6 - EN
2 Technical specifications
Q 350
Q 450
Q 600
Performance
Minimal airflow when preheater is off
75m
3
/h
75m
3
/h
75m
3
/h
Minimal airflow when preheater is on
100m
3
/h
100m
3
/h
100m
3
/h
Maximal airflow
350m
3
/h
450m
3
/h
600m
3
/h
Thermal Efficiency
(According to EN 13141-7:2010)
92%
90%
89%
Electrical data
Maximal power including pre-heater
(At -15°C and max airflow)
1850W
10.00A
2240W
10.80A
2620W
12.70A
Maximal power excluding pre-heater
180W
1.42A
250W
1.98A
350W
2.77A
Power supply / power cord
230V±10%, single phase, 50Hz
Cos
φ
0.36 - 0.54
0.32 - 0.57
0.4 - 0.62
Internal fuse
F5010
(10A)
F5015
(16A)
F5015
(16A)
Connection data
Air connection size (Ø)
Inside: 160mm
Outside: 190mm
Inside: 160mm
Outside: 190mm
Inside: 180mm
Outside: 200mm
Condensation drain size (Ø)
Tube version: 32mm
Thread version: 1¼”
ComfoNet data
Maximal power
400mA@12V
Maximal non powered devices
4
Cable type
2x unshielded twisted pair,
stiff (solid) wires 0,6mm
2
(max 50m)
Color code
12V: red
GND: black
CAN_H: yellow
CAN_L: white
Material specifications
Housing
Coated Sheet Steel
Interior
EPP and ABS
Heat Exchanger
Polystyrene
Enthalpy Exchanger
Polyethylene-polyether-copolymer
General
IP classification
IP40
ISO classification
B
Temperature range during tansport and
storage
-40°C tot +60°C
Temperature range moved air
-20°C tot +60°C
Temperature range installation area
0°C tot 45°C
Relative air humidity installation area
<90%; non-condensing
Weight
50kg
Filter class
Outdoor air: F7
Extract air: G4