Besides the type of the shutters, the user must configure their specific functions, common to both 

types of shutters: 

 

Times: 

to  define  the  different  times  (in  tenths  of  seconds)  associated  to  the  shutter 

movement, such as: 

 

Main  time  (Shutter  length): 

this  is  the  time  the  shutter  needs  to  cover  its  length 

completely. Both times (rising time or lowering time) can be used in this field, but if there 

was  some  difference  between  these  two  times,  Lowering  time  will  be  considered  as 

“master” and should be used to fill in this field. Rising time in this case will be set in the 

“Total Time Up” field, enabled for this purpose (when selecting “Yes” in the field “Are total 

Time Up and Down different?”).

 

This  variable  will  not  need  to  be  periodically  calibrated,  since  the  exact  shutter  position 

remains on ACTinBOX MAX6 (even when the power failure occurs). 

 

Security time (pause to change the movement direction): 

this time is applied by 

the actuator to protect the drive when the movement direction of the shutter is changed. If 

the device  receives the  order  to  lower  the  shutter  while  this  is being  raised, ACTinBOX 

MAX6 will stop it for a while (security time) to later lower it. It is recommended to keep the 

default value in this field: 5 tenths of second. 

 

Are  total  time  Up  and  Down  different?: 

whenever  the  shutter  rising and  lowering 

times are different (e.g. heavy shutters) this field should be dropped down to set the rising 

shutter time, as mentioned before. The lowering time must be set in the “Main time” field. 

 

Additional  time  when  the  shutter  gets  the  limit:

  this  parameter  guarantees  the 

shutter always gets its lowest or highest level, level by setting an extra time for the drive 

to  keep  moving  once  the  shutter  took  up  its  rising/lowering  times,  preventing  small 

maladjustments.  This  parameter  appears  disabled  by  default,  but  it  is  recommended  to 

set a value on it, to ensure the proper movement of the shutter. 

If  the  shutter  is  the  type  Blind  with  slats  (see  figure  3.12),  some  other  times  and  specific 

parameters appear. All of them are explained in detail in the Annex I of this manual.  

Note:  After  programming  the  device  with  ETS,  ACTinBOX  MAX6  considers  the  shutter  is 

completely raised, so any raising order will be ignored. 

Below an example of a possible shutter configuration. 

Summary of Contents for ACTinBOX MAX6

Page 1: ...ACTinBOX MAX6 6 Outputs Actuator ZN1IO AB60 Program version 3 0 Manual edition a PRODUCT MANUAL...

Page 2: ...nfiguration 5 2 1 Individual outputs 5 2 2 Shutter channels 6 2 3 Relay control using IR remote 7 3 ETS Parameterization 9 3 1 Default configuration 9 3 2 Outputs 10 3 2 1 Individual outputs 11 3 2 2...

Page 3: ...s with or without slats Up to 6 individual outputs 10 multi operational logical functions module which may be enabled or disabled independently by means of a communication object Manually operating ov...

Page 4: ...ramming mode and the associated LED 3 lights red Note If this button is held while plugging the device into de KNX bus ACTinBOX MAX6 goes into secure mode The LED blinks red every 0 5 seconds Outputs...

Page 5: ...ers This section is meant to control the outputs by means of a timer setting times for the ON and OFF of the output Scenes Allows running and or saving a specific action over the output s where this f...

Page 6: ...of the shutters in charge of carrying out these actions should be properly connected to each output of the channel to perform the required action The Table 1 1 shows the action carried out by the out...

Page 7: ...pecific position via 1 bit communication object Start up configuration Default or custom All these configuration options are explained in detail in the section 3 ETS Parameterization 2 3 RELAY CONTROL...

Page 8: ...re 2 1 Pressing zones in the IR remote The relay control using IR remote is just an output test of the actuator None of its parameterized functions such as scenes timers etc are taken into account at...

Page 9: ...figuration from which the device parameterization starts When entering for the first time to the parameters edition of ACTinBOX MAX6 the following window will be shown Figure 3 1 Configuration screen...

Page 10: ...ear in the menu on the left side It looks as follows Figure 3 2 Outputs configuration The outputs are grouped in pairs by channels up to 3 named from A to C disabled by default When selecting one of t...

Page 11: ...tus of the output activated or deactivated OX Block allows blocking unblocking the output disable enable its control by sending the values 1 or 0 to the object respectively Note Only the Alarm functio...

Page 12: ...nt through the object OX Timer and the OFF response in the output takes place If no delay is needed please set 0 in this field On Duration time the output remains ON before recovering the OFF status A...

Page 13: ...ponding object before the parameterized time for the timer ends Flashing See figure 3 6 This function is meant for the output to run the sequence ON OFF ON OFF when needed It can be parameterized an O...

Page 14: ...ne is received through the Scenes object the parameterized action for the output will be carried out OFF or ON so it will be possible to create different environments in the installation Besides runni...

Page 15: ...t wanted it will be necessary to receive the opposite value to Trigger through the Alarm object before the cyclical monitoring period ends The cyclical monitoring can be disabled by setting a 0 in thi...

Page 16: ...active alarm Normal depending on what was parameterized on Trigger Value the alarm will be deactivated when the actuator receives a 0 or a 1 through the alarm object Frozen with this method a normal d...

Page 17: ...tion is chosen ETS will show the following window Figure 3 10 Custom Start up configuration Where to configure the following parameters Initial position this field defines the exact initial position f...

Page 18: ...a simple raise lower movement When selecting this kind of shutter 2 communication objects will be enabled CX Move and CX Stop to raise lower and stop the shutter movement respectively Moreover the fo...

Page 19: ...In the next figures it can be seen the windows that appear when configuring an output channel as Shutter no slats and as Blind with slats Figure 3 11 Channel A configured as Shutter no slats Figure 3...

Page 20: ...device receives the order to lower the shutter while this is being raised ACTinBOX MAX6 will stop it for a while security time to later lower it It is recommended to keep the default value in this fie...

Page 21: ...when it is completely down 100 The rest of values represent the intermediate values It can be chosen by parameter whether the shutter position is sent every second or not enabling or not the parameter...

Page 22: ...account that the associated numerical values to learn scenes are in the range 128 191 the values 0 63 are reserved for running scenes Up to 5 scenes can be run and or learnt for each shutter channel...

Page 23: ...ir current position Please see the following example of scenes configuration Example Consider a facility where 3 scenes will be used 4 6 and 18 in ACTinBOX MAX6 to locate the blind with slats in a pre...

Page 24: ...nel is in Alarm 1 status and Alarm 2 occurs Alarm 1 prevails Trigger value set the value 1 or 0 to activate the alarm status An alarm status will be activated when the value set in this field is sent...

Page 25: ...rm is not deactivated any action over the channel outputs will be ignored After a while t2 the alarm is deactivated CX Alarm 0 thus lowering the shutter Before the cyclical monitoring period 3 minutes...

Page 26: ...n this case it will be necessary that the output is manually enabled from another point in the installation End this parameter sets the channel response in one of these statuses when the alarm finishe...

Page 27: ...slats it will also apperar the parameter Select Slats position where to established the position to move the slats to when receiving the value 1 through the corresponding positioning object If two dir...

Page 28: ...ll show the following window Figure 3 17 Custom Start up configuration Where to configure the following parameters Initial position this field defines the exact initial position for the shutter should...

Page 29: ...erent logical functions can be enabled independent of each other which can carry out up to 4 operations each To use any of them it is necessary to enable them in the following ETS window which appears...

Page 30: ...percentage when it is completely open The shutter is in the position down position 100 in percentage when it is completely closed And the slats positioning criteria The slats are in the position up or...

Page 31: ...ain in detail every available option Figure 4 2 Blinds with slats configuration window ETS As seen in figure 4 2 for this type of shutters several times can be parameterized On the one hand the times...

Page 32: ...tion after the blind reaches the desired position or not Example Suppose the parameter Maintain slats positioning when shutter completes motion has been enabled The initial position of the slats is 50...

Page 33: ...d slats can be configured independently Alarms Response Specific position Same as before Direct positioning Configuration of the positions 1 or 2 depending on the parameterized number in percentage of...

Page 34: ...1 0 Last LF 1 bit Data Entry 1 LF 1 bit Data Entry 32 Binary Data Entry 0 1 Binary Data Entry 0 1 34 49 1 byte I W 0 255 0 Last LF 1 byte Data Entry 1 LF 1 byte Data Entry 16 1 byte data entry 0 255 1...

Page 35: ...bytes INDIVIDUAL OUTPUTS 96 101 1 bit I W 0 1 Indifferent Indifferent OX ON OFF N O 0 Open 1 Close relay N C 0 Close 1 Open relay 102 107 1 bit O RT 0 1 Parameteriz Parameteriz OX Status 0 Output Off...

Page 36: ...rsed moving 0 Down 1 Up 120 125 even 1 bit I W 0 1 Indifferent Indifferent CX Direct positioning 1 Go to position 0 No action 120 125 odd 1 bit I W 0 1 Indifferent Indifferent CX Direct positioning 2...

Page 37: ...G A vwww zennio com 37 SECTION NUMBER SIZE IN OUT FLAGS VALUES NAME DESCRIPTION RANGE 1st TIME RESET RESET 153 1 bit O T 0 0 0 Reset 0 Voltage recovery Sending of 0 154 1 bit O T 1 1 1 Reset 1 Voltage...

Page 38: ...38 ZENNIO TECHNICAL DOCUMENTATION BECOME USER http zennioenglish zendesk com TECHNICAL SUPPORT...

Reviews: