FEATURES 

 

3 different configurable channels: shutter channels (up to 3) and individual 
outputs (up to 6) 

 

Outputs suitable for capacitive loads, maximum 140 µF. 

 

6 analog/digital inputs. 

 

Manual output operation with push button and LED Status indicator. 

 

10 logic functions. 

 

Output timing. 

 

Total data saving on KNX bus failure. 

 

Integrated KNX BCU. 

 

Dimensions 67 x 90 x 79 mm (4.5 DIN units). 

 

DIN rail mounting (EN 50022), with fixing clamp. 

 

Possibility of connecting different phases in adjacent outputs. 

 

Conformity with the CE directives (CE-mark on the right side). 

 

 

 

1. Analog/Digital inputs 

2. Upper outputs 

3. Output status LED indicator 

4. Output control button 

5. Programming/test 

LED  

6. Lower outputs 

7. KNX Connector 

8. Programming/test 

button 

9.  Fixing clamp 

9

 

Figure 1: MAXinBOX 66 v2 

Programming/Test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe 
mode. If this button is held for more than 3 seconds, the device enters the test mode. 
 
Programming/Test LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. The manual mode 
is indicated by the green color. During the start-up (reset or after KNX bus failure) and if the device is not in safe mode, it starts a blue blinking sequence. 

GENERAL SPECIFICATIONS 

CONCEPT 

DESCRIPTION 

Type of device 

Electric operation control device 

KNX supply 

Voltage (typical) 

29VDC SELV 

Voltage range 

21..31VDC 

Maximum 
consumption 

Voltage 

mA 

mW 

29VDC (typical) 

4.57 

132.53 

24VDC¹ 

10 

240 

Connection type 

Typical TP1 bus connector  for 0.80mm Ø rigid cable 

External power supply 

Not required 

Operation temperature 

0°C .. +55°C 

Storage temperature 

-20°C .. +55°C 

Operation humidity 

5 .. 95% (No condens.) 

Storage humidity 

5 .. 95% (No condens.) 

Complementary characteristics 

Class B 

Protection class 

II 

Operation type 

Continuous operation 

Device action type 

Type 1 

Electrical stress period 

Long 

Degree of protection 

IP20, clean environment 

Installation 

Independent device to be mounted inside electrical panels with DIN rail (EN 
50022) 

Minimum clearances 

Not required 

Response on KNX bus failure 

Data saving according to parameterization 

Response on KNX bus restart 

Data recovery according to parameterization 

Operation indicator 

The  programming LED indicates programming mode (red) and  test mode 
(green). Each output LED indicates its status 

Weight 

172g 

PCB CTI index 

175V 

Housing material 

PC FR V0 halogen free 

¹ Maximum consumption in the worst case scenario (KNX Fan-In model) 