background image

 

 

 

Zektor 2CAT™ 

Z57BD2C 

 

HDMI™ 1.3 over CAT5 Extender with   

Bi-directional IR Pass-through 

 
 

User

 

Manual

 

 

 

 
 
 
 
 
 
 

Assembled in the USA 

Designed by you. Built by us. ™ 

Summary of Contents for 2CAT Z57BD2C

Page 1: ...Zektor 2CAT Z57BD2C HDMI 1 3 over CAT5 Extender with Bi directional IR Pass through User Manual Assembled in the USA Designed by you Built by us...

Page 2: ...jury and to minimize the risk of damage to the unit z Follow all instructions and warnings marked on this unit z Do not attempt to service this unit yourself except where explained in this manual z Pr...

Page 3: ...the HDMI source device or capturing IR packets to bypassing IR signals to nearby IR equipped devices The transmission distance between the sending and receiving units can be up to 60m 200ft under HD r...

Page 4: ...al Input 1x HDMI 1x 3 5mm 1x RJ 45 1x 3 5mm Output 1x RJ 45 1x 3 5mm 1x HDMI 1x 3 5mm HDMI source control Controllable via Bi directional IR pass through path IR remote control Electro optical charact...

Page 5: ...he extension cable of IR blaster 3 HDMI IN Connect to a HDM I source with a HDM I male male cable here Rear Panel Transmitting Unit Z57BD2C TX 1 3 2 4 5 4 A V SIGNAL Plug in a Cat 5 5e 6 cable that ne...

Page 6: ...cable of IR blaster 8 HDMI OUT Connect to a HDMI display with a HDMI male male cable here Rear Panel Receiving Unit Z57BD2C RX 6 8 7 9 10 9 A V SIGNAL Plug in a Cat 5 5e 6 cable that needs to be linke...

Page 7: ...Data1 Pin 11 TMDS Clock Shield Pin 18 5 V Power Pin 5 TMDS Data1 Shield Pin 12 TMDS Clock Pin 19 Hot Plug Detect Pin 6 TMDS Data1 Pin 13 CEC Pin 7 TMDS Data0 Pin 14 Reserved N C on device CAT5 RJ 45 P...

Page 8: ...e HDMI source devices CAUTION Incorrect insertion for IR blaster and IR receiver to wrong 3 5mm infrared sockets may result in the failure of the IR extenders Please check carefully before plugging in...

Page 9: ...ly make the IR receiver directly point to the user 5 Connect two CAT5e 6 cables between the transmitting and receiving units via A V SIGNAL and CTRL CHANNEL ports respectively 6 Make sure your Cat 5 5...

Page 10: ...lded twisted pairs of wires in Cat 5 5e 6 cable shielded STP cables are better suited than unshielded UTP cables to improve EMI problems which is worsen in long transmission 6 Because the quality of t...

Page 11: ...ree to insure the unit or assume the risk of loss or damage in transit Under no circumstances will a unit be accepted without a return authorization number The warranty is in lieu of all other warrant...

Reviews: