Maximum Setpoint Value
: maximum setpoint value the user will be able to set.
Range: [-20, 95] x 1ºC. Default value: 30ºC.
Enablement
: sets the value to enable and disable the chrono-thermostat through
the object
[Pn][Bi] Daily Timer Enabling
. The options are “0=Disable;
1=Enable” (default option) “0=Enable; 1=Disable”.
When a box is configured as a chrono-thermostat, it looks as follows:
Figure 118
Chrono-thermostat (box)
The
switch button
on the left activates / deactivates the chrono-thermostat, that is,
resumes or stops the execution of the timed actions that may have been configured (the
configuration is not lost during the deactivation). While the chrono-thermostat is not
active, icon
is shown next to the switch button.
On the other hand, when the user touches on the
calendar icon
, a new window will pop
up to let the user set the actions to be executed:
Figure 119
Chrono-thermostat (pop up)
Each box configured as a chrono-thermostat contains
four pages
with
six
customisable timers
each, being possible for the user to configure up to 24 timed
actions.