6.2 Description of Console “RESTORE” function
The RESTORE PARAM function allows transfer of the Console’s stored data into
the memory of the controller. This is achieved in a fast and easy way using the
method previously used with the SAVE PARAM. function.
The data that is available via the RESTORE PARAM. function is as follows:
-
All Parameter Values (PARAMETER CHANGE).
-
Options (SET OPTIONS).
-
The level of the Battery (ADJUST BATTERY).
ATTENTION: When the RESTORE operation is made, all data in the controller
memory will be written over and replace with data being restored.
Flow Chart showing how to use the RESTORE function of the Digital Console.
1) Opening Zapi Display.
AC2 ZAPI V0.0
48V 350A 00000
2) Press ENTER to go into the General menu.
' % '
' ' '
3) The Display will show:
MAIN MENU
PARAMETER CHANGE
4) Press ROLL UP or ROLL DOWN button until
RESTORE PARAM. appears on the Display.
% ' '
% ' '
5) The Display will show:
MAIN MENU
RESTORE PARAM.
6) Press ENTER to go into the RESTORE PARAM.
Function.
' % '
' ' '
7) The Display shows the type of Model stored,
with a Code Number.
SELECT : MOD. 00
AC2 ZAPI V1
8) Keep pressing either ROLL UP and ROLL
DOWN buttons until the desired model appears on
the Display.
% ' '
% ' '
SELECT : MOD. 01
AC2 ZAPI V1
9) Press ENTER to commence the Restore
operation.
' % '
' ' '
10) The Display will ask “ARE YOU SURE?”.
ARE YOU SURE?
YES=ENTER NO=OUT
11) Press ENTER for YES, or OUT for No.
' % '
' ' '
' ' '
' % '
Page - 50/64
ADEZP0AE - AC-2 INVERTER - User Manual
Summary of Contents for AC-2
Page 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Page 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Page 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Page 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...