12
Possible cause
Thermostatic control can be set wrongly.
If products are not cold enough or placed wrongly.
The door does not close tightly or it is not shut
properly.
Thermostatic control can be set wrongly.
The door does not close tightly or it is not shut
properly.
Products in big quantity to be frozen were put in.
Products to be frozen are placed too closely to
each other.
It is normal. During automatic defrosting frost melts
on the back plate.
The outlet of the chamber can be clogged up.
Products placed in can prevent water from flowing
into the collector.
The melting water outlet flows not into the
evaporative tray above the compressor.
Products are not wrapped properly.
Doors are not shut properly or do not close tightly.
The thermostatic control can be set wrongly.
The thermostatic control is set wrongly.
Doors are not shut properly or do not close tightly.
Products in big quantity to be frozen were put in.
Too warm food was put in.
The appliance is in too warm place.
Plug is not connected to the mains socket
properly.
The fuse burnt out.
The thermostatic control is not on.
There is no voltage in the mains socket. (Try to
connect another appliance into it.)
The appliance is not supported properly.
Solution
Set the thermostat knob to higher position.
Place the products to the appropriate place.
Check if the door closes well and the gasket is
unhurt and clean.
Set the thermostat knob to higher position.
Check if the door closes well and the gasket is
unhurt and clean.
Wait some hours and then check the
temperature again.
Place the products in a way so that cold air
could circulate among them.
Clean the outlet.
Replace the products so that they can not
touch the back plate directly.
Put the melting water outlet to the evaporative
tray.
Wrap the products better.
Check if the doors close well and the gaskets
are unhurt and clean.
Set the thermostat knob to a position that gives
higher temperature.
Set the thermostat knob to a position that gives
higher temperature.
Check if the doors close well and the gaskets
are unhurt and clean.
Wait some hours and then check the
temperature again.
Put food at max. room temperature.
Try to reduce the temperature in the room
where the appliance stands.
Connect the mains plug properly.
Change the fuse.
Start the appliance according to instructions in
chapter Putting it into use.
Call an electrician.
Check if the appliance stands stable (all the
four feet should be on the floor).
Problem
It is too warm in the
refrigerator.
It is too warm in the freezer.
Water flows at the back plate
of the refrigerator.
Water flows into the chamber.
Water flows onto the floor.
There are too much frost and
ice.
The compressor operates
continually.
The appliance does not work
at all. Neither cooling, nor
lighting works. Indicator lamps
do not give light.
The appliance is noisy.
Inasmuch as the advice does not lead to result, call the nearest brand-mark service.