 VoIP Do Not Disturb Mode 0 Normal 1 Do Not Disturb 66 1 Bit C T DPT_Bool 0 1 VoIP Active Call 0 Call Finished 1 Active Call 67 68 69 70 1 Bi...

Page 113: ...342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391...

Page 114: ...Make Up Room 2 Do Not Disturb 1 Byte I C W T U DPT_Scaling 0 100 Cx Shutter Position 0 Top 100 Bottom 1 Byte I C W T U DPT_Scaling 0 100 Cx Light Dimming Indicator 0 Off 100 On 2 Bytes I C W T U DPT_...

Page 115: ...Control 128 127 1 Byte O C R T DPT_Value_1_Ucount 0 255 Cx 1 Byte Unsigned Int Control 0 255 2 Bytes O C R T DPT_Value_2_Count 32768 32767 Cx 2 Byte Signed Int Control 32768 32767 2 Bytes O C R T DPT...

Page 116: ...Cx Climate Fan Control Scaling 0 20 40 60 80 100 1 Byte O C R T DPT_Scaling 0 100 Cx Climate Fan Control Scaling Auto 100 1 Byte O C R T DPT_Scaling 0 100 Cx Climate Fan Control Scaling Auto 50 100 1...

Page 117: ...ACMode 1 Comfort 2 Standby 3 Economy 4 Building Protection Cx Climate Special Mode Control Auto Comfort Standby Economy and Building Protection 408 410 412 414 416 418 420 422 424 426 428 430 432 434...

Page 118: ...472 476 480 484 488 492 496 500 504 508 512 516 520 524 528 532 536 540 544 548 552 556 560 564 568 572 576 580 584 588 592 596 600 604 608 612 616 620 624 628 632 636 640 644 648 652 656 660 664 668...

Page 119: ...tter Move 0 Up 1 Down 4 Bit O C R T DPT_Control_Dimming 0x0 Stop 0x1 Dec by 100 0x7 Dec by 1 0x8 Stop 0xD Inc by 100 0xF Inc by 1 Cx Light Dimming 4 Bit Dimming Control 1 Bit I O C R W T U DPT_Switch...

Page 120: ...ity Percentage 0 100 993 999 1005 1011 1 Bit I C W DPT_Enable 0 1 Ix Input Lock 0 Unlock 1 Lock 994 1000 1006 1012 1 Bit C T DPT_Switch 0 1 Ix Short Press 0 Sending of 0 1 Bit C T DPT_Switch 0 1 Ix Sh...

Page 121: ...DPT_Scaling 0 100 Ix Short Press Constant Value Percentage 0 100 2 Bytes C T DPT_Value_2_Ucount 0 65535 Ix Short Press Constant Value Integer 0 65535 2 Bytes C T 9 xxx 671088 64 670433 28 Ix Short Pr...

Page 122: ...On 1 Bit C T DPT_Switch 0 1 Ix Long Press Light Off Sending of 0 Off 1 Bit I C W T DPT_Switch 0 1 Ix Long Press Light On Off Switching 0 1 1 Byte C T DPT_SceneControl 0 63 128 191 Ix Long Press Run S...

Page 123: ...on 1026 1055 1084 1113 1 Bit I C W DPT_Start 0 1 Ix Presence Slave Input 0 Nothing 1 Detection from slave device 1027 1056 1085 1114 2 Bytes I C W DPT_TimePeriodSec 0 65535 Ix Presence Waiting Time 0...

Page 124: ...k 0 1 Tx Special Mode Comfort 0 Nothing 1 Trigger 1 Bit I C W DPT_Switch 0 1 Tx Special Mode Comfort 0 Off 1 On 1160 1198 1 Bit I C W DPT_Ack 0 1 Tx Special Mode Standby 0 Nothing 1 Trigger 1 Bit I C...

Page 125: ...1225 1 Byte O C R T DPT_Scaling 0 100 Tx Sx Control Variable Cool PI Control Continuous 1182 1188 1220 1226 1 Byte O C R T DPT_Scaling 0 100 Tx Sx Control Variable Heat PI Control Continuous 1 Byte O...

Page 126: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: