background image

ZEISS Supreme Prime

Mount Change Instructions

Summary of Contents for Supreme Prime

Page 1: ...ZEISS Supreme Prime Mount Change Instructions...

Page 2: ...nical Data 5 Changing the Mount of a ZEISS Supreme Prime 6 Detaching a Mount 6 Attaching a Mount 10 Adjusting a ZEISS Supreme Prime to Your Digital Camera 15 Testing the Sharpness 16 Correcting the Fl...

Page 3: ...bol indicates that under certain circumstances you can skip certain steps The result symbol indicates information about the obtained result of a step The warning symbol indicates dangerous situations...

Page 4: ...25 mm T1 5 T1 5 to T22 0 26 m 10 119 mm 4 7 95 mm 3 7 1 42 kg 3 13 lbs 70 8 52 3 Supreme Prime 29 mm T1 5 T1 5 to T22 0 33 m 13 121 mm 4 8 95 mm 3 7 1 61 kg 3 55 lbs 64 46 8 1 Close focus distance is...

Page 5: ...ZEISS Supreme Prime Lens In this chapter you learn how to change the mount of a ZEISS Supreme Prime The procedure consists of two parts which are both mandatory to successfully change a mount You lea...

Page 6: ...d in order to prevent the lens from tilting and falling over Ensure that the environment is clean and free from dust so that no dust particles enter the ZEISS Supreme Prime Ensure that the front lens...

Page 7: ...er varies The black inner ring is securely fastened to the mount at the ZEISS factory and does not need to be removed This also applies to the electrical interface The mount is now loose You can now s...

Page 8: ...t for the first time do not remove the shims Never remove the small screw in the groove of the lens 4 Carefully detach the mount from your ZEISS Supreme Prime If you are changing from a PL mount you c...

Page 9: ...Ensure that the environment is clean and free from dust so that no dust particles enter the ZEISS Supreme Prime Ensure that the front lens cap sits on your ZEISS Supreme Prime in order to avoid scratc...

Page 10: ...Prime 3 I PL mount Place the PL mount on the ZEISS Supreme Prime in such a way that the recess of the mount lays on top of the electrical interface The groove on the other side of the PL mount should...

Page 11: ...L mount on the ZEISS Supreme Prime in such a way that the recess of the mount lays on top of the electrical interface The groove on the other side of the LPL mount should then also lay on top of the s...

Page 12: ...P 3 to Your Digital Camera In the following chapter you learn how to adjust your ZEISS Supreme Prime to a digital camera This is necessary to ensure that the ZEISS Supreme Prime works properly and del...

Page 13: ...ies Testing the Sharpness 1 Fasten the siemens star test chart on a wall 2 Mount the ZEISS Supreme Prime on the camera 3 Mount the camera on a tripod 4 Position your camera at the testing distance of...

Page 14: ...Select the maximum magnification of the live view 9 Make sure that the center of the image aligns with the center of the siemens star test chart 10 Set the focus ring according to the testing distance...

Page 15: ...pter Detaching a Mount 3 Determine the total thickness of the shims that already lay in the lens groove 4 Increase or decrease the total shim thickness according to the tables in the appendix by using...

Page 16: ...f chapter Attaching a Mount to attach a new mount 7 Recheck the sharpness of the lens Follow the steps of testing the sharpness once more a If the testing distance has changed follow the steps of chap...

Page 17: ...n Reduce the flange focal distance Add Shims Meter distance scale Feet distance scale Distance to test chart mm 3000 Distance to test chart ft 10 Object distance at best focus mm Change of total washe...

Page 18: ...18 2970 0 04 9ft 10 1 2 0 05 2980 0 02 9ft 11 0 03 2990 0 01 9ft 11 1 2 0 02 3000 0 00 10ft 0 0 00 3010 0 01 10ft 1 2 0 02 3020 0 02 10ft 1 0 03 3030 0 04 10ft 1 1 2 0 05 3040 0 05 10ft 2 0 06...

Page 19: ...me 4047865905114 Rear Lens Cap PL 4047865900577 IMS LPL XD eXtended Data T1 5 135 T1 8 150 000000 2329 934 IMS LPL XD eXtended Data T1 5 21 000000 2330 031 IMS LPL XD eXtended Data T1 5 25 T1 5 29 T1...

Page 20: ...lange to film distance flange focal depth flange back distance flange focal length Shim washer Index mark aperture indicator aperture line aperture mark aperture index Flat blade screwdriver slotted s...

Page 21: ...21 Carl Zeiss AG Consumer Products Carl Zeiss Stra e 22 73446 Oberkochen Germany www zeiss com cine...

Reviews: