zeeltronic PDCI-11V User Manual Download Page 1

 

 

- 1 - 

 

www.zeeltronic.com 
[email protected] 
 
updated 06.08.2014 
program version: 25.120326 
 

USER MANUAL  

PDCI-11V PROGRAMMABLE CDI IGNITION AND PV CONTROLLER 

 
 

 

TECHNICAL DATA 
 
Limit values: 
- minimum revs 

280 RPM 

- maximum revs 

20000 RPM 

- minimum supply voltage 

9 Volts 

- maximum supply voltage 

18 Volts 

- max idle current draw  

                     50 mAmp 

- maximum continuous current for shift light and power jet output 

1 Amp  

- peak current for shift light and power jet output  

5 Amp 

- constant spark energy from idle to 20000 RPM 

>65mJ 

 
Circuit is protected against reverse supply voltage (wrong connection). 
 
Features: 
- one channel isolated input (pickup) 
- store and load function for two ignition curves 
- TPS input (Throttle Position Sensor) 
- shift light output 
- 2 power jet outputs 
- quick shift (shift kill) 
- soft rev limit (three stage rev limit) 
- external switch for changing ignition map while riding 
- tachometer output 
- easy and fast programming on the field, via hand held programmer 
- programming while machine running - you can immediately see effects 
- each curve can be set in 4 to 12 curve points 
- 3D interpolated ignition map, if TPS selected 
- signal delay compensation 
- instant monitoring of rev's and angle, via LCD(hand held programmer) 
- programmable power valve actuation 
- store and load function for 5 PV curves 
- external switch for changing PV map while riding 
- programmable PV deviation 
- programmable max close and max open positions 
- self PV test on power-up 

Summary of Contents for PDCI-11V

Page 1: ...pickup store and load function for two ignition curves TPS input Throttle Position Sensor shift light output 2 power jet outputs quick shift shift kill soft rev limit three stage rev limit external s...

Page 2: ...xit 2 MENU ORGANISATION Set Ign set ignition parameters submenu Set PV set PV parameters submenu Exit 2 1 SET IGNITION PARAMETERS SUBMENU Load Ign Map load previously saved ignition curve set from 1 t...

Page 3: ...aved ignition map with pressing or and then press enter 4 SAVE IGN MAP Enter Set Ign menu and move to Save Ign Map with pressing or and then press enter Select position number to which you want to sav...

Page 4: ...r Set Ign menu and move to Ignition Map with pressing or and then press enter You are in submenu for selecting ignition curve Submenu organisation Nr of Points number of ignition curve points from 4 t...

Page 5: ...essing or in 0 1deg steps and then press enter 6 Set ADVANCE With this setting is possible to advance or retard whole ignition curve When setting is positive then ignition curve is advanced and when s...

Page 6: ...set as basic kill time Enter Quich Shift menu and move to Smart Shift with pressing or and then press enter Enable or disable function with pressing or and then press enter 9 Set REV LIMIT Enter Set I...

Page 7: ...off points 12 2 Power Jet 1 Simple Mode Power Jet 1 ON RPM revs for activating power jet 1 Power Jet 1 OFF RPM revs for deactivating power jet 1 Power Jet 1 ON TPS if TPS enabled throttle position fo...

Page 8: ...unning 2 3000RPM off PJ switch off when revs rise and pass 3000rpm PJ switch on when revs drop and pass 3000rpm 3 5000RPM off PJ remain off position 4 8000RPM off PJ remain off position 5 10000RPM off...

Page 9: ...id is used for adjusting A F ratio on some carburettors Enter Solenoid Output menu and move to Output type with pressing or and then press enter Change solenoid Output type with pressing or and then p...

Page 10: ...er or exit calibration with pressing Displayed number should be between 0 and 500 16 Set TPS open 100 if TPS enabled For correct operation TPS open position must be calibrated Enter Set Ign menu and m...

Page 11: ...r 20 Set STOP SWITCH MODE Stop switch can be set as low stop or as high stop Low stop operation engine stops with low level signal stop switch connected to the ground High stop operation engine stops...

Page 12: ...other position number from 1 to 5 24 1 Change Number of Curve Points Move to Nr of Points with pressing or and then press enter Select number of curve points with pressing or and then press enter 24...

Page 13: ...and then press enter PV test can be used for testing or measuring valve position Valve can be moved to any position from 0 to 100 without engine running 29 Set POWER UP Test Enabling or disabling test...

Page 14: ...gle selected ignition curve TPS position depends on setting in the menu Information You can connect or disconnect PDCI unit from programmer any time you want without any harm It is not important if mo...

Reviews: