Flowire Converter Configuration Manual

A100K11422

3  Connections & Indications

3.1  Flowire Connection

The Flowire Converter must be connected to the Flowire star configuration 

using twisted cabling as shown. The red wire is the positive supply voltage 

while the black wire is the negative supply voltage. The power supply 

voltage used depends on the type of devices in the star configuration.

 

48 VDC PSU

 : When using Flowire with Vingtor-Stentofon IP intercoms 

and access panels.

 

24 VDC PSU 

: When using Flowire with Vingtor-Stentofon Ex intercoms 

and access panels. (FCDC2 is particularly suited to this.)

For the sake of convenience, the Flowire Converter is equipped with two 

connections to the star configuration.

 

L

Please note that these two connections are equivalent. 

3.2 

Ethernet Connection

Ethernet is connected via the RJ45 port. This supplies 10/100 Mbps 

Ethernet (in and out) and power out over spare pairs (

FCDC1 only

). The 

power on the spare pairs is the same voltage as the one supplied to the 

converter. Hence, at least 40 volts must be applied to the converter in order 

to ensure stable operation when powering IP intercom stations directly 

through their Ethernet ports. If the station has a 24V input, the current can 

be reduced to 24 volts by separating the spare pairs from the CAT cable 

and connecting it to this input.

 

L

DO NOT power the Flowire Converter through the RJ45 port. Trying 

to do so with a PoE injector will damage the converter.

 

L

DO NOT use Gigabit switch with FCDC1 as this will damage the 

switch

 

L

The RJ45 port on FCDC1 is NOT a PoE-compatible output but 

DC voltage on spare pairs which is present at all times. It MUST 

NOT be connected to any equipment that can be damaged by this 

voltage.

3.3 

Indicator LEDs

The Flowire Converter is equipped with three green LEDs. These indicate 

the status of the power, the connection/link to Flowire, and whether data is 

transmitted on Flowire or not

LED1 - Power

:

 

This LED is lit when the converter is receiving enough 

power for powering up. 

LED2 - Link

This LED is lit when the converter recognizes one or more 

converters on the Flowire star configuration. 

LED3 - Activity

: T

his LED is lit when data is transmitted to or from the 

converter.

3.4  Password Reset Button

Pressing and holding this button for more than 15 seconds will reset the 

NMK password to the default: 

HomePlugAV0123

In addition to reseting the NMK password to its default, the procedure will 

also set the following factory defaults:

 

● DHCP will be turned on

 

● IGMP snooping querier will be turned on

Summary of Contents for Vingtor Stentofon FCDC1

Page 1: ...Configuration Manual Flowire Converter FCDC1 FCDC2 A100K11422 TECHNICAL MANUAL...

Page 2: ...el Ex EAPFX 1 1023221511 Exigo Access Panel Ex EAPFX 6 1023221516 Publication Log Ver Date Author Status Comments 1 5 7 2013 HL HKL Published 2 1 13 4 2016 HKL Published FCDC1 restrictions 3 2 5 2017...

Page 3: ...2 Cables Bandwidth 14 5 3 Collecting Trace Logs 14 A Power Consumption Distances for Typical Cables 16 B Advanced Configuration 17 B 1 Setting a Static IP Address 17 B 2 Disabling DHCP 18 B 3 Network...

Page 4: ...2 3 4 5 Password Reset Button 4 Ethernet Port 5 Figure 1 FCDC1 Flowire Converter There are two models of the Flowire Converter Model Description FCDC1 24 48 VDC Flowire Converter with power forwardin...

Page 5: ...digital telephone systems The above solutions typically use a conventional star wired telecom infrastructure with 0 5 mm2 20 AWG single pair twisted cables 1 2 2 Remote IP Intercom Locations In New Bu...

Page 6: ...e 3 Conventional star wired infrastructure In this solution you will have a centralized equipment rack with the following equipment Telecom Intercom Exchange Power Supply Unit Main Distribution Frame...

Page 7: ...junction boxes and grounded in the central device only Never use a cable run where the voltage drops below half of the PSU voltage Do not connect more than 10 Flowire Converters on one Flowire star co...

Page 8: ...ulti pair cables for one Flowire star configuration has to be gathered in the central FCDC2 This can be done directly in the FCDC2 if the plug has room for it on connector rails or by some other means...

Page 9: ...L DO NOT use FCDC1 to connect to local power for intercoms at remote locations L L Maximum number of Flowire devices per star configuration 10 L L DO NOT use Gigabit switch with FCDC1 as this will dam...

Page 10: ...require its own FCDC1 Flowire Converter To support the Flowire interface the central equipment rack must be equipped with an FCDC2 Flowire Converter Figure 8 Cabling in Ex Industrial Zones L L Ex dev...

Page 11: ...thernet ports If the station has a 24V input the current can be reduced to 24 volts by separating the spare pairs from the CAT cable and connecting it to this input L L DO NOT power the Flowire Conver...

Page 12: ...perature of maximum 55 C Make sure that there is sufficient space for cables and maintenance When using more than one Flowire Converter try to mount them as far apart as possible Figure 9 Flowire Conv...

Page 13: ...power a Vingtor Stentofon IP Intercom Station through its Ethernet port we recommend at least 40V at the remote site For land based installations use XP power PSU for FCDC1 Flowire XP 120 XP Power Sup...

Page 14: ...Converters however will get better bandwidth when more wires are connected between them Avoid unnecessary splicing A continuous cable will carry the signal further Regarding EMI twisted shielded cabl...

Page 15: ...15 Flowire Converter Configuration Manual A100K11422...

Page 16: ...uctor thickness described as diameter and AWG Cable Type Resistance Intercom Intercom Power Consumption 40V 0 5 mm2 20 AWG 37 8 Ohm km Turbine Compact Normal 10W 420m 0 5 mm2 20 AWG 37 8 Ohm km Turbin...

Page 17: ...d as described in section B 2 Disabling DHCP B 1 Setting a Static IP Address By default all Flowire devices have 169 254 1 10 as a static IP address In order to set a new static IP address 1 Isolate t...

Page 18: ...urn off the DHCP client on the device this can be done via the device web interface To disable DHCP Click Toggle DHCP DHCP will be disabled or enabled depending on the previous state The DHCP enabled...

Page 19: ...n To set a new NMK password 1 Log into the Flowire device by entering its IP address e g 10 5 202 80 in a web browser 2 Click the Upgrade form button 3 Enter a new password in the Flowire NMK field 4...

Page 20: ...an IGMP querier do not enable IGMP querier in any of the Flowire units 2 1 2 IGMPv2 Compatability Current versions of Cisco industrial switches only handle IGMPv2 Therefore the Cisco switch should be...

Page 21: ...o optimize availability it is recommended to always configure the FCDC2 in the rack to be CCo Due to its location it is least likely to suffer damage If this Flowire unit fails the star configuration...

Page 22: ...rsion 4 x installed from factory and can be upgraded via the web interface or via the VS IMT tool Hardware version 0104 Item no 1008080110 0104 and older has version 1 x or 2 x installed from factory...

Page 23: ...al A100K11422 After the Flowire devices have been discovered Select all Flowire devices Click NEXT twice skipping STEP 2 Identify stations Make sure the correct Flowire software is selected CTRL Click...

Page 24: ...nfiguration Manual Click the Upgrade button to start the process The upgrade process should take about 1 minute per Flowire device When the upgrade progress bar is at 100 Click NEXT twice Click FINISH...

Page 25: ...etup Start the Tftpd program on the PC In the TFTP server Browse to the directory where the Flowire software is stored Make sure that the correct Server interface is selected C 2 2 Flowire Device Web...

Page 26: ...ts to factory setting L L For Full upgrade resetting the device to factory default setting also implies changing the NMK password to its factory default By doing so all communication with the connecte...

Page 27: ...part or in whole must include this legend Zenitel All rights reserved customer service zenitel com DOC NO A100K11422 The WEEE Directive does not legislate that Zenitel as a producer shall collect end...

Reviews: