14
Commissioning
When the hob has been fully installed it will be
necessary to check the minimum flame setting. To do
this, follow the procedure below.
- Turn the gas tap to the MAX position and ignite.
- Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times.
If the flame is unstable or is extinguished follow the
procedure below.
Procedure:
Re-ignite the burner and set to MIN.
Remove the control knob, insert a thin
bladed screwdriver down the hole in the
front panel and turn the adjustment screw
until the flame is steady and does not
extinguish, when the knob is turned from
MIN to MAX. Repeat this procedure for all
burners.
F
Technical Maintenance
Check at regular intervals the condition and
serviceability of the gas connection hose and pressure
regulator, if any is fitted; in case of malfunction, do
not repair but replace the whole faulty part.
To ensure a smooth and safe operation, it is necessary
to periodically grease the gas taps.