Zebra Economy Mixer Manual

Package Contains:
1. Drum proportioner
2. Suction tube (4 ft.) with foot valve
3. Discharge tube (4 ft.) max length 
for delivery

WEAR 

protective clothing and eyewear when dispensing chemicals or other materials.

ALWAYS 

observe safety and handling instructions of the chemical manufacturers.

ALWAYS 

direct discharge away from you or other persons or into approved containers.

ALWAYS 

dispense cleaners and chemicals in accordance with manufacturer’s instructions. Exercise 

CAUTION 

when maintaining your equipment.

CLEAN 

equipment after each use in accordance with instruction sheet.

WEAR 

protective clothing and eyewear when working in the vicinity of all chemicals, filling or emptying equipment or changing metering tips.

ALWAYS 

re-assemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.

ATTACH 

only to tap water outlets (75 PSI maximum).

Installation and Operation:

1. Select a metering tip (see next section), and insert it into the suction stub. Slide the open end of the suction tube through the 
bung adaptor, then over the suction stub.
2. Slide end of discharge tube over the eductor discharge outlet.
3. Remove either the 3/4 or 2-inch bung from an upright drum.
4. Insert the foot valve end of the suction tube into the drum.
5. Swivel the drum adapter several turns in the bung opening until the bracket is secure.
6. Install minimum 1/2-inch ID water hose between the inlet swivel and water supply spigot. (Minimum 25 PSI flowing water 
pressure is required to operate the unit.)
7. Turn on water supply. To begin dispensing solution, open ball valve at inlet to unit. Do not keep discharge hose in liquid! The 
concentrate will siphon from the container.

Metering Tip Selection:

The final concentration of the dispensed liquid is related to both the size of the metering tip opening (orifice) and the 
viscosity of the liquid being siphoned. If product viscosity is noticeably greater than that of water, consult the procedure for 
Measurement of Concentration on the next page to achieve your desired water-to-product ratio. For waterthin products, use 
the chart below as a guideline. Because such factors as inlet water pressure and temperature can affect dilution ratios, the 
figures listed below are only approximate. Test the actual dilution you are achieving using the Measurement of Concentration 
procedure for best results. Two undrilled, clear tips are supplied for drilling sizes not listed.

THANK YOU FOR YOUR SUPPORT OF OUR PRODUCTS

Please use this equipment carefully and observe all warnings and cautions.

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -  NOTE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 

 

 

 

Decimal 

Approximate Dilution Ratio at

 

Tip Color  

Drill Size   Equivellent 

40 PSI, water-thin viscosity (1.0 cp)

 

No tip  

 

 

4.5:1  or  22.2%

 

Gray  

30 

.1285 

5:1 

 

20.0

 

Black  

40 

.0980 

6:1 

 

16.6

 

Beige  

50  

.0700 

9:1 

 

11.1

 

Red  

55  

.0520 

20:1 

 

5.0

 

White  

57  

.0430 

24:1 

 

4.16

 

Blue  

60  

.0400 

26:1 

 

3.84

 

Tan  

65  

.0350 

31:1 

 

3.23

 

Green  

70  

.0280 

50:1 

 

2.0

 

Orange  

72  

.0250 

70:1 

 

1.43

 

Brown  

74  

.0225 

90:1 

 

1.11

 

Yellow  

76  

.0200 

100:1 

 

1.0

 

Purple  

80  

.0135 

200:1 

 

.50

 

Pink  

87  

.0100 

400:1 

 

.25

4. Metering tip kit (14 tips)
5. Product information sheet

®