TECHNICAL DATA 
 
Limit values: 
- minimum revs 

200 RPM 

- maximum revs 

20000 RPM 

- minimum supply voltage 

8 Volts 

- maximum supply voltage 

16 Volts 

- max. supply voltage for 1 minute 

35 Volts 

- current draw  

                     25 mAmp 

- maximum continuous current for shift light output 

1 Amp  

- peak current for shift light output  

5 Amp 

 
Circuit is protected against reverse supply voltage (wrong connection). 
 
Features: 
- CDI charged from hi voltage charging coils (generator) 
- programmable ignition map (3D interpolated) 
- store and load function for 2 ignition maps 
- one input for magnetic pickup 
- TPS input (ignition map is 3D interpolated above TPS33%) 
- external switch for changing ignition map while riding 
- power jet output 
- quick shift (shift kill) 
- tachometer output 
- advance/retard whole ignition curve 
- programmable timing offset between twin output (RD/RZ500) 
- three stage rev limit (retard timing, reduced spark, spark off) 
- signal delay compensation 
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...) 
- programmable power valve actuation 
- store and load function for 5 PV curves 
- programmable PV deviation 
- programmable max close and max open positions 
- self PV test on power-up 

Summary of Contents for PCDI-24V

Page 1: ...from hi voltage charging coils generator programmable ignition map 3D interpolated store and load function for 2 ignition maps one input for magnetic pickup TPS input ignition map is 3D interpolated...

Page 2: ...g enter Exit menu with selecting Exit 2 MENU ORGANISATION Set Ign set ignition parameters submenu Set PV set PV parameters submenu Exit 2 1 SET IGNITION PARAMETERS SUBMENU Load Ign Curve load previous...

Page 3: ...tion curve set with pressing or and then press enter 5 Set IGNITION CURVE Three ignition curves must be programmed for different TPS positions PCDI does not only switch between ignition curves but als...

Page 4: ...th this setting is possible to advance or retard whole ignition curve When setting is positive then ignition curve is advanced and when setting is negative than ignition curve is retarded With Advance...

Page 5: ...r throttle position is below 90 TPS 8 1 Set POWER JET ON RPM Enter menu and move to Power Jet 1 ON RPM with pressing or and then press enter Now you can change rev limit with pressing or in 100 rpm st...

Page 6: ...ust set flat ignition curve Then measure with stroboscope lamp if mark at flywheel moving when changing revs If mark moving then you must change compensation delay Change Compensation Enter menu and m...

Page 7: ...number to which you want to save your ignition curve set with pressing or and then press enter 18 Set PV Curve Enter menu and move to Set PV Curve with pressing or and then press enter Now you are in...

Page 8: ...ition with pressing or and then press enter Now you can set close position with pressing or and then press enter Max close position is when curve is set to 0 This close position can be moved to any de...

Page 9: ...TPS position Information You can connect or disconnect PCDI unit from programmer any time you want without any harm It is not important if motor running or not and if power supply is connected or not...