LIBERO LINE WOK INDUCTION
A
la
rm
c
ode
Invol
v
e
d
c
om
po
nent
P
owe
r
di
s
a
-
bl
e
S
e
lf
-re
s
e
t-
ti
ng
Alarm name
Alarm description
Alarm trou-
ble shoot-
ing
E701
E702
POW
Tesla
: Yes
Yes
Tesla:
BOARD_FAN_ER-
ROR
Tesla POW:
IGBT cooling fan blocked or not connected. Re-
marks:
•
The alarm is reset when the U.I. stay at least 120sec of
OFF
or
COOLING_DOWN
state, no matter if problem is
solved or not.
•
About 20 sec before the alarm occurs POW sent pot fail
state to the U.I.
Foucault HC:
One or more internal cooling fan blocked/not
connected/not following. Power disable depend on number of
fans blocked
Check cool-
ing fan of
POW
E711
E712
POW
Yes
Yes
EXTER-
NAL_FAN_ALARM
Tesla POW only:
External tangential fan blocked or not con-
nected.
Remarks: The alarm is reset when the U.I. stay at least
120sec of
OFF
or
COOLING_DOWN
state, no matter if prob-
lem is solved or not.
Check cool-
ing fan
E821
E822
U.I
Yes
Yes
POW_COMM_WD
OG_ALM
U.I1 detects POW1/POW2 communication timeout.
The alarm is showed on left display only (Both 821 and 822).
NOTE:
This alarm maybe generated by:
➢
A wrong MACS connection between U.I and POW
➢
A missing or wrong ID jumper on POW board.
With appliance with more than one POW (
e.g.
Double Zone
Fry top) it’s still possible to work with one zone only when the
other one is in error.
Check com-
munication
cables POW
to U.I.
E831
E832
U.I
Yes
Yes
MACS_ACK_TOUT
U.I1 detects MACS acknowledgements missing to POW1.
This alarm appears if communication is lost during standard
operation. The alarm is overridden by E821 after some sec-
onds. The alarm is showed on both display.
Check com-
munication
cables POW
to U.I.
E911
U.I
BUTTON _LOW
_REF
Touch button failure
Check U.I.
E921
U.I
BUTTON _LOW
_SIGNAL
Touch button failure
Check U.I.
E931
U.I
BUTTON _HIGH
_REF
Touch button failure
Check U.I.
E941
U.I
BUTTON _HIGH
_SIGNAL
Touch button failure
Check U.I.
E981
U.I
BUTTON_ERROR -
Init
Touch button failure
Check U.I.
E991
U.I
BUTTON_ERROR
– Run time
Touch button failure
Check U.I.
E9A1
U.I
BUTTON_ERROR
– FMEA Library
Touch button failure
Check U.I.
E9b1
U.I
BUTTON_ERROR
– FMEA short
Touch button failure, the alarm is showed on both display.
Check U.I.
E9C1
U.I
BUTTON_ERROR
– FMEA open
Touch button failure, the alarm is showed on both display.
Check U.I.
4.9 SOFTWARE UPDATE & WIFI
The software update is not possible on the electronic boards. WIFI is not implemented at this moment.
NOTE !
If the filters start to get dirty and limit the fresh air passage, before
emitting an “over heating alarm
E421” the appliance will start to limit the energy emission of the POW, a typical call from a customer
could be “ the appliance is not performing any more” or “ after some time the appliance is not per-
forming”.
Summary of Contents for LIBERO IWOKEC-1P/1ZT
Page 1: ...Service Manual Wok Induction IWOKEC 1P 1ZT Art 406600893 2021 04 ...
Page 15: ...15 LIBERO LINE WOK INDUCTION 3P WOK SA 3PH SZ DI ...
Page 50: ...50 LIBERO LINE WOK INDUCTION ...
Page 51: ...51 LIBERO LINE WOK INDUCTION ...
Page 53: ...53 LIBERO LINE WOK INDUCTION ...
Page 54: ...54 LIBERO LINE WOK INDUCTION ...
Page 56: ...56 LIBERO LINE WOK INDUCTION ...
Page 57: ...57 LIBERO LINE WOK INDUCTION ...
Page 60: ...60 LIBERO LINE WOK INDUCTION ...
Page 62: ...62 LIBERO LINE WOK INDUCTION NOTE E1 21 IS AN INVENTED ALARM JUST FOR ILLUSTRATION PURPOSE ...
Page 68: ...68 LIBERO LINE WOK INDUCTION APPLIANCE CASING ...