TECHNICAL DATA
Limit values:
- minimum revs
200 RPM
- maximum revs
20000 RPM
- minimum supply voltage
7 Volts
- recommended power supply voltage
12÷15 Volts
- maximum supply voltage
17 Volts
- stand-by current draw
< 0.05 Amp
- current draw at 1300 RPM
< 0.3 Amp
- current draw at 12000 RPM
< 1 Amp
- maximum continuous current for shift light and power jet output
1 Amp
- peak current for shift light and power jet output
5 Amp
- constant spark energy from idle to 20000 RPM
>70mJ
Features:
- fast power-up (also starts only with condenser)
- full power starting spark energy already at 8Volts power supply
- one isolated input for magnetic pickup
- store and load function for two ignition maps
- external switch for changing ignition map while riding
- TPS input (Throttle Position Sensor)
- shift light output
- power jet output
- duty cycle solenoid output (for regulating A/F ratio on some carburettors)
- quick shift (shift kill)
- soft rev limit (three stage rev limit)
- reduced spark at high revs with closed throttle (TCT mode)
- tachometer output
- easy and fast programming on the field, via hand held programmer
- programming with PC
- programming while machine running
- 3D interpolated ignition map, if TPS used
- signal delay compensation
- instant monitoring of rev's and angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us