background image

better together

Safety, Installation and Operations Manual

Submersible electric pumps

Summary of Contents for Blue Series

Page 1: ...better together Safety Installation and Operations Manual Submersible electric pumps...

Page 2: ...6 and ISO IEC 80079 37 2016 The aforesaid equipment has been approved by the following certification procedures ATEX type examination certificate Volountary request of Directive 2014 34 EU No EPTI 16...

Page 3: ...and maintenance staff 4 1 3 2 Personal protective equipment PPE to use 4 1 3 3 Residual risks 4 1 4 Storage 4 1 5 Disposal 5 2 PRODUCT DESCRIPTION INTENDED USE 5 2 1 Operating conditions 5 2 2 Equipm...

Page 4: ...l documentation supplied with the product especially the electrical wiring diagrams 1 3 2 Personal protective equipment PPE to use Handle the electric pump while wearing personal protective equipment...

Page 5: ...not take in air and the pump will operate correctly For correct use comply with the following operating conditions Duty type S1 Degree of protection IP 68 10m 168 h Maximum immersion depth 7 m Ambien...

Page 6: ...te of conformity 16 year in which the certificate was issued ATEX 0228 ATEX certificate number X specific conditions of use The certificate number indicated on the nameplate is followed by an X It mea...

Page 7: ...C protection class against electric shock 16 IP code degree of protection provided by enclosure 17 Run capacitor 18 Ambient temperature liquid 19 Motor reference standards 20 Minimum flow rate 21 Maxi...

Page 8: ...n is correct To check the rotation direction proceed as follows Lay the pump horizontal on one side and leave it free Temporarily connect the yellow green wire to ground and then connect the power sup...

Page 9: ...enly restart Single phase motors have the thermal protector connected in series to the main circuit to directly cutting off the motor supply in case of overheating Three phase motors have thermal prot...

Page 10: ...tergent before doing any work on it After prolonged use the surface of the pump may become very hot allow it to cool sufficiently to avoid burns Always comply with the safety regulations in force in t...

Page 11: ...ay Set the relay in accordance with the rated current on the name plate 4 Tripped residual current device RCD Low motor winding insulation Contact an authorised service center Fault in cable Have the...

Page 12: ...ubber 5 Screws Stainless steel 6 O Ring Rubber 7 Cable gland Plastic rubber 8 Cable fastener Plastic 9 Cable gland support Plastic 10 Capacitor Plastic metal rubber 11 Motor case Cast iron 12 Bleeder...

Page 13: ...teel 5 O Ring Rubber 6 Cable gland Plastic rubber 7 Cable fastener Plastic 8 Cable gland support Plastic 9 Capacitor Plastic metal rubber 10 Motor case Cast iron 11 Stator Cupper iron 12 Support washe...

Page 14: ...better together 14 Safety Installation and Operations Manual Original instructions...

Page 15: ......

Page 16: ...zenit com DS02 Cod 27270100700400000 Rev 5 01 07 22 DS00 Cod 2727NN00025 Rev 0 20 11 22 better together...

Reviews: