www.zeeltronic.com
updated 04.10.2016
firmware version: 20.130426
PROGRAMMING MANUAL FOR HANDHELD PROGRAMMER
PCDI-10T
PROGRAMMABLE CDI IGNITION
TECHNICAL DATA
Limit values:
- minimum revs
200 RPM
- maximum revs
20000 RPM
- minimum supply voltage
8 Volts
- maximum supply voltage
16 Volts
- max. supply voltage for 1 minute
35 Volts
- current draw
25 mAmp
- maximum continuous current for shift light output
1 Amp
Circuit is protected against reverse supply voltage (wrong connection).
Features:
- CDI charged from hi voltage charging coils (generator)
- store and load function for 2 ignition maps
- one input for magnetic pickup
- external switch for changing ignition map while riding
- shift light output
- quick shift (shift kill)
- tachometer output
- advance/retard whole ignition curve
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- monitoring of rev's, ignition angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
Very important!
Resistor spark plugs must be used, because they produce less electromagnetic disturbances.
Very important!
PPV is protected against static discharge, but too high static charge can damage PPV.
Be careful when using programmer on the dyno, because static charge can build up on the bike and
static discharge can damage PPV unit, or programmer. Make ground connection between dyno and
bike frame to prevent static discharge.
1