Zennio Lumento X2 v2 Quick Start Manual Download Page 1

© Zennio Avance y Tecnología S.L. 

Edition 1 

Further information 

www.zennio.com

 

Page 1/2 

 

Lumento X2 v2 

2-channel constant voltage PWM dimmer for DC LED loads 

ZDILX2V2 

TECHNICAL DOCUMENTATION 

 

FEATURES 

 

2  constant  voltage  configurable  channels  (combinable 
independent channels and TW channel) 

 

1  relay  to  control  the  LEDs  power  supply or  for  independent 
use 

 

Supports KNX Data Secure 

 

Master Light control 

 

External 12-40 VDC power supply 

 

Manual  output  operation  with  push  button  and  LED  status 
indicator 

 

Total data saving on KNX bus failure 

 

Integrated KNX BCU (TP1-256) 

 

Dimensions 137.4 x 55 x 30.5 mm 

 

Surface-mounted  inside  panels,  distribution  boxes  or  false 
ceiling 

 

Conformity with the CE, UKCA, RCM directives (marks on the 
right side) 

 
 

 

 

5  6 

Figure 1: Lumento X2 v2 

GENERAL SPECIFICATIONS 

CONCEPT 

DESCRIPTION 

Type of device 

Electric operation control device 

KNX supply 

Voltage (typical) 

29 VDC SELV 

Voltage range 

21-31 VDC 

Maximum 
consumption 

Voltage 

mA 

mW 

29 VDC (typical) 

4.9 

142.1 

24 VDC¹ 

10 

240 

Connection type 

Typical TP1 bus connector for 0.8 mm Ø rigid cable 

External power supply 

12-40 VDC 

Operation temperature 

0 .. +55 °C 

Storage temperature 

-20 .. +55 °C 

Operation humidity 

5 .. 95% 

Storage humidity 

5 .. 95% 

Complementary characteristics 

Class B 

Protection class / Overvoltage category 

II / III (4000 V) 

Operation type 

Continuous operation 

Device action type 

Type 1 

Electrical stress period 

Long 

Degree of protection 

IP20, clean environment 

Installation 

Independent  device  to  be  surface-mounted  inside  electrical  panels  or 
boxes. The installation is also possible in false ceiling. 

Minimum clearances 

Not required 

Response on KNX bus failure 

Data saving according to parameterization 

Response on KNX bus restart 

Data recovery according to parameterization 

Operation indicator 

The programming LED indicates programming mode (red) and test mode 
(green). The error LED notifies the existence of an error. 

Weight 

134 g 

PCB CTI index 

175 V 

Housing material 

PC FR V0 halogen free 

¹ Maximum consumption in the worst-case scenario (KNX Fan-In model). 

1. Power Supply Relay 

2. KNX connector 

3. External power supply 

4. Output channels 

5. Programming LED 

6. Programming button 

7. Test button 

8. Power supply LED 

9. Error notification LED 

 

PROGRAMMING BUTTON: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe 
mode. In  order  to  perform  a  KNX  Secure factory reset, while  the device is in safe mode, press the  button for  10  seconds until the  programming  LED 
changes its state.  
TEST BUTTON: short press changes sequently each channel to 100%. A long press regulates the active channel. 
PROGRAMMING LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. During the start-up 
(reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash. The Test-On mode is indicated through green color. 

 