Zelmer ZPG6054MP User Manual Download Page 36

36

PG-003_v02

Before installing make sure that the local distribution 

 

conditions (the type of gas, its pressure) and the 

appliance adjustment are compliant.
The conditions of gas adjustment of the appliance are 

 

indicated on the nameplate.
The appliance is not connected to the fumes conduits. 

 

It should be installed and connected according to 

the binding installation regulations. The appropriate 

requirements concerning ventilation should be taken into 

consideration.
The 

fl

 exible gas connection shall be assembled such 

 

way, that it is not in contact with the furniture parts in 

move (i.e. drawer) and it shall be not located in the are 

with not enough space.
The wiring supplying the power to the hob shall be 

 

secured with properly selected safety device.
Upon installing the hob, the installer is obliged to check 

 

the tightness of the gas 

fi

 tting.

REMARK: The installer is obliged to 

fi

 ll in the warranty 

card, which is the basis for the warranty and guaranty.

Replacing the nozzles for the other  
type of gas 

(Fig. B)

ATTENTION: The hob nozzles replacing can be 

executed only by an authorised quali

fi

 ed installer.

The gas hob is the nozzles are defaulted for 2E (G20) gas. 

The other kinds of gas are:

BURNER

GAS

PRESSURE

NOZZLE 

MARKING

THERMAL 

CAPACITY

WOK

2E (G20)

3B/P (G30)

20 mbar

37 mbar

1.36

0.86

3300 W

LARGE

2E (G20)

3B/P (G30)

20 mbar

37 mbar

1.18

0.72

2500 W

MEDIUM

2E (G20)

3B/P (G30)

20 mbar

37 mbar

0.92

0.58

1500 W

SMALL

2E (G20)

3B/P (G30)

20 mbar

37 mbar

0.75

0.49

1000 W

1

 Remove the cap and crown.

2

 Unscrew the nozzle using a special spanner.

3

 Replace the nozzle screwing the appropriate one 

according to the table.

After the nozzles exchange adjust the burners (see 

”FLAME ADJUSTMENT”.

Upon nozzles replacement glue an adequate label 

indicating the gas type near the end of shaft connecting 

the hob manifold.

Technical specifi cation

The technical parameters of the hob are indicated at the 

nameplate of the appliance.  
The hob is equipped with a shaft with threaded end of G1/2” 

diameter for connecting to gas supply 

fi

 tting. In case of 

connection to LPG cylinder (propane –butane) the ending 

of the 

fl

 exible hose 

 8 x 1mm is screwed on the threaded 

shaft end.
The gas hob is the 1st class appliance equipped with 

a connecting cord with protecting stand. It requires 

connection to the socket equipped with an earth pin.
the appliance meets the requirements of the standards in 

force.
The appliance is in conformance with the requirements of the 

following directives:

Appliances burning gaseous fuels – 90/396/EEC, 

 

93/68/EEC.

Low Voltage Devices (LVD) – 2006/95/EC.

 

Electromagnetic compatibility (EMC) – 2004/108/EC.

 

The product has been labelled with CE mark on the 

nameplate.

The appliance outline  

(Fig. D)

1

 Large burner 

Ø 100 mm 

2.5 kW

2

 Medium burner 

Ø 75 mm 

1.5 kW

3

 Small burner 

Ø 55 mm 

1.0 kW

4

 WOK burner 

Ø 130 mm 

3.3 kW

5

 Burner control knobs with electric ignition candle

6

 Burner grate

7

 Burner cap

8

 Burner crown

9

 Burner body

10

 Ignition candle

11

 Anti-gas 

fl

 ow security device

Flame adjusting 

(Fig. C)

1

 Switch on the burner and set the minimum 

fl

 ame   .

2

 Remove the ring knob from the spindle.

3

 Adjust the 

fl

 ame turning the screw inside the spindle with 

an appropriate screwdriver.

Check if the 

fl

 ame is not off in case of fast switching 

from   maximum to   minimum 

fl

 ame.

In case of 3B/P (G30) gas, the screw must be screwed 

until it turns(clockwise).

Summary of Contents for ZPG6054MP

Page 1: ...XP 10 13 HU HASZN LATI UTAS T S G zf z lap ZPG6054MP ZPG6065MP ZPG6094XP ZPG6105XP T pus 14 17 RO INSTRUC IUNI DE UTILIZARE Plita pe gaz Tip ZPG6054MP ZPG6065MP ZPG6094XP ZPG6105XP 18 21 RU T ZPG6054M...

Page 2: ...2 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A PL...

Page 3: ...wykwalifikowan osob w celu unikni cia zagro enia Napraw urz dzenia mo e dokonywa jedynie przeszko lony personel Nieprawid owo wykonana naprawa mo e spowodowa powa ne zagro enie dla u ytkownika Dysze p...

Page 4: ...PALNIK GAZ CI NIENIE OZNACZENIE DYSZY OBCI ENIE CIEPLNE WOK 2E G20 3B P G30 20 mbar 37 mbar 1 36 0 86 3300W DU Y 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W REDNI 2E G20 3B P G30 20 mbar 37 mbar 0...

Page 5: ...i Powierzchni p yty czy za pomoc wilgotnej szmatki zamoczonej w ciep ej wodzie z dodatkiem p ynu do mycia naczy Mo esz u y specjalnego preparatu do czyszczenia stali nierdzewnej Ruszty przykrywki oraz...

Page 6: ...6 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A proud n vzduchu t sn n CZ...

Page 7: ...e se hork ch st spot ebi e Hroz nebezpe pop len P ed i t n m nechejte spot ebi vystydnout Nenech vejte spot ebi se zap len mi ho ky bez dozoru zejm na b hem sma en proto e p eh t tuk se m e vzn tit K...

Page 8: ...mm Plynov varn deska je spot ebi t dy I vybaven p vod n m kabelem s ochrann m vodi em Je nutn ji zapojit do z suvky s ochrann m kol kem Spot ebi spl uje po adavky platn ch norem Spot ebi vyhovuje po a...

Page 9: ...ejte do sb ren PE k op tn mu zu itkov n Po ukon en ivotnosti spot ebi zlikvidujte prost ednictv m k tomu ur en ch recykla n ch st edisek Pokud m b t spot e bi definitivn vy azen z provozu doporu uje s...

Page 10: ...10 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A pr denie vzduchu tesnenie SK...

Page 11: ...pou vate a Pou vajte iba origin lne dostupn v autorizovan ch servisoch d zy oto n prep na e a ro ty V pr pade poruchy sa obr te na pecializovan servis Niektor prvky sa po as prev dzky varnej dosky ro...

Page 12: ...Po v mene d z treba hor ky nastavi pozrite REGUL CIA PLAME A Po v mene d z nalepte vhodn etiketu s uveden m druhom plynu pri pr pojke varnej dosky Technick daje Technick parametre s uveden na v robno...

Page 13: ...e Obalov materi l nevyhadzujte Obaly a baliace prostriedky elektrospotrebi ov ZELMER s recyklovate n a z sadne by mali by vr ten na nov zhodnotenie Kart nov obal odovzdajte do zberne star ho papiera V...

Page 14: ...14 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A l g ramlat t m t s HU...

Page 15: ...lyz gombokat r csokat haszn lja Ha a k sz l k m k d s ben zavar l pne fel azt javasol juk hogy egy m rkaszerv zhez forduljon Bizonyos elemek felmelegedhetnek a f z lap munk ja sor n Ne rintse meg a fo...

Page 16: ...l csavarozza ki a f v k t 3 Csavarozza be az adatt bl nak megfelel f v k t Af v k k cser je ut n ll tsa be az g ket l sd AL NG BE LL T SA t Af v k k cser je ut n a g zcsatlakoz melletti adatt b l t cs...

Page 17: ...lap fel let t mosogat szeres meleg v zzel benedve s tett ruh val t r lje le Sz ks g eset n haszn ljon speci lis korr zi mentes ac l tiszt t szert A r csokat az g fedeleket valamint g koron kot tiszt t...

Page 18: ...18 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A circula ia aerului garnitur RO...

Page 19: ...buie nlocuit la produc tor ntr un atelier de repara ii speci alizat sau de c tre o persoan calificat Repara iile aparatului pot fi efectuate numai de c tre o persoan calificat Repara iile efectuate n...

Page 20: ...iberat garan ia Schimbarea jiclorului pentru alt tip de gaz Desen B ATEN IE Schimbarea jiclorului poate fi efectuat numai de c tre un instalator autorizat care posed calificarea necesar Din fabric jic...

Page 21: ...de fierbere aduce i butonul n pozi ia minimum acoperi i ntotdeauna vasul cu un capac n cazul unei pene n alimentarea cu energie pute i aprinde arz torul cu un chibrit Nu a eza i vase pe dou arz toare...

Page 22: ...22 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A 2 5 0 5 500 473 50 100 100 553 590 50 76 RU 50...

Page 23: ...23 PG 003_v02 RU Zelmer Zelmer A 1 2 3 4 4...

Page 24: ...E G20 3B P G30 20 37 1 36 0 86 3300W 2E G20 3B P G30 20 37 1 18 0 72 2500W 2E G20 3B P G30 20 37 0 92 0 58 1500W 2E G20 3B P G30 20 37 0 75 0 49 1000W 1 2 3 G1 2 8 x 1 I 90 396 EEC 93 68 EEC LVD 2006...

Page 25: ...25 PG 003_v02 D 1 100 2 5 2 75 1 5 3 55 1 0 4 130 3 3 5 6 7 8 9 10 11 C 1 2 3 3B P G30 10 15 1 1 130 mm 240 260 mm 100 180 260 mm 75 120 220 mm 55 80 160 mm 2 3 PE...

Page 26: ...26 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A 2 5 0 5 500 473 50 100 100 553 590 50 76 50 BG...

Page 27: ...27 PG 003_v02 BG Zelmer Zelmer A 1 2 3 4 4...

Page 28: ...bar 37 mbar 1 36 0 86 3300W 2E G20 3B P G30 20 mbar 37 mbar 1 18 0 72 2500W 2E G20 3B P G30 20 mbar 37 mbar 0 92 0 58 1500W 2E G20 3B P G30 20 mbar 37 mbar 0 75 0 49 1000W 1 2 3 G1 2 8 x 1 90 396 EEC...

Page 29: ...29 PG 003_v02 D 1 100 mm 2 5 kW 2 75 mm 1 5 kW 3 55 mm 1 0 kW 4 130 mm 3 3 kW 5 6 7 8 9 10 11 C 1 2 3 3B P G30 10 15 1 1 130 mm 240 260 mm 100 200 220 REDNI 75 160 180 55 100 140 2 3...

Page 30: ...30 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A 2 5 0 5 500 473 50 100 100 553 590 50 76 50 UA...

Page 31: ...31 PG 003_v02 UA Zelmer Zelmer A 1 2 3 4 4...

Page 32: ...P G30 20 mbar 37 mbar 1 18 0 72 2500W 2E G20 3B P G30 20 mbar 37 mbar 0 92 0 58 1500W 2E G20 3B P G30 20 mbar 37 mbar 0 75 0 49 1000W 1 2 3 G1 2 8 x 1 I 90 396 EEC 93 68 EEC LVD 2006 95 EC EMC 2004 10...

Page 33: ...33 PG 003_v02 3B P G30 10 15 1 i 1 130 mm 240 260 mm 100 180 260 mm 75 120 220 mm 55 80 160 mm 2 3 a PE 26663 19848 5 40 1 15150...

Page 34: ...34 PG 003_v02 D B C 7 8 10 11 9 5 5 4 2 1 3 2 2 6 3 A airflow seal EN...

Page 35: ...gs available in authorised service outlets In case of any defects please contact service desk Some elements get hot during the hob operation Do not touch the hot parts of the appliance Burns hazard Le...

Page 36: ...wing the appropriate one according to the table After the nozzles exchange adjust the burners see FLAME ADJUSTMENT Upon nozzles replacement glue an adequate label indicating the gas type near the end...

Page 37: ...ameter Never try to repair the hob yourself Cleaning and maintenance Remember to keep the hob clean on a regular basis Clean the surface of the hob plate with a damp cloth moistened with warm water co...

Page 38: ...PG 003_v02...

Page 39: ...PG 003_v02...

Page 40: ...PG 003_v02...

Reviews: