BUILDING IN
589
598
594
114
19
21
540
570
558
min. 550
20
600
min. 560
3
9
SECURING THE APPLIANCE TO THE
CABINET
A
B
ELECTRICAL INSTALLATION
The manufacturer is not responsible if
you do not follow the safety
precautions from the Safety chapters.
This appliance is supplied without a main plug and
a main cable.
CABLE
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F, H05
V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total power
on the rating plate.
CONNECTING THE TERMINAL BOARD
The appliance has a six-pole terminal board. The
jumpers (bridges) are set for operation on a 400 V
three-phase with a neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1
2
3
4
5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange the
jumpers on the terminal board (refer to the
connection diagram below). Connect the ground
cable to the terminal. After you connect the supply
cable to the terminal board, attach it with a junction
clamp.
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1
N
L2
L1
N
N
L2
L3
L1 L2 L3
PE
PE
PE
PE