RZB-03 WIRELESS CONTROL SET
– ROLLER BLINDS CONTROL
MANUAL INSTRUCTION
ZAMEL
Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04
www.zamelcet.com
, e-mail: [email protected]
VER. 003_20.05.2011
APPEARANCE
The device is designed for
single-phase installation and
must be installed in accord-
ance with standards valid in
a particular country. The de-
vice should be connected ac-
cording to the details included
in this operating manual. Installation, connection
and control should be carried out by a qualified
electrician staff, who act in accordance with the
service manual and the device functions.
In case of casing dismantling an electric shock
may occur, and the guarantee is lost then. Before
installation make sure the connection cables are
not under voltage. The cruciform head screwdriv-
er 3,5 mm should be used to instal the device. Im-
proper transport, storage, and use of the device
influence its wrong functioning. It is not advisable
to instal the device in the following cases: if any
device part is missing or the device is damaged
or deformed. In case of improper functioning of
the device contact the producer.
CAutioN!
FEAtuRES
tECHNiCAL DAtA
DESCRiPtioN
● Complete set of wireless control
(2–channel button radio transmitter
RNK-02 and radio roller blinds controller
SRP-02),
● used in wired and wireless control of
roller blind, sunblind and gate drives,
(electric motors of 230V AC),
● wired local control inputs,
● easily installed in Ø60 mm junction box,
● energy-saving device, possibility of con-
stant work,
● two comfort modes - upper and bottom
(memory of roller blind height level),
● possibility of cooperation with any roler
blind switch (which is not equipped in
backlight elements)
SRP-02 controller is used to control
roller blind drives with 230V AC motor with
a limit switch. The device realises roller
blinds local and central control functions
and it has the possibility of comfort mode
adjustment. Comfort modes are used to
adjust roller blinds position (height level)
and to memorise the height level. Central
mode is used in case of a totally closed
or opened roller blind or a group of roller
blinds with different position level.
RNK-02
SRP-02
Input (supply) terminals:
-
L, N
Input rated voltage:
3 V DC (CR2032 battery)
230 V AC
Battery life:
3 ÷ 5 years
-
Input voltage tolerance:
-
+10 ÷ -15 %
Nominal frequency:
-
50 / 60 Hz
Nominal power consumption:
-
0,4 W („stand-by” mode) / 0,7 W (roller blind movement)
Transmission:
radio 868,32 MHz
Coding way:
unidirectional
Coding:
addressing transmission
Maximum number of remote controls:
-
32
Range:
up to 250 m in the open area
Maximum movement time of roller blind:
-
120 sec
Maximum time of roller blind movement:
-
1 ÷ 120 sec (every 0,1 sec)
Optic signalling of transmitter’s operation:
LED red diode
Local control terminals:
-
LOCAL (up), (down)
Motor power supply terminals:
-
(up), (down)
Relay contact parameters:
-
2NO 5A/250V AC AC3 1250 VA
Number of terminal clamps:
-
6
Section of connecting cables:
-
up to 2,5 mm
2
Ambient temperature range:
-10 ÷ +55
o
C
Operating position:
free
Casing mounting: wall plugs, double-sided adhesive tape
installation cable box Ø60 mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III
II
Overvoltage category:
-
II
Pollution degree:
2
Surge voltage:
-
1 kV (EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,038 kg
0,039 kg
Reference standard:
ETSI EN 300 220-1
ETSI EN 300 220-2
EN 60669, EN 60950,
EN 61000
The symbol means selective
collecting of electrical and electronic
equipment.
It is forbidden to put the used
equipment together with other waste
Optic signalling of receiver’s operation
Programming push-button
Local wired control terminals
(upward movement , downward movement )
Roller blind motor terminals
(upward movement , downward movement )
Input (supply) terminals (L, N)
Optic signalling
of transmitter’s operation
Push-button
CoNNECtioN
APPLiCAtioN
LOCAL
LOCAL
SRP-02 MouNtiNG
1. Disconnect power supply by the phase fuse,
the circuit-breaker or the switch-disconnector
combined to the proper circuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measure
equipment.
3. Connect the cables with the terminals in ac-
cordance with the installing diagram.
4. Install SRP-02 device in installation cable box.
5. Switch on the power supply from the mains.
RNK-02 FuNCtioNiNG, MouNtiNG
By pressing the button, the transmitter sends a
signal with 868,32 MHz frequency which controls
EXTA FREE receivers.
Device programming
procedure (adding a transmitter to a receiv-
er’s memory) is described in particular EXtA
FREE manual instructions.
The device range
(up to 250 m depending on a receiver) can be in-
creased by means of a retransmitter or few RTN-
01 retransmitters. The device can be mounted in
any place by means of double-sided adhesive
tape or two wall plugs (5x(3x30) mm.
Mounting by means of wall plugs:
1. Remove the button - to do it press the button
on one side, and on the other side put a screw-
driver into a slot and lift up the button.
2. Find a place on the wall to mount the transmit-
ter, make two holes corresponding mounting
holes from the transmitter’s base.
3. Set wall plugs in the holes.
4. Fix the base by means of screwing screws into
wall plugs.
5. Place the button again.
BAttERY CHANGE
Battery discharge status is signalled by sev-
eral LED red diode flashes during transmis-
sion time.
1. Remove the button (mounting - point 1).
2. By means of a screwdriver lever up the printed-
circuit board releasing the bottom latch and re-
move it from the base.
3. Remove the battery from the latch.
4. Mount a new battery.
Watch battery polari-
sation marked on the latch. Wrong battery
mounting may cause device damage.
5. Put the removed printed-circuit board back in
the base.
6. Put back the button.
CAutioN:
While changing the battery, it is suggested to
press any of the buttons for about 5 seconds
before putting it into a latch. Next press trans-
mission button several times to check its op-
eration. if the transmitter does not work prop-
erly repeat the battery change procedure.
WARRANtY CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-
TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting
from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device
in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
Salesman stamp and signature, date of sale
CAutioN:
Local switches connection (LoCAL) is optional.
Radio flush dimmer RNK-02 operating roller
blind controller SRP-02 (roller blind opening /
closing). The above mentioned transmitter can
be added to any number of receivers.
The ZAMEL company
devices which are
characterised with this sign
can cooperate
with each other.