Z70 v2
71
shows the permitted value range and the name of the object through which the values are sent
to the bus.
Function
Size
Sign
Range
Related Object
Integer
1 Byte
Unsigned
[
0
…255
]
[Ci] 1-Byte Unsigned Int Control
Signed
[
-128
…
0
…127
]
[Ci] 1-Byte Signed Int Control
2 Bytes
Unsigned
[
0
…65535
]
[Ci] 2-Byte Unsigned Int Control
Signed
[
-32768
…32767
]
[Ci] 2-Byte Signed Int Control
Scaling
1 Byte
[
0
…100
]
[Ci] Percentage Control
Float
2 Bytes
[
-671088.64
…
0
…670433.28
] [Ci] 2-Byte Float Indicator
Table 4.
Numerical constant controls
Units:
permits specifying the measuring units of the displayed value. For percentage
indicators, the symbol % always will be displayed as unit.
2.2.2.1.2.6
Room State
Configuring with this function the box, controlling the states of the room will be possible, as well
as show the associated pop-up. Thus, pressing the button in the box will cause the room status
to switch between
normal
and
Do Not Disturb
or
Make Up Room
.
Figure 63.
1-Button Control - Room State.
State
[
Make Up Room
/ Do Not Disturb
]: sets the status to be switched together with
Normal. The switched values are sent to the bus via the 1-byte object "
[Ci] Room State
".
Show Pop-Up When Activating Normal State
[
No
/ Pop-
Up 1 / … / Pop-Up 6
]: allows
to select the pop-up to be displayed when the normal mode is activated.