background image

www.zeeltronic.com

[email protected]

updated 04.10.2016
firmware version: 20.130426

PROGRAMMING MANUAL FOR HANDHELD PROGRAMMER

PCDI-10T

PROGRAMMABLE CDI IGNITION

TECHNICAL DATA

Limit values:
- minimum revs

200 RPM

- maximum revs

20000 RPM

- minimum supply voltage

8 Volts

- maximum supply voltage

16 Volts

- max. supply voltage for 1 minute

35 Volts

- current draw 

                     25 mAmp

- maximum continuous current for shift light output

1 Amp 

Circuit is protected against reverse supply voltage (wrong connection).

Features:
- CDI charged from hi voltage charging coils (generator)
- store and load function for 2 ignition maps
- one input for magnetic pickup
- external switch for changing ignition map while riding
- shift light output
- quick shift (shift kill)
- tachometer output
- advance/retard whole ignition curve
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- monitoring of rev's, ignition angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us

Very important!

Resistor spark plugs must be used, because they produce less electromagnetic disturbances.

Very important!

PPV is protected against static discharge, but too high static charge can damage PPV.
Be careful when using programmer on the dyno, because static charge can build up on the bike and 
static discharge can damage PPV unit, or programmer. Make ground connection between dyno and 
bike frame to prevent static discharge.

1

Summary of Contents for PCDI-10T

Page 1: ...ick shift shift kill tachometer output advance retard whole ignition curve three stage rev limit retard timing reduced spark spark off signal delay compensation timing calculation for every 1 RPM chan...

Page 2: ...t shift light Shift Kill Time shift kill time Rev Limit rev limit Static Angle static angle stator position Compensation signal delay compensation from pickup to spark plug Ign Map SW enable disable i...

Page 3: ...ny changes to ignition curve it is automatically saved to 0 position Then you can save it to any other position number from 1 to 2 Curve Example with six curve points 5 1 Change NUMBER OF IGNITION CUR...

Page 4: ...enter 9 Set REV LIMIT Enter menu and move to Rev Limit with pressing or and then press enter Change rev limit with pressing or in 100 rpm steps and then press enter 10 Set STATIC ANGLE Enter menu and...

Page 5: ...n system Enter Set Ign menu and move to Pulses Per Rev with pressing or and then press enter Change nr of pulses per rev with pressing or and then press enter 14 Set TRIGGER MODE Enter Set Ign menu an...

Page 6: ...is programmed at 1500rpm then below 1500rpm ignition timing is defined with trailing edge of trigger bar idle advance se drawing above and above 1500rmp ignition timing is defined by programmed ignit...

Page 7: ...programmer you can watch revs calculated advance ignition angle and PV valve position Information You can connect or disconnect PCDI unit from programmer any time you want without any harm It is not...

Reviews: