zapco Z-AP Series Owner'S Manual Download Page 10

*Important Note

: AP amplifiers are stable on 1Ω and 2Ω Bridged only when used with music signal. The limits of the amplifiers to deliver power over time are not dependent on the load impedance, but 

rather on their ability to dissipate the heat produced. If this is not possible, the amplifier will go into protection mode. Furthermore, several protection cycles, repeated in a short time interval, can irreparably 
damage the amplifier.

Technical Specifications

Model 

Z-150.2 AP 

Z-300.2 AP 

Z-600.2 AP 

Z-150.4 AP 

Z-150.6 AP 

Z-1100.1 AP 

Z-2000.1 AP

Type

 

2-Ch, Class AB 

2-Ch, Class AB 

2-Ch, Class AB 

4-Ch, Class AB 

6-Ch, Class AB 

Mono, Class AB 

Mono, Class AB

Power (W) 

Channel/RMS

 

2 x 150 (4Ω) / 2 x 275 (2Ω) / 2 x 500 (1Ω)* 

550 (Br., 4Ω) / 1000 (Br., 2Ω)* 

2 x 300 (4Ω) / 2 x 500 (2Ω) / 2 x 800 (1Ω)* 

1000 (Br., 4Ω) / 1600 (Br., 2Ω)* 

2 x 600 (4Ω) / 2 x 1000 (2Ω) / 2 x 1600 (1Ω)* 

2000 (Br., 4Ω) / 3200 (Br., 2Ω)* 

4 x 150 (4Ω) / 4 x 275 (2Ω) / 4 x 400 (1Ω)* 

2 x 550 (Br., 4Ω) / 2 x 800 (Br., 2Ω)* 

6 x 150 (4Ω) / 6 x 275 (2Ω) / 6 x 500 (1Ω)* 

3 x 500 (Br., 4Ω) / 3 x 1000 (Br., 2Ω)* 

650 (4Ω) / 1100 (2Ω) / 1600 (1Ω)* 

1200 (4Ω) / 2000 (2Ω) / 2400 (1Ω)*

THD

 

< 0.1% 

< 0.1% 

< 0.1% 

< 0.1% 

< 0.1% 

< 0.1% 

< 0.1%

S/N

 

>110dB 

>110dB 

>110dB 

>110dB 

>110dB 

>110dB 

>110dB

Frequency 

Response

 

10Hz ~ 30KHz 

10Hz ~ 30KHz 

10Hz ~ 30KHz 

10Hz ~ 30KHz 

10Hz ~ 30KHz 

10Hz ~ 30KHz 

10Hz ~ 30KHz

Net/Overall  

Dim. (mm, WxHxL)

 

190 x 62 x 300 / 190 x 62 x 328  

190 x 62 x 450 / 190 x 62 x 478 

190 x 62 x 600 / 190 x 62 x 628 

190 x 62 x 440 / 190 x 62 x 468 

190 x 62 x 600 / 190 x 62 x 628 

190 x 62 x 480 / 190 x 62 x 588 

190 x 62 x 600 / 190 x 62 x 628

ARPA of AMERICA, 290 Beeline Dr, Bensenville, IL 60106 - USA 
ARPA of EUROPE, Via Isonzo snc, Centro L’Orologio - 04100 Latina - ITALY 
ARPA of CHINA,

 

东莞市艾柏贸易有限公司

 

Room201,Unit 7, Dahongshan Industrial zone, No.143 Guanlong Road, Guancheng Street, Dongguan City, Guangdong Province, CHINA, 523008

 

地址:广东省东莞市莞城街道莞龙路

143

号大宏山工业区

7

单元

201

室 

 

APEX GROUP - APEX Business Development (ABD) CO LTD, Bright Way Tower, office 04 7/Fl, 33 Mong Kok Road Kowloon City, Hong Kong 999077

 

 

          

fb.com/zapcocaraudio 

          

instagram.com/zapco_official 

 

                                      ZAPCO is a brand of APEX Group © All rights reserved. Manual v.23.09.07

6-Ch. Amplifier - 5-Ch. Mode

 

The most popular system for a six channel amplifier is right/left front, right/left 
rear, and a mono sub. Note the hookup especially of the sub as Ch5+ and Ch6-. 
This gives the sub the combined power of the 2 channels. Note that since the  
sub is a bridged hookup the sub must be 4Ω minimum.

CH1

CH2

CH5

CH3

CH4

CH6

2 OHM MIN/CH

WF

WF

TW

TW

X-OVER

X-OVER

X-OVER

WF

WF

TW

TW

X-OVER

2 OHM MIN/CH

4 OHM 

MIN LOAD

1-Ch. Amplifier 

A simple 1 channel hookup for a single speaker or two speakers. The speakers 
must be 2Ω minimum.

2 OHM MIN

19

18

Summary of Contents for Z-AP Series

Page 1: ...Z AP SERIES Owner s Manual...

Page 2: ...ali DE Allgemeine Anweisungen FR Instructions G n rales ES Instrucciones Generales CH Committed to excellence 7 The Zapco Z AP Series 8 Class Power Heat 10 All wire is not created equal 12 Amplifiers...

Page 3: ...berm ige Vibrationen erzeugen k nnte Verst rkungsanpassung Gain Potentiometer sind keine Lautst rkeregler sie sollten es sein nur dann verwendet werden wenn dies unbedingt erforderlich ist Eine Erh hu...

Page 4: ...rst line developed by listening rather that by measuring That series was favorably compared to the best home amps and quickly went straight to the winner s circle in Audio contests They were called th...

Page 5: ...e output devices faster and increase efficiency we used a new insulator material developed for aerospace At the differential input stage we used 0 1 resistors to assure the lowest possible floor We de...

Page 6: ...rtion is a major reason Zapco amps sound better than others So with Z AP amplifiers consumers have more dynamics plus the sound quality of class A B amplifiers If the Zapco Class A B are used at the m...

Page 7: ...5 amps 6 6 4 4 2 2 2 0 85 105amps 6 6 4 2 2 2 2 0 105 125 amps 4 4 4 2 2 0 0 0 125 150 amps 2 2 2 2 0 0 0 0 Length Wire Sizing Chart All Wire is not created equal Do not use CCA wire with Zapco amplif...

Page 8: ...fier Controls 1 Ch 1 and Ch 2 RCA input connectors using Zapco s proprietary gold plated connectors 2 Pass through RCA outputs so you can daisy chain multiple amps while only running one front to back...

Page 9: ...ing a pair of speakers for the mids and highs on left and right channels and at the same time run a woofer bridged between the L and R terminals as shown However since each channel will see 1 2 the im...

Page 10: ...z 30KHz 10Hz 30KHz Net Overall Dim mm WxHxL 190 x 62 x 300 190 x 62 x 328 190 x 62 x 450 190 x 62 x 478 190 x 62 x 600 190 x 62 x 628 190 x 62 x 440 190 x 62 x 468 190 x 62 x 600 190 x 62 x 628 190 x...

Page 11: ...Modesto California USA Since 1974 zapco com...

Reviews: