background image

Allowed ambient temperature

+ 5°C to + 35°C

Level of protection against ingress of solid parti-

cles and moisture ensured by the protective cov-

er, except where the low voltage equipment has

no protection against moisture

IPX4

1) With reference to EN 61121. 8 kg of cotton centrifuged at 1000 rpm.

2) With reference to EN 61121. 4 kg of cotton centrifuged at 1000 rpm.

3) Energy consumption per year in kWh, based on 160 drying cycles of the standard cotton programme at

full and partial load, and the consumption of the low-power modes. Actual energy consumption per cycle

will depend on how the appliance is used (REGULATION (EU) No. 392/2012).

4)

 

CONSUMPTION DATA

Programme

Spun at / residual humidity

Drying time

1)

Energy con-

sumption

2)

Cottons Eco 8 kg

Cupboard Dry

1400 rpm / 50%

125 min.

4,10 kWh

 

1000 rpm / 60%

145 min.

4,81 kWh

Iron Dry

1400 rpm / 50%

97 min.

3,11 kWh

 

1000 rpm / 60%

115 min.

3,82 kWh

Cottons Eco 4 kg

Cupboard Dry

1400 rpm / 50%

71 min.

2,18 kWh

 

1000 rpm / 60%

82 min.

2,52 kWh

Synthetics 3,5 kg

Cupboard Dry

1200 rpm / 40%

55 min.

1,57 kWh

 

800 rpm / 50%

71 min.

1,89 kWh

1) For partial loads, the cycle time is shorter and appliance uses less energy.

2) Improper ambient temperature and/or poorly centrifuged laundry can prolong cycle time and increase

the energy consumption.

PRODUCT INFORMATION SHEET IN REFERENCE TO E.U. REGULATION

1369/2017

Product Information Sheet

 

Trade Mark

ZANUSSI

Model

ZDC8203WZ,

PNC916098489

Rated capacity in kg

8

15

Summary of Contents for ZDC8203WZ

Page 1: ...GETTING STARTED EASY User Manual ZDC8203WZ EN User Manual Tumble Dryer ...

Page 2: ...understand the hazards involved Children between 3 and 8 years of age and persons with very extensive and complex disabilities shall be kept away unless continuously supervised Children of less than 3 years of age should be kept away unless continuously supervised Do not let children play with the appliance Keep all packaging away from children and dispose of it appropriately Keep detergents away ...

Page 3: ...ccessible after installation If the mains power supply cable is damaged it must be replaced by the manufacturer its Authorised Service Centre or similarly qualified persons to avoid an electrical hazard Do not exceed the maximum load of 8 kg refer to the Programme chart chapter Do not use the appliance if items have been soiled with industrial chemicals Wipe away lint or packaging debris that has ...

Page 4: ...t is not adjust the feet accordingly ELECTRICAL CONNECTION WARNING Risk of fire and electric shock The appliance must be earthed Make sure that the parameters on the rating plate are compatible with the electrical ratings of the mains power supply Always use a correctly installed shockproof socket Do not use multi plug adapters and extension cables Do not pull the mains cable to disconnect the app...

Page 5: ...ater supplies Cut off the mains electrical cable close to the appliance and dispose of it Remove the door catch to prevent children or pets from becoming trapped in the drum Dispose of the appliance in accordance with local requirements for the disposal of Waste Electrical and Electronic Equipment WEEE 5 ...

Page 6: ...s to open the bottom cover 7 Adjustable feet 8 Condenser door 9 Locks for condenser door 10 Rating plate For ease of loading laundry or ease of installation the door is reversible see separate leaflet CONTROL PANEL 1 2 3 4 6 5 9 7 8 1 On Off button 2 Programme selection touchpad 3 Dryness selection touchpad 4 Options selection touchpad 5 Time touchpad 6 Start Pause touchpad 7 Delay touchpad 8 Disp...

Page 7: ...cle to be used to dry cotton with cotton cupboard dry ness level with maximum energy saving 8kg Cottons Cycle defined to dry all types of cotton ready to store cup board dry 8kg Synthetics Drying level Extra Dry Cupboard Dry Iron Dry 3 5kg Mix Cotton and synthetic fabrics Low temperature programme Delicate programme with warm air 3kg Easy Iron Easy care fabrics for which a minimum of ironing is ne...

Page 8: ...Cupboard Dry Iron Dry ANTICREASE 90 MIN Extends the anti crease phase by 60 minutes at the end of the drying cycle This function reduces creases The laundry can be removed during the anti crease phase ANTICREASE 60 MIN Extends of 30 minutes the standard anticrease phase 30 minutes at the end of the drying cycle This function prevents the laundry from creases The laundry can be removed during the a...

Page 9: ...the child lock option 1 Press the on off button to activate the appliance 2 Wait approximately 8 seconds 3 Press and hold touchpads C and D at the same time The child lock indicator comes on The child lock indicator comes on It is possible to deactivate the child lock option while a programme operates Press and hold the same touchpads until the child lock indicator goes off BUZZER ON OFF To deacti...

Page 10: ...e programme starts STARTING THE PROGRAMME WITH DELAY START 1 Set the correct programme and options for the type of load 2 Press the delay start button again and again until the display shows the delay time you want to set You can delay the start of a programme from a minimum of 60 minutes to a maximum of 20 hours 3 Press the Start Pause touchpad The display shows the countdown of the delay start W...

Page 11: ...must be faced outwards Always set the programme suitable for the type of laundry Do not put light and dark colours together Use suitable programme for cottons jersey and knitwear to reduce shrinkage Do not exceed the maximum load stated in the programmes chapter or shown on the display Dry only the laundry that is suitable for tumble drying Refer to the fabric label on the items Do not dry large a...

Page 12: ...steam ironing Before you use the water remove dirt residues with a filter CLEANING THE CONDENSER 1 1 1 2 2 1 1 2 3 4 5 6 2 2 1 7 8 CLEANING THE DRUM WARNING Disconnect the appliance before you clean it Use a standard neutral soap detergent to clean the inner surface of the drum and drum lifters Dry the cleaned surfaces with a soft cloth 12 ...

Page 13: ...r is closed The appliance door does not close Make sure that the installation of the filter is cor rect Make sure that the laundry does not catch be tween the appliance door and the rubber seal The appliance stops during operation Make sure that the water container is empty Press Start Pause to start the programme again The cycle time is too long or unsatisfactory dry ing result 1 Make sure that t...

Page 14: ... better setting The airflow slots are clogged Room temperature is too low or too high optimal room temperature 19 C to 24 C TECHNICAL DATA Height x Width x Depth 850 x 600 x 600 mm maximal 665 mm Max depth with the appliance door open 1090 mm Max width with the appliance door open 950 mm Adjustable height 850 mm 15 mm feet regulation Drum volume 118 l Maximum load volume 8 kg Voltage 230 240 V Fre...

Page 15: ...LATION EU No 392 2012 4 CONSUMPTION DATA Programme Spun at residual humidity Drying time1 Energy con sumption2 Cottons Eco 8 kg Cupboard Dry 1400 rpm 50 125 min 4 10 kWh 1000 rpm 60 145 min 4 81 kWh Iron Dry 1400 rpm 50 97 min 3 11 kWh 1000 rpm 60 115 min 3 82 kWh Cottons Eco 4 kg Cupboard Dry 1400 rpm 50 71 min 2 18 kWh 1000 rpm 60 82 min 2 52 kWh Synthetics 3 5 kg Cupboard Dry 1200 rpm 40 55 min...

Page 16: ...otton laundry and it is the most efficient programme in terms of energy con sumption for cotton Weighted programme time of the standard cotton programme at full and partial load in minutes 109 Programme time of the standard cotton programme at full load in mi nutes 145 Programme time of the standard cotton programme at partial load in mi nutes 82 Condensation efficiency class on a scale from G lea...

Page 17: ...Return the product to your local recycling facility or contact your municipal office 17 ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...WWW ZANUSSI COM SHOP 136955600 A 192019 ...