TECHNICAL DATA 
 
Limit values: 
- minimum revs 

200 RPM 

- maximum revs 

20000 RPM 

- minimum supply voltage 

7 Volts 

- maximum supply voltage 

18 Volts 

- stand-by current draw  

                    < 0.05 Amp 

- current draw at 1300 RPM 

< 0.3 Amp 

- current draw at 12000 RPM 

< 1.5 Amp  

- maximum continuous current for shift light and power jet output 

1 Amp  

- peak current for shift light and power jet output  

5 Amp 

- constant spark energy from idle to 13000 RPM 

>35mJ 

 
Circuit is protected against reverse supply voltage (wrong connection). 
 
Features: 
- fast power-up (also starts only with condenser) 
- full power starting spark energy already at 7Volts power supply 
- one isolated input (pickup) 
- two independent ignition coil outputs 
- individual advance/retard of each output 
- store and load function for two ignition maps 
- external switch for changing ignition map while riding 
- TPS input (Throttle Position Sensor) 
- shift light output 
- 2 power jet outputs 
- duty cycle solenoid output (for regulating A/F ratio on some carburettors) 
- quick shift (shift kill) 
- soft rev limit (three stage rev limit) 
- reduced spark at high revs with closed throttle (TCT mode) 
- tachometer output 
- easy and fast programming on the field, via hand held programmer 
- programming while machine running - you can immediately see effects 
- each curve can be set in 4 to 12 curve points 
- 3D interpolated ignition map, if TPS selected 
- signal delay compensation 

Summary of Contents for PDCI-24

Page 1: ...p also starts only with condenser full power starting spark energy already at 7Volts power supply one isolated input pickup two independent ignition coil outputs individual advance retard of each outp...

Page 2: ...ad Ign Map load select ignition map from 1 to 2 Save Ign Map save new ignition map from 1 to 2 Set Ignition Map ignition map parameters submenu Advance advance retard whole ignition map on both igniti...

Page 3: ...2 second ignition curve point Exit exit submenu Important To avoid wrong processing don t make unreasonable curve course Every time you make any changes to ignition curve it is automatically saved to...

Page 4: ...NT Move to point you want to change with pressing or and then press enter Now you can change rev point with pressing or in 100 rpm steps and then press enter Now you can change advance angle with pres...

Page 5: ...is retarded Ignition map is unchanged with setting 0 0deg Enter menu and move to Advance with pressing or and then press enter Now you can set advance with pressing or in 0 1deg steps and then press e...

Page 6: ...roboscope lamp Without this compensation ignition advance angle decreasing with rising revs This compensation helps that advance angles in ignition curve are real more accurate How to check if compens...

Page 7: ...ressing or in 100 rpm steps and then press enter 14 3 POWER JET 1 ON TPS if TPS enabled Move to Power Jet 1 ON TPS with pressing or and then press enter Now you can change TPS position with pressing o...

Page 8: ...nts Enter Solenoid Output menu and move to Duty Solenoid with pressing or and then press enter you enterd submenu for setting Duty Solenoid parameters Submenu organisation Curve 0 33 duty cycle curve...

Page 9: ...ine cooling Move to TCT mode with pressing or and then press enter Now you can enable or disable TCT mode with pressing or and then press enter 20 IGN MAP SW Enabling or disabling ignition map switch...

Page 10: ...ce angle you can set with PDCI Calculating mm to deg or vice versa 25 MONITORING Connect programmer to PDCI and wait few seconds for activation of programmer Fist information displayed on the programm...

Reviews: