Zaxcom Miniature Digital Recorder User’s Manual____________________________________Chapter 5
41
Remote Audio Frequency Change page
Page purpose:
This page sets the transmit frequency for the specified TRX9xx.
Parameters:
(value range: (see
.1
) The frequency range is based on the frequency
The top example is what you should normally see. The bottom example is what you see if you have selected the
ALL choice for Unit Code. Since it‟s a really BAD idea to command all transmitters to start using the same
frequency, this warning basically reminds you to choose a specific unit.
While you are changing the frequency on the display, the command is not sent to the selected TRX9xx transmitter
until you stop on a specific frequency for longer then 1.5 sec. This prevents the TRX9xx unit from transmitting on
all channels between the old and new frequencies. The transmit counter, bottom line right three digits, will
increment and an asterisk (*) will blink, for each message sent (several will be sent each time you press the
INC
or
DEC
button). If you are at the extreme edge of your range, you may need to take additional actions to get the
change to take place (i.e. re-orient your antenna, have talent move closer, etc.).
Remote Power Setting Change page
REMOTE POWERMODE
0: POWER=ON
Page purpose:
This page sets the power setting used by the specified TRX9xx.
Parameters:
6: POWER=LOW2
– Disables the RF Power Amplifier, RF Board and Mic Pre-amp. In most cases, you
want to use
LOW2
if you are using the remote power setting. When using the
LOW2
setting, the TRX9xx draws half the current as the full power setting,
saving battery life.
5: POWER=LOW1
– Disables the RF Power Amplifier in remote units.
4: POWER=ON
– Filler to prevent accidentally turning „OFF‟ the remote unit‟s power.
3: POWER=ON
– Filler to prevent accidentally turning „OFF‟ the remote unit‟s power.
2: POWER=ON
– Filler to prevent accidentally turning „OFF‟ the remote unit‟s power.
1: POWER=ON
– Filler to prevent accidentally turning „OFF‟ the remote unit‟s power.
0: POWER=ON
– Turns the remote unit‟s power fully „ON‟.
NOTE:
If the TRX9xx is not in range of the IFB or is on the fringe of coverage, the power setting command may
have to be repeated.
Timecode Frame-rate page
TIMECODE 30NDF
GEN 00:00:00:00
Page purpose:
This page sets the frame-rate to be transmitted with the timecode.
Parameters:
[
23.98
] / [
24
] / [
25
] / [
29.97NDF
] / [
29.97DF
] / [
30NDF
] / [
30DF
]
The IFB100‟s timecode generator is in Free-Run mode unless it is connected to a timecode source.
If an external timecode source is connected, the IFB100‟s internal timecode generator stays in sync with it. If a
TRX9xx/ZFR100 is in Autoload mode, starting and stopping recording is controlled by the external source.
REMOTE CH 512.0 *
UNIT ID=1 000
TX CH WARNING
UNIT ID = ALL