The KLIC-DA LT  application program provided by Zennio  focuses on controlling 

Altherma LT

 (from 

Low Temperature

) systems, in contrast to the 

Altherma HT

 (from 

High Temperature

) systems. 

An Altherma LT system consists of a series of elements (an external unit, a hydrobox, 
an internal unit, the user interfaces, etc.), and the specific “P1/P2” communication bus, 
which allows the user interfaces (typically, one acting as the 

main

 control and the other 

as an 

additional

 control) communicate to each other and to the Altherma system. 

Note

only the main interface interacts with the Altherma LT system. Any order from / to 

the additional interface will reach the main interface too

KLIC-DA is meant to 

replace the aforementioned additional

  interface, and  thus  to 

communicate only to the main interface and not to the Altherma LT system directly.  

The main functions performed by the KLIC-DA LT application program are: 

  Management of the 

domestic hot-water

 (DHW) system. 

  Management of the 

room

 

climate

 system (Leaving Water Method). 

 

Error handling

  Simultaneous  monitoring  of 

multiple  indicators 

(temperature  setpoints, 

actuator states, sensors…) reported by the Altherma system. 

On the other hand, Altherma LT systems feature three climate control methods: 

  Control of the

 leaving water temperature

 (LWT), 

  Control through a 

user interface

 configured as a thermostat, 

  Control though an 

external thermostat

 (TH). 

The KLIC-DA LT  application program is only compatible with Altherma LT systems 
configured for an 

LWT control

, and with 

only one climate zone

 (Altherma LT systems 

permit up to two climate zones with independent setpoint temperatures). 

 

 

Summary of Contents for KLIC-DA LT

Page 1: ...KLIC DA LT KNX DAIKIN Altherma LT Gateway ZN1CL KLIC DA U SER MANUAL Application Program Version 1 0 User Manual Version 1 0 _a www zennio com...

Page 2: ...Management DHW 7 2 2 Climate control management 7 2 3 Error Handling 7 2 4 Additional Indicators 8 2 5 Start up 8 3 ETS Parameterisation 10 3 1 Default Configuration 10 3 1 1 Configuration 11 3 1 1 1...

Page 3: ...m the specific Altherma user interfaces Moreover any status updates and feedback received from the Altherma system will also be forwarded by KLIC DA towards other KNX devices Figure 1 KLIC DA Daikin A...

Page 4: ...erface too KLIC DA is meant to replace the aforementioned additional interface and thus to communicate only to the main interface and not to the Altherma LT system directly The main functions performe...

Page 5: ...ning elements is as follows Programming Button 3 a short press on this button will set the device into the programming mode making the red component of the LED 2 indicator light up If the button is he...

Page 6: ...em disconnected the effective colour will be orange still as the red and green components will be lighting still Input Terminal for the Two Wire Communication Cable 4 slot for the connection of the tw...

Page 7: ...unction The ON OFF state of the Buster mode The setpoint temperature of the DHW tank It can also report whether the DHW tank is currently under operation or not 2 2 CLIMATE CONTROL MANAGEMENT In relat...

Page 8: ...ay initialise at a different moment than the main control so it is advisable to restart the Altherma system after installing KLIC DA and downloading the application Notwithstanding the above in order...

Page 9: ...after the initial sequence according to them The above sequence occurs whenever KLIC DA powers up or detects communication errors with the P1 P2 bus It also takes place when the Altherma system itself...

Page 10: ...to start the configuration In the following sections a detailed explanation is provided about how to parameterise the different functionalities of the device in ETS 3 1 DEFAULT CONFIGURATION This sec...

Page 11: ...ables or disables the room climate function See section 3 1 1 2 Error Handling which enables or disables the error monitoring function See section 3 1 1 3 Advanced While all of the above will still re...

Page 12: ...update other KNX devices when the device starts up after a bus power failure or a download from ETS DHW On Off Status DHW Booster mode On Off Status DHW Temperature Status DHW Operating Status Climate...

Page 13: ...maximum temperature set in the main user interface KLIC DA LT will truncate it and send the Altherma LT system the maximum permitted setpoint On the other hand in case the value is under the minimum p...

Page 14: ...imate system Climate Temperature two byte object that sets the desired setpoint temperature for the climate system In case the value received through this object exceeds the allowed setpoint range the...

Page 15: ...munication error and will then require that the Altherma LT system is switched off prior to removing the unneeded additional control Once removed the Altherma LT system can be switched back on KLIC DA...

Page 16: ...ver the Altherma LT system notifies a temperature change KLIC DA LT will automatically send the corresponding object to the KNX bus 3 1 1 5 ACTUATORS STATUS No additional parameter configuration is re...

Page 17: ...d by the Altherma LT system Addit Info Energy Production four byte object that reflects the total energy production in kWh till now as reported by the Altherma LT system Addit Info Flow Rate two byte...

Page 18: ...to the bus write or read requests after a bus failure the marks W or R will be shown respectively for transmissions or read requests No Size I O Flags Data Type DPT Functional Range 1st boot P Reboot...

Page 19: ...60 0 W W Temperatures Refrigerant Current Refrigerant Temperature 22 1 Bit O C T R DPT_Switch 0 1 W W Actuators Pump Status of Pump On Off 23 1 Bit O C T R DPT_Switch 0 1 W W Actuators Compressor Stat...

Page 20: ...your inquiries about Zennio devices http zennioenglish zendesk com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 Fax 34 925 337 310 www zennio com...

Reviews: