background image

min 20 mm
(max 150 mm)

30 mm

60 mm

B

A

A) Removable panel

B) Space for connections

Kitchen unit with oven

The electrical connection of the hob and the

oven must be installed separately for safety

reasons and to let easy remove oven from the

unit.

Technical information

Hob dimensions

Width

595 mm

Depth

520 mm

Bypass diameters

BURNER

Ø BYPASS 1/100 mm

Rapid

42

Semi-rapid

32

Auxiliary

28

Other technical data

TOTAL POWER:

Gas original:

G20 (2H) 20 mbar = 7,7 kW

Gas replacement:

G30 (3+) 28-30 mbar = 545 g/h

G31 (3+) 37 mbar = 536 g/h

Electric supply:

230 V ~ 50 Hz

3 core flexible cable with non rewireable plug fitted with a 3 amp car-

tridge fuse

Appliance category:

II2H3+

 

Gas connection:

R 1/2"

 

Appliance class:

3

 

14

www.zanussi.com

Summary of Contents for ZGX65414BA

Page 1: ...EN ZGX65414BA User Manual Hob GB ...

Page 2: ...y or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Do not let children play with the appliance Keep all packaging away from children Keep children and pets away from the appliance when it operates or when it cools down Accessible parts are hot If the applia...

Page 3: ... connected to the power supply an all pole isolating switch with a contact gap is required Complete disconnection in compliance with the conditions specified in overvoltage category III must be guaranteed The earth cable is excluded from this When you route the mains cable make sure that the cable doesn t come into direct contact for example using insulating sleeving with parts that can reach temp...

Page 4: ...ation If the mains socket is loose do not connect the mains plug Do not pull the mains cable to disconnect the appliance Always pull the mains plug Use only correct isolation devices line protecting cut outs fuses screw type fuses removed from the holder earth leakage trips and contactors The electrical installation must have an isolation device which lets you disconnect the appliance from the mai...

Page 5: ...lied with the appliance Do not install a flame diffuser on the burner The use of a gas cooking appliance results in the production of heat and moisture Provide good ventilation in the room where the appliance is installed Prolonged intensive use of the appliance may call for additional ventilation for example opening of a window or more effective ventilation for example increasing the level of mec...

Page 6: ...pid burner 3 Auxiliary burner 4 Control knobs Control knob Symbol Description no gas supply off position Symbol Description ignition position maximum gas supply minimum gas supply Daily use WARNING Refer to Safety chapters Burner overview A B D C A Burner cap 6 www zanussi com ...

Page 7: ... in this case approach the burner with a flame push the relevant knob down and turn it counter clockwise to maximum gas supply position Keep the control knob pushed for equal or less than 10 seconds to let the thermocouple warm up If the burner accidentally goes out turn the control knob to the off position and try to light the burner again after minimum 1 minute The spark generator can start auto...

Page 8: ...pplicable Wash stainless steel parts with water and then dry them with a soft cloth Pan supports The pan supports are not resistant to washing in a dishwasher They must be washed by hand 1 Remove the pan supports to easily clean the hob Be very careful when you replace the pan supports to prevent the hob top from damage 2 The enamel coating occasionally can have rough edges so be careful when you ...

Page 9: ...the cause of the malfunction If the fuse releases again and again contact a qualified electrician Burner cap and crown are placed incorrectly Place the burner cap and crown correctly The flame extinguishes imme diately after ignition Thermocouple is not heated up sufficiently After lightning the flame keep the knob pushed for equal or less than 10 seconds The flame ring is uneven Burner crown is b...

Page 10: ...ed in the Republic of Ireland please refer to NSAI Domestic Gas Installation I S 813 Current Editions and the ETCI Rules for Electrical Installations Provision for ventilation Detailed recommendations are contained in the following British Standards Codes Of Practice B S 6172 B S 5440 Par 2 and B S 6891 Current Editions The hob should not be installed in a bed sitting room with a volume of less th...

Page 11: ...steel or copper The connection should be suitable for connecting to R 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak test is carried out on the hob and installation Make sure that the main connection pipe does not exert any strain on the hob If you use flexible metal pipes make sure that they agree to ISO 10380 and ISO 10807 standards Be carefu...

Page 12: ...t electrical installation must agree with the latest I E E Regulations and local Electricity Board regulations For your own safety the installation must be done by a qualified electrician e g your local Electricity Board or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting NICEIC The manufacturer refuses to be held responsible if these safet...

Page 13: ...nnect the green and yellow earth wire to the terminal which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the blue neutral wire to the terminal which is marked with the letter N or coloured blue 3 Connect the brown live wire to the terminal which is marked with the letter L It must always be connected to the network phase There must be no cut or stray stran...

Page 14: ...nformation Hob dimensions Width 595 mm Depth 520 mm Bypass diameters BURNER Ø BYPASS 1 100 mm Rapid 42 Semi rapid 32 Auxiliary 28 Other technical data TOTAL POWER Gas original G20 2H 20 mbar 7 7 kW Gas replacement G30 3 28 30 mbar 545 g h G31 3 37 mbar 536 g h Electric supply 230 V 50 Hz 3 core flexible cable with non rewireable plug fitted with a 3 amp car tridge fuse Appliance category II2H3 Gas...

Page 15: ...mbar G31 37 mbar Rapid 2 7 0 75 86 196 193 Semi rapid 1 9 0 45 71 138 136 Auxiliary 1 0 0 33 50 73 71 ENVIRONMENTAL CONCERNS Recycle the materials with the symbol Put the packaging in applicable containers to recycle it Help protect the environment and human health and to recycle waste of electrical and electronic appliances Do not dispose appliances marked with the symbol with the household waste...

Page 16: ...www zanussi com shop 892962054 A 062014 ...