51
Mod. CRONOS rev 01
Troubleshooting
translated from the original text
EN
PROBLEM/CAUSE/REMEDY
Problem
Cause
Remedy
Display off and buttons not working
Power failure
Check that the power cable is connected
Faulty connection of display to board
Check that the display and board are connected
properly
Remote control ineffective
Too far from the boiler
Move it closer to the boiler
Remote control batteries
Check and change the batteries
Failed ignition
Excessive pellet build-up in brazier
Clean the brazier
The boiler does not switch on automatically
The resistance does not reach operating tempera-
ture
• Check wiring and fuses
• Replace the resistance if faulty (performed by
assistance)
Resistance damaged or worn
Replace the resistance
The pellets do not drop
IMPORTANT: unplug the appliance before:
• Checking whether any pellets are stuck in the
chute
• Checking whether the auger is blocked
• Checking tightness of the door
Blockage of the boiler
Excessive use without cleaning the brazier
Clean the brazier
Tank empty
Load pellets in the tank
Auger without pellets
Fill the tank and follow the instructions for the first
ignition of the boiler
The boiler blocks due to lack of pellet feed
Technical problem with auger
IMPORTANT: unplug the appliance before:
• Freeing the auger from any obstructions
• Freeing the chute from any obstructions
• Removing pellet dust build-up at the bottom of
the tank
The boiler clogs quickly with irregular combustion
Flue too long or obstructed
• See boiler installation paragraph
• Check that the flue is clean
Pellets too moist
Check the quality of the pellets
Too many pellets in brazier
Contact the authorised assistance centre
Wind against exhaust flow
Check the wind barrier terminal and/or install it
Insufficient exhaust in brazier
• Check that the brazier and air exhaust duct are
positioned properly and clean
• Contact the authorised assistance centre
The type of pellet used was changed
Contact the authorised assistance centre
Smell of smoke in the room
• The boiler goes out
Improper combustion
Contact the authorised assistance centre.
Flue gas extraction fan malfunctioning
Flue installed improperly
tab. 7 list of problems/causes/remedies
Summary of Contents for 0601-0169
Page 2: ......
Page 26: ...26 Mod CRONOS rev 01 Tradu o do texto original Solu o de problemas PT...
Page 52: ...52 Mod CRONOS rev 01 Troubleshooting translated from the original text EN...
Page 78: ...78 Mod CRONOS rev 01 Solution probl mes Traduction des instructions originales FR...
Page 84: ...84 Mod CRONOS rev 01...
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ...Mod CRONOS rev 01...