3
3. Specifications
3) ZM1000-ARX Electrical & Physical Specifications
AC Input Range
Voltage
100~240VAC ±10%
Vout
Output Load Rating
Combined
Power
Frequency
50Hz ~ 60㎐
±3
I
min
I
max
I
peak
AC Input Current
100VAC
12-6A
+3.3V
0.1A
25A
120W
1000W
240VAC
+5V
0.2A
22A
PFC Type
Active PFC
+12V
0.2A
83A
996W
Power Factor Correction
Max 99%
-12V
0.0A
0.3A
3.6W
Inrush Current Limit
(@ Cold Start at 25℃)
100VAC
Max 50A
+5VSB
0.0A
2.5A
12.5W
240VAC
Ambient Temperature
Efficiency
Max 94% @ 230VAC, Typical load
Operation
0 ~ +40℃
DC Output Voltage
Regulation
Vout
Regulation Range
At
Full
Load
Storage
-20 ~ +70℃
+3.3VDC
±5%
+3.14 ~ +3.47V
Ambient Humidity
+5VDC
±5%
+4.75 ~ +5.25V
Operation
5% ~ 95% RH
+12VDC
±5%
+11.4 ~ +12.6V
Storage
5% ~ 95% RH
-12VDC
±10%
-10.8 ~ -13.0V
Dimensions
180(D) x 150(W) x 86(H)mm
+5VSB
±5%
+4.75 ~ +5.25V
Weight
3.05kg
DC Output Ripple
& Noise
Vout
Standard Range
At
Full
Load
Protection Functions
+3.3VDC
50mV
Over-Current Protection (OCP)
+5VDC
50mV
Over-Voltage Protection (OVP)
+12VDC
120mV
Under-Voltage Protection (UVP)
-12VDC
120mV
Short-Circuit Protection (SCP)
+5VSB
50mV
Over-Power Protection (OPP)
Over-Temperature Protection (OTP)
4) ZM1200-ARX Electrical & Physical Specifications
AC Input Range
Voltage
115-240VAC
±10%
Vout
Output Load Rating
Combined
Power
Frequency
50Hz ~ 60㎐
±3
I
min
I
max
I
peak
AC Input Current
115VAC
12.6-6A(EU) /
12-6A(North America)
+3.3V
0.1A
25A
120W
1200W
240VAC
+5V
0.2A
22A
PFC Type
Active PFC
+12V
0.2A
100A
1200W
Power Factor Correction
Max 99%
-12V
0.0A
0.3A
3.6W
Inrush Current Limit
(@ Cold Start at 25℃)
115VAC
Max 50A
+5VSB
0.0A
2.5A
12.5W
240VAC
Ambient Temperature
Efficiency
Max 94% @ 230VAC, Typical load
Operation
0 ~ +40℃
DC Output Voltage
Regulation
Vout
Regulation Range
At
Full
Load
Storage
-20 ~ +70℃
+3.3VDC
±5%
+3.14 ~ +3.47V
Ambient Humidity
+5VDC
±5%
+4.75 ~ +5.25V
Operation
5% ~ 95% RH
+12VDC
±5%
+11.4 ~ +12.6V
Storage
5% ~ 95% RH
-12VDC
±10%
-10.8 ~ -13.0V
Dimensions
180(D) x 150(W) x 86(H)mm
+5VSB
±5%
+4.75 ~ +5.25V
Weight
3.1kg
DC Output Ripple
& Noise
Vout
Standard Range
At
Full
Load
Protection Functions
+3.3VDC
50mV
Over-Current Protection (OCP)
+5VDC
50mV
Over-Voltage Protection (OVP)
+12VDC
120mV
Under-Voltage Protection (UVP)
-12VDC
120mV
Short-Circuit Protection (SCP)
+5VSB
50mV
Over-Power Protection (OPP)
Over-Temperature Protection (OTP)
English