background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Linecoupler CL 

 

 

KNX-TP Line Coupler & Repeater 

   

 

 

 

 

 

ZSYLCCL  

 

 

 

 

 

 

U

S

E

R

 M

A

N

U

A

L

 

 

 

 

 

 

 

 

Application Program version: [1.0]  

User Manual version: [1.0]_a 

 

 

 

www.zennio.com 

 

 

 

Summary of Contents for Linecoupler CL

Page 1: ...Linecoupler CL KNX TP Line Coupler Repeater ZSYLCCL USER MANUAL Application Program version 1 0 User Manual version 1 0 _a www zennio com...

Page 2: ...1 Linecoupler CL as a Line Coupler 6 2 1 2 Linecoupler CL as a Repeater 10 2 2 Manual Function Button 11 2 2 1 Manual Operation Mode 11 2 2 2 Hard Reset to Factory Defaults 12 3 ETS Parameterisation...

Page 3: ...e to a KNX mainline or a KNX mainline to a KNX backbone line line coupler mode or to simply link together two line segments line repeater mode Figure 1 Context Topology These are the most outstanding...

Page 4: ...ful at runtime and for set up and troubleshooting purposes 6 Lighting Indicators LEDs for accurately showing the bus status of each line making the detection of abnormal situations excessive bus load...

Page 5: ...shown in Figure 2 may be pressed to set Linecoupler CL in programming mode After a short press the programming LED will light in red The behaviour of the additional LEDs and the manual function butto...

Page 6: ...evice may perform line coupling in the nodes marked as LC where a line connects to a mainline or a mainline connects to a backbone line In both cases Linecoupler CL offers an insulated coupling interf...

Page 7: ...und or drop block it if it is not Note making further changes to a project addresses etc requires downloading the updated filter table to the line coupler Example if the line coupler has been paramete...

Page 8: ...nline and for the line Example in the example shown in Figure 3 if the line coupler with address 3 2 0 reads a telegram on the mainline destined to the device with physical address 3 1 2 it will compa...

Page 9: ...tus in the primary bus BLINKING green traffic OFF no traffic BLINKING red errors in the transmissions Line Traffic LED shows the traffic status in the secondary bus BLINKING green traffic OFF no traff...

Page 10: ...Figure 6 both containing devices need to be linked for extending the line Linecoupler CL offers such linking interface with proper electrical insulation for the connections Figure 6 Forbidden Situati...

Page 11: ...ns of the line repeater application program 2 2 MANUAL FUNCTION BUTTON Linecoupler CL features an additional pushbutton on the top cover next to the status LEDs see 4 in Figure 2 which permits Activat...

Page 12: ...button permits performing a hard reset of the device which will set it back to the factory default state including the initial individual address These are the steps Press the manual function button...

Page 13: ...e device should be added to the project where desired And then the configuration process begins by entering the Parameters tab of the device The following sections provide a detailed explanation about...

Page 14: ...sses in other words all telegrams destined to physical addresses will be transmitted while in manual mode on the other hand group telegram filtering will stay the same as in normal mode Transmit Group...

Page 15: ...k enables the group address filtering and drops all telegrams destined to physical addresses Group Addr Physical Addr Filter enables both the group address and the physical address filtering Group Add...

Page 16: ...ed permanently Physical Addresses Repetition if Errors on Main Line sets the desired reaction upon transmission errors in the mainline e g busy receiver acknowledgement not received negative acknowled...

Page 17: ...tion errors on the destination line negative ACKs sent by the devices will overwrite this ACK so having this parameter enabled will cause no damage or information loss 3 4 LINE This screen permits par...

Page 18: ...evice should be added to the project where desired And then the configuration process begins by entering the Parameters tab of the device In the following sections a detailed explanation can be found...

Page 19: ...e in manual mode Transmit Group Addr Telegrams the device will not filter group addresses note that this has no practical effect the line repeater does always let group telegrams pass in normal mode w...

Page 20: ...The following parameters will be locked unless Custom has been selected Physical Addresses Telegrams sets the behaviour of the device regarding telegrams destined to individual addresses The available...

Page 21: ...ry telegram it receives even if not routed to the line on the other side Send Confirmation on Own Telegrams Yes No permits enabling or disabling self acknowledgment This extra feature offers the possi...

Page 22: ...m Technical Support http support zennio com 22 Figure 14 Line Linerepeater CL Please refer to section 4 3 for a detailed description of these parameters taking into account that section 4 3 applies to...

Page 23: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...

Reviews: