Z70 v2
15
Enable Web Configuration
[
disabled
/enabled
]: enables or disables access to
“webserver tools”, from which certain configuration and monitoring actions can be
performed on Z70 v2.
➢
Allow Password Reset
[
disabled
/enabled
]: enables the password for accessing
the Web server to be set to the factory default.
Please refer to the user manual “
Webserver Tools
” (available in the Z70 v2 product
section at the Zennio homepage,
) for detailed information about its
functionality and the configuration.
Note: In the event of a supply failure, the connection with the server will be lost, and
waiting for the screen to recover its generic IP to access it again will be necessary.
Remote Control through the Internet
[
disabled
/enabled
] (license required): enables or
disables remote control function (see ANNEX III. Remote Control via IP).
➢
Pairing Code Expiration Time
[
60 …
120
… 3600
]: sets the time that pairing code
will be valid.
Advanced Configuration
[
disabled
/enabled
]: enables or disables the “Advanced” tab in
the tree on the left (see section 2.1.12).
The project topology shows the following objects by default:
[General] Time of Day:
3-byte object for setting the internal time of the device, for
example, by linking it to a KNX clock. This object is also automatically sent after time
changes made by the user from the screen itself.
Note: although the DPT of this object considers a field for setting the day of the week,
Z70 v2 calculates it from the date and therefore ignores that field
.
Important: Z70 v2 does not have an RTC clock or battery to keep track of the time
in the absence of power. Therefore, it is important to receive the time periodically
from a device that obtains it through NTP and/or has a battery to prevent delays during
bus failures.
[General] Date:
3-byte object for setting the internal date of the device, for example, by
linking it to a KNX clock. This object is also automatically sent after date changes made
by the user from the screen itself.