Zamel exta SRP-01/M Manual Instruction Download Page 2

TIME COURSES

MOUNTING

FUNCTIONING

CONNECTION

APPLICATION

1. Disconnect power supply by the phase 

fuse, the circuit-breaker  or the switch-dis-

connector combined to the proper circuit.

2. Check if there is no voltage on connection 

cables by means of a special measure  

equipment.

3. Connect  the cables with the terminals in 

accordance with the installing diagram.

4. Install SRP-01/M device in installation ca-

ble box.  

5. Switch on the power supply from the 

mains.

The controller realises operations of: rais-

ing, lowering or stopping the roller blind 

equipped in one-phase motor of 230V AC. 

Pressing the local control push-button once 

causes the roller blind moves in a chosen di-

rection, another push-button pressing caus-

es the roller blind stops. Pressing the central 

control push-button causes the roller blind 

moves (raising or lowering) independently of 

the level it is in.

Upper comfort adjustments:

1. press local control push-button (LOCAL  ),

2. when the roller blind is totally open, press 

PROG push-button which is placed on the 

SRP-01/M casing,

3. the roller blinds automatically lowers - if it 

is in the adjusted „comfort place”  press 

PROG push-button again,

4. using local control push-button (LOCAL  ) 

raise the roller blind completely (upper level 

- completely open),

5. press longer the local control push-button 

(LOCAL  ) - the roller blind lowers and 

stops exactly in the „comfort place”.

Lower comfort adjustments:

1. press local control push-button (LOCAL  ),

2. when the roller blind is at the bottom (to-

tally closed), press PROG push-button,

3. the roller blinds automatically raises - if 

it is in the adjusted „comfort place” press 

PROG push-button again,

4. using local control push-button (LOCAL  ) 

lower the roller blind completely (lower level 

- completely closed),

5. press longer the local control push-button 

(LOCAL  ) - the roller blind raises and 

stops exactly in the „comfort place”.

Roller blinds control system is realised by means of SRP-01/M roller blinds controllers. One 

controller can be used only for one roller blind. Every controller can be connected to blind 

switches of local control and has central control inputs connections, which enable closing 

or opening a group of roller blinds by means of SRP-03 central flush roller blinds control-

ler operated by wireless P-256/8 remote control. Blind switches can not be equipped with 

backlight. 

D

  - movement down  

G

  - movement up

LOCAL

LOCAL

CENTRAL

CENTRAL

WARRANTY CARD

There is 24 months guarantee on the product

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: 

a)  mechanical defects resulting from transport, loading / unloading or other circumstances; 

b)  defects resulting from incorrect installation or operation of ZAMEL products;

c)  defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the 

correct operation of products sold;

d)  defects resulting from force majeure or other aleatory events for which ZAMEL is not liable;

e)  power supply (batteries) to be equipped with a device in the moment of sale (if they appear). 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy 

between the goods and the contract.

Salesman stamp and signature, date of sale

LOCAL

CONTROL

SRP-01/M

SRP-03

SRP-01/M

LOCAL

CONTROL

CENTRAL CONTROL

LOCAL 

CENTRAL 

LOCAL 

CENTRAL 

Reviews: