COOPERATION AND OPERATING RANGE
* 1-channel transmitters do not cooperate with roller blind controllers.
CAUTION: The given range concerns open area - an ideal condition without any
natural or artificial obstacles. If there are some obstacles between a transmit-
ter and a receiver, it is advisable to decrease the range according to: wood and
plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to
80 %, metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground
medium and high electrical power lines, radio and television transmitters, GSM
transmitters set close to a device system have also a negative influence on the
range.
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-
01
RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNK-04
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
P-256/8
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
P-257/4 (2)
180 m
200 m
200 m
200 m
200 m
250 m
180 m
250 m
250 m
180 m
250 m
RNM-10
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
RNP-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNP-02
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RNL-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
RTN-01
200 m
200 m
200 m
200 m
200 m
250 m
200 m
250 m
250 m
200 m
250 m
RCR-01
160 m
180 m
180 m
lack*
lack*
200 m
160 m
200 m
200 m
160 m
200 m
RTI-01
160 m
180 m
180 m
180 m
180 m
200 m
160 m
200 m
200 m
160 m
200 m
RXM-01
230 m
250 m
250 m
250 m
250 m
300 m
200 m
300 m
300 m
230 m
300 m
RADIO TRANSMITTERS DELETION
Press PROG push-button of ROP-01 device for a longer time.
After 5 seconds LED red diode switches on (signal pulsates) and then it switches
off.
Release the push-button in ROP-01 - MEMORY IS DELETED.
TIME PROGRAMMING
Press PROG push-button of ROP-01 device for a longer time till LED red diode
switches on (constant signal). Next release PROG push-button. Wait (for about
5 seconds) till LED red diode switches on (first signal pulsates, next the signal is
constant).
Press PROG push-button of ROP-01 device and then release it. LED red diode
switches off and then switches on (signal pulsates). Every LED diode pulse
equals 1 second.
After the adjusted time is finished (the number of LED red diode flashes) press
PROG push-button and then release it - TIME IS ADDED.
Maximum time is 18 hours.
UNIVERSAL WIRELESS CONTROL SET
RZB-05
TECHNICAL DATA
P-257/2
ROP-01
Input (supply) terminals:
-
L, N
Input rated voltage:
3 V (battery CR2032)
230 V~
Battery life:
3 ÷ 5 years
-
Input voltage tolerance:
-
-15 ÷ +10 %
Nominal frequency:
-
50 / 60 Hz
Nominal power consumption:
-
0,29 W
Number of operation modes:
-
5
Number of channels:
2
1
Transmission:
radio 868,32 MHz
Transmission way:
unidirectional
Coding:
addressing transmission
Maximum number of transmitters:
-
32
Range: up to 250 m in the open air up to 230 m in the open air
Time adjustment:
-
1 s ÷ 18 hours (every
second)
Optical signalling:
LED red diode
Relay output clamps:
-
12, 11, 14
Relay contacts parameters:
-
1NO/NC 5A / 250V AC AC1
1250 VA
Number of terminal clamps:
-
5
Section of connecting cables:
-
up to 2,5 mm
2
Ambient temperature range:
-10 ÷ +55
o
C
Operating position:
free
Mounting:
-
installation cable box Ø60
mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III
II
Overvoltage category:
-
II
Pollution degree:
2
Surge voltage:
-
1 kV (EN 61000-4-5)
Dimensions:
74 x 33 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,020 kg
0,043 kg
Reference standard:
PN-ETSI EN 300 220-1
PN-ETSI EN 300 220-2
PN-EN 60669, PN-EN
60950, PN-EN 6100