VER. 001_17.09.2009

The device is designed for 

one-phase installation and 

must be installed in accor

-

dance with standards valid 

in a particular country. The 

device  should  be  connec

-

ted according to the details 

included in this operating manual. Installa

-

tion, connection and control should be car

-

ried out by a qualified electrician staff, who 

act in accordance with the service manual 

and the device functions. Disassembling of 

the device is equal with a loss of guarantee 

and  can  cause  electric  shock.  Before  in

-

stallation make sure the connection cables 

are not under voltage. The cruciform head 

screwdriver 3,5 mm should be used to instal 

the  device.  Improper  transport,  storage, 

and use of the device influence its wrong 

functioning. It is not advisable to instal the 

device in the following cases: if any device 

part is missing or the device is damaged or 

deformed. In case of improper functioning 

of the device contact the producer.

APPEARANCE

FEATURES

TECHNICAL PARAMETERS

DESCRIPTION

The twilight switch WZM-02 is used to 

control  lighting  devices  and  other  ener

-

gy receivers depending on luminous flux 

density. The system switches on the ligh

-

ting at dusk and switches off at dawn. The 

device is equipped with two illuminuous 

flux density ranges where the switching 

on threshold can be adjusted by the user. 

The  system  has  the  continuous  output 

(load) switch on function (ON) , connec

-

ted to output (load) relay terminals, and 

the automatic function (AUTO). External 

luminous flux density sensor SOH with a 

cable of 50 m maximum length enables 

the sensor to be put in a suitable place.

WZM-02

Input (supply) terminals:

L, N

Input rated voltage: 230 V AC

Input voltage tolerance: -15 ÷ +10 %

Nominal frequency:  50 / 60 Hz

Rated power consumption:  35 mA

Input rated indicator: LED green

Zaciski sondy oświetlenia:

IN, IN

Maksymalna długość przewodu sondy: 50 m (MTY 2x 0,5 mm

2

)

Zakres nastaw progu załączenia: two ranges: 1) 0 ÷ 200 lx; 2) 100 ÷ 20.000 lx

Relay indicator:

LED red

Output relay parameters:  1NO/NC - 10 A / 250 V AC1 2500 VA

Number of terminal clamps:  7

Section of connecting cables: from 0,2 to 2,50 mm

2

Ambient temperature range:  from -20 to +45 

o

C

Operating position: free

Mounting:  TH 35 rail (PN-EN 60715)

Protection degree: IP20 (PN-EN 60529)

Protection class:

II

Overvoltage category: 

II

Pollution degree: 

2

Rated impulse withstand voltage: 1 kV (PN-EN 61000-4-5)

Dimensions (height / width / depth): monomodular (17,5 mm) 90x17,5x66 mm

Weight: 0,076 kg

Reference standards: PN-EN 60669-1, PN-EN 60669-2-1

PN-EN 61000-4-2,3,4,5,6,11

●  It allows to switch on or switch off li

-

ghting devices according to the preset 

ambient light level,

●  input rated indicator,

●  relay indicator,

●  illuminuous flux density range choice,

●  adjustment  of  the  switch  on  thre

-

shold,

●  automatic work mode (AUTO) or con

-

tinuous work mode (ON),

●  system  requires  outer  light  inten-

sity  sensor  (e.g.  SOH-01,  SOH-03, 

SOH- 05),

●  resistant  to  momentary  changes  of 

luminous flux density.

Ou

t

pu

t

 

(

l

o

ad

)

 rela

y

 

I

n

pu

t

 

(

suppl

y)

 

t

ermi

n

al 

(

L

)

I

n

pu

t

 

(

suppl

y)

 

t

ermi

n

al 

(

N

)

I

n

pu

t

 ra

t

ed i

n

di

c

a

to

r

Rela

y

 i

n

di

c

a

to

r

Light sensor input

terminals (IN, IN)

terminals (11, 12, 14)

S

w

i

tc

hi

ng

 

on

 

t

hresh

o

ld adjus

t

me

nt

Illuminuous flux density
range (1, 2) choice

Automatic work mode (AUTO) or 
continuous work mode (ON) choice

CAUTION

The symbol stands for selective 

collection of electrical and 

electronic devices. Placing used 

devices with other  waste is not 

allowed