background image

2-CHANNEL RADIO MODULAR RECEIVER ROM-10

 

MANUAL INSTRUCTION

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

VER. 003_20.05.2011

APPEARANCE

TECHNICAL DATA

ROM-10

Input (supply) terminals: L, N

Input rated voltage: 230V AC

Input voltage tolerance: -15 ÷ +10 %

Nominal frequency: 50 / 60 Hz

Nominal power consumption: 0,55 W

Optic signalling of power supply: LED green diode

Number of operation modes: 5

Number of channels: 2

Transmission: radio 868,32 MHz

Coding way: unidirectional

Coding: addressing transmission

Maximum number of remote controls: 32

Range: up to 300 m in the open area

Time adjustment: 1 sec. ÷ 18 hours (every second)

Optic signalling of relay status: 2 x LED red diode

2 x LED red diode 12, 11, 14, 24, 21, 22

Relay contact parameters: 2NO/NC 8A / 250V~ AC1 2000 VA

Ambient temperature range: -10 ÷ +55 

o

C

Section of connecting cables: do 2,5 mm

2

Operating position: free

Casing mounting: TH-35 rail (according to EN 60715)

Casing protection degree: IP20 (EN 60529)

Protection level: II

Overvoltage category: II

Pollution degree: 2

Surge voltage: 1 kV (EN 61000-4-5)

Dimensions: monomodular casing (17,5 mm) 90 x 17,5 x 66 mm

Weight: 0,087 kg

Reference standard: EN 60669, EN 60950, EN 61000

The device is designed for 

single-phase installation and 

must be installed in accord-

ance with standards valid in 

 

a particular country. The device 

should be connected according 

to the details included in this 

operating manual. Installation, connection and 

control should be carried out by a qualified electri-

cian staff, who act in accordance with the service 

manual and the device functions. 

In case of casing dismantling an electric shock 

may occur, and the guarantee is lost then. Before  

installation make sure the connection cables are 

not under voltage. The cruciform head screwdriver 

3,5 mm should be used to instal the device. Im-

proper transport, storage, and use of the device 

influence its wrong functioning. It is not advisable 

to instal the device in the following cases:  if any 

device part is missing or the device is damaged 

or deformed. In case of  improper functioning  

of the device contact the producer.

CAuTIoN!

FEATuRES

DESCRIPTIoN

● cooperation  with  wireless  EXTA  FREE 

system transmitters, 

● 2-channel  radio  receiver  mounted  on  

a TH-35 rail in a distribution board,

● five operation modes: switching on mode, 

switching off, monostable, bistable, time,

● two  output  relays  8A  (changeover  

contacts),

● wide range of operation (up to 300 m),
● power supply and relay operation are opti-

cally signalled,

● integration  possibility  with  wired  control 

systems (e.g. exta home automation),

● connection possibility of ANT-01 antenna 

mounted not in the distribution board,

● possibility of widening operation range by 

means of RTN-01 retransmitter.

2-channel radio modular receiver ROM-

10 can be mounted in distribution boards on 

the TH-35 rail and can realise radio control 

functions  using  any  of  EXTA  FREE  system 

transmitters. Any electric system realising 

radio system functions can be connected to 

the device relay output (e.g. wired devices of 

EXTA home automation, relay-contactor sys-

tems and others).

The symbol means selective 

collecting of electrical and electronic 

equipment.  

It is forbidden to put the used 

equipment together with other waste.

Optic signalling of input voltage

Optic signalling of relay 1 status (channel 1)
Optic signalling of relay 2 status (channel 2)

Antenna’s socket

Programming push-buttons (PROG 1, PROG 2)

Input (supply) terminals (L, N)

Relay output terminals (12, 11, 14, 24, 21, 22)

Antenna

CoNNECTIoN

APPLICATIoN

Radio modular receiver 

ROM-10 operates as 

a receiver of P-257/4 

4-channel remote control 

(control of lighting 

operation in front of 

and inside the garage). 

Additionally P-257/4 

remote control can 

control operation of ROB-

01/12-24V radio gate 

controller.

CAPACITY

1000W

250W

500W

375W

MouNTING

1. Disconnect power supply by the phase 

fuse, the circuit-breaker  or the switch-

disconnector combined to the proper 

circuit.

2. Check if there is no voltage on 

connection cables by means of 

 

a special measure equipment.

3. Connect  the cables with the terminals in 

accordance with the installing diagram.

4. mount  ROM-10 device on a TH-35 rail.

5. 

Switch on the power supply from 

 

the mains.

WARRANTY CARD

There is 24 months guarantee on the product

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances  

b) defects resulting from incorrect installation or operation of ZAMEL products; c) defects resulting from any changes made by CUS-

TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold; d) defects resulting 

from force majeure or other aleatory events for which ZAMEL is not liable; e) power supply (batteries) to be equipped with a device 

in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy 

between the goods and the contract.

Salesman stamp and signature, date of sale

The ZAMEL company devices 

which are characterised with 

this sign can cooperate with 

each other.

Reviews: